scholarly journals Laser Photothermoacoustic Heterodyned Lock-in Depth Profilometry in Turbid Tissue Phantoms

2021 ◽  
Author(s):  
Ying Fang ◽  
Andreas Mandelis ◽  
Gloria Spirou ◽  
I. Alex Vitkin ◽  
William M. Whelan

Frequency-domain correlation and spectral analysis photothermoacoustic FD-PTA imaging is a promisingnew technique, which is being developed to detect tumor masses in turbid biological tissue. Unlike conventional biomedical photoacoustics which uses time-of-flight acoustic information induced by a pulsed laser to indicate the tumor size and location, in this research, a new FD-PTA instrument featuring frequency sweep chirp and heterodyne modulation and lock-in detection of a continuous-wave laser source at 1064 nm wavelength is constructed and tested for its depth profilometric capabilities with regard to turbid media imaging. Owing to the linear relationship between the depth of acoustic signal generation and the delay time of signal arrival to the transducer, information specific to a particular depth can be associated with a particular frequency in the chirp signal. Scanning laser-fluence modulation frequencies with a linear frequency sweep method preserves the depth-to-delay time linearity and recovers FD-PTA signals from a range of depths. Combining with the depth information carried by the back-propagated acoustic chirp signal at each scanning position, one could rapidly generate subsurface three-dimensional images of the scanning area at optimal signal-to-noise ratios and low laser fluences, a combination of tasks that is difficult or impossible by use of pulsed photoacoustic detection. In this paper, results of PTA scans performed on tissue mimicking control phantoms with various optical, acoustical, and geometrical properties are presented. A mathematical model is developed to study the laser-induced photothermoacoustic waves in turbid media. The model includes both the scattering and absorption properties of the turbid medium. A good agreement is obtained between the experimental and numerical results. It is concluded that frequency domain photothermoacoustics using a linear frequency sweep method and heterodyne lock-in detection has the potential to be a reliable tool for biomedical depth-profilometric imaging.

2021 ◽  
Author(s):  
Ying Fang ◽  
Andreas Mandelis ◽  
Gloria Spirou ◽  
I. Alex Vitkin ◽  
William M. Whelan

Frequency-domain correlation and spectral analysis photothermoacoustic FD-PTA imaging is a promisingnew technique, which is being developed to detect tumor masses in turbid biological tissue. Unlike conventional biomedical photoacoustics which uses time-of-flight acoustic information induced by a pulsed laser to indicate the tumor size and location, in this research, a new FD-PTA instrument featuring frequency sweep chirp and heterodyne modulation and lock-in detection of a continuous-wave laser source at 1064 nm wavelength is constructed and tested for its depth profilometric capabilities with regard to turbid media imaging. Owing to the linear relationship between the depth of acoustic signal generation and the delay time of signal arrival to the transducer, information specific to a particular depth can be associated with a particular frequency in the chirp signal. Scanning laser-fluence modulation frequencies with a linear frequency sweep method preserves the depth-to-delay time linearity and recovers FD-PTA signals from a range of depths. Combining with the depth information carried by the back-propagated acoustic chirp signal at each scanning position, one could rapidly generate subsurface three-dimensional images of the scanning area at optimal signal-to-noise ratios and low laser fluences, a combination of tasks that is difficult or impossible by use of pulsed photoacoustic detection. In this paper, results of PTA scans performed on tissue mimicking control phantoms with various optical, acoustical, and geometrical properties are presented. A mathematical model is developed to study the laser-induced photothermoacoustic waves in turbid media. The model includes both the scattering and absorption properties of the turbid medium. A good agreement is obtained between the experimental and numerical results. It is concluded that frequency domain photothermoacoustics using a linear frequency sweep method and heterodyne lock-in detection has the potential to be a reliable tool for biomedical depth-profilometric imaging.


Sensors ◽  
2021 ◽  
Vol 21 (2) ◽  
pp. 670
Author(s):  
Wijayanti Dwi Astuti ◽  
Hiraku Matsukuma ◽  
Masaru Nakao ◽  
Kuangyi Li ◽  
Yuki Shimizu ◽  
...  

This paper proposes a new optical angle measurement method in the optical frequency domain based on second harmonic generation with a mode-locked femtosecond laser source by making use of the unique characteristic of the high peak power and wide spectral range of the femtosecond laser pulses. To get a wide measurable range of angle measurement, a theoretical calculation for several nonlinear optical crystals is performed. As a result, LiNbO3 crystal is employed in the proposed method. In the experiment, the validity of the use of a parabolic mirror is also demonstrated, where the chromatic aberration of the focusing beam caused the localization of second harmonic generation in our previous research. Moreover, an experimental demonstration is also carried out for the proposed angle measurement method. The measurable range of 10,000 arc-seconds is achieved.


2013 ◽  
Vol 558 ◽  
pp. 76-83 ◽  
Author(s):  
Yun Kyu An ◽  
Ji Min Kim ◽  
Hoon Sohn

This study proposes a new nondestructive evaluation methodology named laser lock-in thermography (LLT) for fatigue crack detection. LLT utilizes a high power continuous wave (CW) laser as a heat generation source for lock-in thermography instead of commonly used flash and halogen lamps. The advantages of the proposed LLT method are that (1) the laser heat source can be positioned at an extended distance from a target structure thank to the directionality and low energy loss of the laser source, (2) thermal image degradation due to surrounding temperature disturbances can be minimized because of high temperature gradient generated by the laser source and (3) a large target surface can be inspected using a scanning laser heat source. The developed LLT system is composed of a modulated high power CW laser, galvanometer and infrared camera. Then, a holder exponent-based data processing algorithm is proposed for intuitive damage evaluation. The developed LLT is employed to detect a micro fatigue crack in a metal plate. The test result confirms that 5 μm (or smaller) fatigue crack in a dog-bone shape aluminum plate with a dimension of 400 x 140 x 3 mm3 can be detected.


2005 ◽  
Vol 30 (11) ◽  
pp. 1354 ◽  
Author(s):  
David J. Cuccia ◽  
Frederic Bevilacqua ◽  
Anthony J. Durkin ◽  
Bruce J. Tromberg

Sign in / Sign up

Export Citation Format

Share Document