scholarly journals Investigation of Static Laterally Loaded Pile in Layered Sandy Soil

2013 ◽  
Vol 8 (1-2) ◽  
pp. 83-88 ◽  
Author(s):  
SMH Uddin ◽  
MN Islam

Investigation of the static lateral load resistance of pile on layered sandy soil was made by laboratory model test on single pile. The experiment was carried out with variable diameter and variable embedded length of pile on sandy soil. In this study, model pile was single pile which satisfies the Meyerhof’s Relative Stiffness limit of pile for flexible pile. Single pile embedded length, L=0.46m, 0.609m, 0.762m for pile diameter, d=0.013m, 0.019m, 0.026m, respectively. And for surcharge condition embedded length of single pile, L=0.609m and surcharge of pressure, P=3369.55Kg/m3, P=6739.1 Kg/m3 and P=13478.20Kg/m3 for each diameter and for saturated condition of pile diameter, d=0.013m. These experiments were conducted with local sand of Rajshahi region and domar sand; available in Bangladesh. Lateral static loads were applied in the single by a static lateral load set up arrangement. Due to the static lateral load the pile was deflected. The load-displacement response, ultimate resistance of pile has been qualitatively and quantitatively investigated in the experiment. The lateral resistance of pile obtains by experiment and the ultimate lateral load resistances obtained by analytical methods were compared. The load displacement curves are similar and non-linear. Lateral failure at a pile head displacement from 8 to 10, 7 to 9 and 6 to 8mm for single pile of d= 0.013m, 0.019m and 0.026m, respectively. In the case of saturated condition of sand a pile head displacement 15mm for single of d=0.013m. It observed that the failure load was the point at which the curve exhibits a pick or maintains continuous displacement increase with no further increase in lateral resistance. DOI: http://dx.doi.org/10.3329/jsf.v8i1-2.14630 J. Sci. Foundation, 8(1&2): 83-88, June-December 2010

2009 ◽  
Vol 13 (3) ◽  
pp. 143-152 ◽  
Author(s):  
Jinoh Won ◽  
Fred H. Kulhawy

2014 ◽  
Vol 51 (4) ◽  
pp. 381-393 ◽  
Author(s):  
Ahmed M.A. Nasr

Large lateral loads may act on pile foundation supporting structures, such as bridge abutments, retaining walls, and structures subjected to wind–earthquake loads. A pile with fins is a newly developed type of pile foundation that is capable of supporting large lateral loads. In the present study an attempt is made to evaluate the improvement in lateral capacity of a pile with fins mounted close to the pile head. Small-scale model tests and a numerical study using finite element analysis were performed on regular piles without (fins) and piles with fins. These piles were installed in sand of different relative densities (Dr = 35% and 78%). The investigations were carried out by varying the length, width, and shape of the fins, and type of pile. Results reveal that there is a significant increase in lateral resistance of the piles after mounting the fins close to the pile head. The increase in lateral resistance gained by placing fins on a pile varies with geometries of the pile and fins. The lateral resistance increases with the increase in length of the fins until the fin’s length is equal to 0.4 of the pile length. Based on the results of the laboratory model and numerical analysis, critical values of fin parameters for maximum improvement are suggested. The agreement between observed and computed results is found to be reasonably good in terms of ultimate lateral load and fin efficiency. A comparison between the model results and the prototype-scale results is also studied.


2015 ◽  
Vol 773-774 ◽  
pp. 1397-1401 ◽  
Author(s):  
Mahdy Khari ◽  
Khairul Anuar Kassim ◽  
Payman Alimohammadi

Piles are generally required to transfer load from a superstructure through weak or compressible strata, or through water, on to stiffer and less compressible soils and rock. The pile behavior is very important in Soil-Pile interaction (as known Kinematic Interaction) so that grouped and single pile behavior differs owing to the impacts of the pile-to-pile interaction. In this research presents a series of experimental investigations carried out on single and group pile subjected to monotonic lateral loadings. The aluminum model piles were tested in the different relative densities in Johor Bahru sand. The sand samples were prepared by using the newly designed Mobile Pluviator adopted the air pluviation method. The different configurations of model pile groups for embedded length-to-diameter ratio equal to 32 into loose and dense sand spacing from 3 to 6 pile diameter (D) were conducted. The ultimate lateral load is increased 53% in increasing of s/d from 3 to 6 owing to effects of sand relative density. A ratio of s/D more than 6d is large enough to eliminate the pile-to-pile interaction and the group effects. It may be more in the loose sand.


Author(s):  
Bengt Fellenius

On April 4, 2018, 209 days after driving, a static loading test was performed on a 50 m long, strain-gage instrumented, square 275-mm diameter, precast, shaft-bearing (“floating”) pile in Göteborg, Sweden. The soil profile consisted of a 90 m thick, soft, postglacial, marine clay. The groundwater table was at about 1.0 m depth. The undrained shear strength was about 20 kPa at 10 m depth and increased linearly to about 80 kPa at 55m depth. The load-distribution at the peak load correlated to an average effective stress beta-coefficient of 0.19 along the pile or, alternatively, a unit shaft shear resistance of 15 kPa at 10 m depth increasing to about 65 kPa at 50 m depth, indicating an α-coefficient of about 0.80. Prior to the test, geotechnical engineers around the world were invited to predict the load-movement curve to be established in the test—22 predictions from 10 countries were received. The predictions of pile stiffness, and pile head displacement showed considerable scatter, however. Predicted peak loads ranged from 65% to 200% of the actual 1,800-kN peak-load, and 35% to 300% of the load at 22-mm movement.


2016 ◽  
Vol 78 (5-5) ◽  
Author(s):  
J. D. Nyuin ◽  
M. J. Md Noor ◽  
Y. Ashaari ◽  
C. Petrus ◽  
A. Albar

Conventional analysis and design of shallow foundation are based on the assumption that the soil is under fully saturated condition. However, shallow foundations are typically constructed near the ground surface where the soil is under partially saturated condition. Therefore, more research to investigate the behaviour of shallow foundation in unsaturated soil is very essential in order to aid engineers in making good analysis and design. This paper presents a series of laboratory footing tests conducted on unsaturated sandy soil. A specially designed test tank was fabricated for the test. Square footings of two different sizes (100 mm x 100 mm and 150 mm x150 mm) were used and loaded on Rawang sand which has residual suction value of 10 kPa. The measured values of matric suction of the soil in the test tank were in the range of 0 to 30 kPa. Based on the results, it was observed that bearing capacities of shallow foundation under fully saturated condition were the lowest compared to soil under unsaturated conditions. The highest values were measured at matric suction equals to residual suction (i.e 10 kPa). Furthermore, the relationship between the bearing capacities of shallow foundation with the matric suction was observed to be non-linear.    


Sign in / Sign up

Export Citation Format

Share Document