scholarly journals Recent Advances in Portable Biosensors for Biomarker Detection in Body Fluids

Biosensors ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 127 ◽  
Author(s):  
Brian Senf ◽  
Woon-Hong Yeo ◽  
Jong-Hoon Kim

A recent development in portable biosensors allows rapid, accurate, and on-site detection of biomarkers, which helps to prevent disease spread by the control of sources. Less invasive sample collection is necessary to use portable biosensors in remote environments for accurate on-site diagnostics and testing. For non- or minimally invasive sampling, easily accessible body fluids, such as saliva, sweat, blood, or urine, have been utilized. It is also imperative to find accurate biomarkers to provide better clinical intervention and treatment at the onset of disease. At the same time, these reliable biomarkers can be utilized to monitor the progress of the disease. In this review, we summarize the most recent development of portable biosensors to detect various biomarkers accurately. In addition, we discuss ongoing issues and limitations of the existing systems and methods. Lastly, we present the key requirements of portable biosensors and discuss ideas for functional enhancements.

Chemosensors ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 85
Author(s):  
Anton Popov ◽  
Benediktas Brasiunas ◽  
Asta Kausaite-Minkstimiene ◽  
Almira Ramanaviciene

With the increasing importance of healthcare and clinical diagnosis, as well as the growing demand for highly sensitive analytical instruments, immunosensors have received considerable attention. In this review, electrochemical immunosensor signal amplification strategies using metal nanoparticles (MNPs) and quantum dots (Qdots) as tags are overviewed, focusing on recent developments in the ultrasensitive detection of biomarkers. MNPs and Qdots can be used separately or in combination with other nanostructures, while performing the function of nanocarriers, electroactive labels, or catalysts. Thus, different functions of MNPs and Qdots as well as recent advances in electrochemical signal amplification are discussed. Additionally, the methods most often used for antibody immobilization on nanoparticles, immunoassay formats, and electrochemical methods for indirect biomarker detection are overviewed.


2020 ◽  
Vol 12 (1) ◽  
pp. 7-19
Author(s):  
Guerrero Gutiérrez Manuel Alberto ◽  
Pérez Nieto Orlando Rubén ◽  
Eder Iván Zamarrón López ◽  
Jesús Salvador Sánchez Díaz ◽  
Escarramán Martínez Diego ◽  
...  

The hemodynamic monitoring is a fundamental part of the patient in the perioperative period, during the last decade the monitoring at the patient's bedside has grown at giant steps, from the emergency area, operating room, to the Intensive Care area. One of its most important advances is the decrease in the use of pulmonary artery catheter, which is being replaced by ultrasound and less invasive monitoring techniques, in this article we will review from the beginning of the monitoring to the most used less invasive monitors currently.


2019 ◽  
Vol 23 (46) ◽  
pp. 1-104 ◽  
Author(s):  
Celine Lewis ◽  
John C Hutchinson ◽  
Megan Riddington ◽  
Melissa Hill ◽  
Owen J Arthurs ◽  
...  

BackgroundLess invasive perinatal and paediatric autopsy methods, such as imaging alongside targeted endoscopy and organ biopsy, may address declining consent rates for traditional autopsy, but their acceptability and accuracy are not known.ObjectivesThe aims of this study were to provide empirical data on the acceptability and likely uptake for different types of autopsy among key stakeholders (study 1); and to analyse existing autopsy data sources to provide estimates of the potential efficacy of less invasive autopsy (LIA) and its projected utility in clinical practice (study 2).Review methodsStudy 1: this was a mixed-methods study. Parents were involved in research design and interpretation of findings. Substudy 1: a cross-sectional survey of 859 parents who had experienced miscarriage, termination of pregnancy for fetal anomaly, stillbirth, infant or child death, and interviews with 20 responders. Substudy 2: interviews with 25 health professionals and four coroners. Substudy 3: interviews with 16 religious leaders and eight focus groups, with 76 members of the Muslim and Jewish community. Study 2: a retrospective analysis of national data in addition to detailed information from an existing in-house autopsy database of > 5000 clinical cases that had undergone standard autopsy to determine the proportion of cases by clinical indication group for which tissue sampling of specific internal organs significantly contributed to the diagnosis.ResultsSubstudy 1: 91% of participants indicated that they would consent to some form of LIA, 54% would consent to standard autopsy, 74% to minimally invasive autopsy (MIA) and 77% to non-invasive autopsy (NIA). Substudy 2: participants viewed LIA as a positive development, but had concerns around the limitations of the technology and de-skilling the workforce. Cost implications, skills and training requirements were identified as implementation challenges. Substudy 3: religious leaders agreed that NIA was religiously permissible, but MIA was considered less acceptable. Community members indicated that they might consent to NIA if the body could be returned for burial within 24 hours. Study 2: in 5–10% of cases of sudden unexplained death in childhood and sudden unexplained death in infants, the final cause of death is determined by routine histological sampling of macroscopically normal organs, predominantly the heart and lungs, and in this group routine histological sampling therefore remains an important aspect of investigation. In contrast, routine histological examination of macroscopically normal organs rarely (< 0.5%) provides the cause of death in fetal cases, making LIA and NIA approaches potentially highly applicable.LimitationsA key limitation of the empirical research is that it is hypothetical. Further research is required to determine actual uptake. Furthermore, because of the retrospective nature of the autopsy data set, findings regarding the likely contribution of organ sampling to final diagnosis are based on extrapolation of findings from historical autopsies, and prospective data collection is required to validate the conclusions.ConclusionsLIA is viable and acceptable (except for unexplained deaths), and likely to increase uptake. Further health economic, performance and implementation studies are required to determine the optimal service configuration required to offer this as routine clinical care.FundingThe National Institute for Health Research Health Technology Assessment programme.


Micromachines ◽  
2019 ◽  
Vol 10 (8) ◽  
pp. 516 ◽  
Author(s):  
Veasna Soum ◽  
Sooyong Park ◽  
Albertus Ivan Brilian ◽  
Oh-Sun Kwon ◽  
Kwanwoo Shin

Recent advanced paper-based microfluidic devices provide an alternative technology for the detection of biomarkers by using affordable and portable devices for point-of-care testing (POCT). Programmable paper-based microfluidic devices enable a wide range of biomarker detection with high sensitivity and automation for single- and multi-step assays because they provide better control for manipulating fluid samples. In this review, we examine the advances in programmable microfluidics, i.e., paper-based continuous-flow microfluidic (p-CMF) devices and paper-based digital microfluidic (p-DMF) devices, for biomarker detection. First, we discuss the methods used to fabricate these two types of paper-based microfluidic devices and the strategies for programming fluid delivery and for droplet manipulation. Next, we discuss the use of these programmable paper-based devices for the single- and multi-step detection of biomarkers. Finally, we present the current limitations of paper-based microfluidics for biomarker detection and the outlook for their development.


1998 ◽  
Vol 64 (8) ◽  
pp. 3066-3069 ◽  
Author(s):  
Sergio Marshall ◽  
Sekou Heath ◽  
Vitalia Henríquez ◽  
Cristián Orrego

ABSTRACT The attributes of the PCR allowed implementation of an assay for specific detection of Piscirickettsia salmonis from a few microliters of fish serum. This opens the way to less invasive modes of sampling for this microbial pathogen in salmonids.


2018 ◽  
Vol 3 (2) ◽  
pp. 138-145 ◽  
Author(s):  
Taro Oshikiri ◽  
Gosuke Takiguchi ◽  
Susumu Miura ◽  
Nobuhisa Takase ◽  
Hiroshi Hasegawa ◽  
...  

2010 ◽  
Vol 25 (6) ◽  
pp. 970-976 ◽  
Author(s):  
Shigeyoshi Tsuji ◽  
Tetsuya Tomita ◽  
Masakazu Fujii ◽  
Richard S. Laskin ◽  
Hideki Yoshikawa ◽  
...  

2002 ◽  
Vol 25 (4) ◽  
pp. 318-323 ◽  
Author(s):  
M.W. Wichmann ◽  
G. Meyer ◽  
M.K. Angele ◽  
F.-W. Schildberg ◽  
H.G. Rau

2002 ◽  
Vol 33 (1) ◽  
pp. 4-8 ◽  
Author(s):  
Jessica A. Barlow

Each of the articles in this forum considers how phonology interacts with other aspects of language and language learning. The contributors show that this interaction plays a major role in a child’s learning of language, whether through typical routes, as evidenced by the normally developing child, or through clinical intervention. These interactions are apparent in both typical and atypical language learning, with the development of the lexicon being closely tied to the development of phonological representations (or URs). The correctness of these URs, as determined from morphophonemic alternations, plays a major role in accounting for children’s production patterns and determining what a child "knows" about the target sound system. Finally, the interaction between morphosyntax and phonology can be observed in language learning even when it occurs as a result of clinical intervention. It is hoped that this clinical forum will be informative and enlightening for researchers and clinical professionals.


Sign in / Sign up

Export Citation Format

Share Document