Bulk water treatment unit performance: For the cameras or the community?

Waterlines ◽  
2012 ◽  
Vol 31 (1-2) ◽  
pp. 53-66 ◽  
Author(s):  
Richard Luff ◽  
Caetano Dorea
2020 ◽  
Vol 0 (2) ◽  
pp. 21-25
Author(s):  
Nikolay Dubenok ◽  
Andrey Novikov ◽  
Sergei Borodychev ◽  
Maria Lamskova

At the stage of water treatment for irrigation systems, the efficiency capture coarse and fine mechanical impurities, as well as oil products and organic compounds affects the reliability of the equipment of the irrigation network and the safety of energy exchange processes in irrigated agricultural landscapes. The violation of work irrigation system can cause disruptions in irrigation schedules of agricultural crops, crop shortages, degradation phenomena on the soil and ecological tension. For the combined irrigation system, a water treatment unit has been developed, representing a hydrocyclone apparatus with a pipe filter in the case. For the capacity of 250 m3/h the main geometrical dimensions of hydrocyclone have been calculated. To organize the capture petroleum products and organic compounds, it has been proposed a modernization of a hydrocyclone unit, consisting in dividing the cylindrical part of the apparatus into two section. The first is section is for input irrigation water, the second one is for additional drainage of clarified irrigation water after sorption purification by the filter, placed on the disk and installed coaxially with the drain pipe and the pipe filter.


2020 ◽  
Vol 20 (6) ◽  
pp. 2106-2118
Author(s):  
Kassim Chabi ◽  
Jie Zeng ◽  
Lizheng Guo ◽  
Xi Li ◽  
Chengsong Ye ◽  
...  

Abstract People in remote areas are still drinking surface water that may contain certain pollutants including harmful microorganisms and chemical compounds directly without any pretreatment. In this study, we have designed and operated a pilot-scale drinking water treatment unit as part of our aim to find an economic and easily operable technology for providing drinking water to people in those areas. Our small-scale treatment unit contains filtration and disinfection (UV–C irradiation) stages to remove pollutants from source water. The water quality index was determined based on various parameters such as pH, temperature, dissolved oxygen, nitrate, nitrite, ammonium, phosphorus, dissolved organic carbon and bacteria. Water and media samples after DNA extraction were sequenced using Illumina MiSeq throughput sequencing for the determination of bacterial community composition. After the raw water treatment, the reduction of bacteria concentration ranged from 1 to 2 log10. The average removal of the turbidity, ammonium, nitrite, phosphorus and dissolved organic carbon reached up to 95.33%, 85.71%, 100%, 28.57%, and 45%, respectively. In conclusion, multiple biological stages in our designed unit showed an improvement of the drinking water quality. The designed drinking treatment unit produces potable water meeting standards at a lower cost of operation and it can be used in remote areas.


2019 ◽  
Vol 19 (7) ◽  
pp. 2098-2106
Author(s):  
Chelsea W. Neil ◽  
Yingying Zhao ◽  
Amy Zhao ◽  
Jill Neal ◽  
Maria Meyer ◽  
...  

Abstract Source water quality can significantly impact the efficacy of water treatment unit processes and the formation of chlorinated and brominated trihalomethanes (THMs). Current water treatment plant performance models may not accurately capture how source water quality variations, such as organic matter variability, can impact treatment unit processes. To investigate these impacts, a field study was conducted wherein water samples were collected along the treatment train for 72 hours during a storm event. Systematic sampling and detailed analyses of water quality parameters, including non-purgeable organic carbon (NPOC), UV absorbance, and THM concentrations, as well as chlorine spiking experiments, reveal how the THM formation potential changes in response to treatment unit processes. Results show that the NPOC remaining after treatment has an increased reactivity towards forming THMs, and that brominated THMs form more readily than chlorinated counterparts in a competitive reaction. Thus both the reactivity and quantity of THM precursors must be considered to maintain compliance with drinking water standards, a finding that should be incorporated into the development of model-assisted treatment operation and optimization. Advanced granular activated carbon (GAC) treatment beyond conventional coagulation–flocculation–sedimentation processes may also be necessary to remove the surge loading of THM-formation precursors during a storm event.


2014 ◽  
Vol 4 (4) ◽  
pp. 709-713 ◽  
Author(s):  
Caetano C. Dorea ◽  
Vincent Jalaber

Humanitarian water treatment interventions vary from package bulk ‘kits’ to household (point-of-use) options. Whereas the former can be perceived to be too complex to operate, the latter, whilst relatively simple and effective, has logistical requirements that may hinder its application during relief operations. This study evaluates the potential of a semi-decentralised water treatment approach for humanitarian emergencies. Its performance was evaluated against the relevant water quality treatment objectives (The Sphere Project) under controlled laboratory conditions using a synthetic test water. Results revealed that whilst the recommended minimum free chlorine residual levels were not attained (possibly due to high chlorine demand of test water), all other treatment objectives were within desired values, namely: <1 colony-forming unit (cfu)/100 mL with regards to thermotolerant (faecal) coliforms and <5 NTU (nephelometric turbidity units) for treated water turbidity. Given the performance of the semi-decentralised approach tested here, it could be expected to attain all treatment objectives when tested in natural surface waters. It has the potential to bridge the gap between centralised (i.e. bulk water treatment kits) and fully decentralised (i.e. household) water supply strategies.


2018 ◽  
Vol 7 (1) ◽  
Author(s):  
Nusa Idaman Said ◽  
Arie Herlambang

Contamination of rivers has reached an alarming level, especially in the rivers passing through major cities, agricultural areas and industrial areas. Among the contaminants that often appear dominant and very disturbing is the organic substance. The existence of high organic matter within the river water is often expressed in permanganate number that has passed the quality standard. River that contain high organic matter usually the water smell and the color is black, besides it can also cause disturbances in the water treatment process, which is an increasing use of coagulants, chlorine, activated carbon, and the emergence of substances that are not desired, and the quality of treatment results are unsatisfactory. Many ways to reduce the organic matter in river water, one of them is by using the biofilter honeycomb structure. The target of the reduction of organic substances is that the river water could be used as a raw drinking water quality standards or meet the category B, Regulation of Jakarta Governor Number 582, 1995. Raw water used for this study were taken from Krukut River which is the raw water for Regional Water Company PALYJA, Production Installation III Cilandak, South Jakarta and Cengkareng Drain river water, which is currently used as a source of raw water for PAM Taman Kota, West Jakarta using a biofilter reactor aerobic system, the capacity of 50 - 200 m3, Capasity of Blowers 300 l /min, Residence Time 6 hours up to 1 hour. Test results on the residence time of 1 hour, parameters pH, TSS, turbidity, organic substances, detergents, manganese, ammonia, nitrite, nitrate, can meet the standard, except for iron which still exceeds the standard. To improve the removal  efficiency of organic matter and iron, at the beginning of processing before entering into the drinking water treatment unit need to be added powder active carbon and an oxidizing agent with a sufficient dose. Keywords: Organic substances, biofilter, aerobic, honeycomb plastic media.


Sign in / Sign up

Export Citation Format

Share Document