scholarly journals Computational Simulation of Wind Microclimate in Complex Urban Models and Mitigation Using Trees

Buildings ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 112
Author(s):  
Azin Hosseinzadeh ◽  
Amir Keshmiri

Due to a rapid increase in urbanisation, accurate wind microclimate assessment is of crucial importance. Evaluating wind flows around buildings is part of the planning application process in the design of new developments. In this study, computational fluid dynamics (CFD) simulations are carried out for a case study, representing the East Village in the London Olympic Park. Following a validation test against experimental data for a simpler urban configuration, the key input parameters, including appropriate boundary conditions, mesh setting and type of turbulence model, are selected for the Olympic Park model. All the simulations are conducted using the commercial code STARCCM+ under steady-state conditions with the Reynolds-averaged Navier–Stokes (RANS) method. The turbulence is modelled using different common variants of eddy-viscosity models (EVMs) including standard k-ε, realizable k-ε and standard and shear stress transport (SST) k-ω. The results demonstrate that standard and realisable k-ε models correlate very well with the experimental data, while some discrepancies are found with standard and SST k-ω. Following the determination of areas of high velocity, appropriate tree planting is proposed to overcome the effect of corner and downwash acceleration. With the optimised arrangement of trees and using specific types of tree (e.g., birch), wind speeds at the pedestrian level are reduced by 3.5, 25 and 66% in three main regions of interest. Moreover, we investigate the effects of tree heights. The obtained results illustrate that the wind velocity reduces when the crowns of the trees are located closer to the buildings and the ground. Our high-resolution CFD simulation and results offer a quantitative tool for wind microclimate assessment and optimised design and arrangement of trees around buildings to improve pedestrian comfort.

2014 ◽  
Vol 679 ◽  
pp. 35-38 ◽  
Author(s):  
Azim Arshad ◽  
Shahrani Anuar ◽  
Ahmmad Shukrie ◽  
Rosdi Hussin

CFD simulation of a tidal current turbine shroud was performed using Ansys FLUENT commercial code and comparison was made with experimental data. The simulation result obtained was in good agreement with the experimental data. The coefficient of velocity, Cv was in the range of approximately 1.2 to 1.4 for both simulation and experiment. The present study gave useful information on the viability of CFD simulation for the initial evaluation of shroud design performance.


2021 ◽  
Vol 29 (2) ◽  
pp. 55-61
Author(s):  
Olga Hubová ◽  
Marek Macák ◽  
Alžbeta Grmanová

Abstract Our calculation of wind effects was based on the specific wind situation of the planned R2 expressway. Given the topography and the prevailing wind directions, it was necessary to analyse the speeds for winds that could cause vehicles with trailers to be pushed off the roadway, as has been observed in recent years. Using a CFD simulation in the ANSYS FLUENT program, we analysed the entire section of the planned R2 expressway in order to evaluate the wind speeds at the level of the centre of gravity of truck trailers. Statistical turbulence models based on a time-averaging method, i.e., the RANS-Reynolds Averaged Navier-Stokes equations, of turbulent flow quantities and the time-averaging procedure of balance equations are suitable for solving the engineering tasks. In numerical simulations, the Realizable k - ε model was used in which the calculation of the turbulent dynamic viscosity in the equation for Boussinesque’s hypothesis was solved using two transport equations. Plotting and comparing the wind speeds for significant wind directions allowed us to design protection in the dangerous areas using protective walls.


Processes ◽  
2021 ◽  
Vol 9 (7) ◽  
pp. 1192
Author(s):  
Dong-Hyun Kim ◽  
Jong-Chun Park ◽  
Gyu-Mok Jeon ◽  
Myung-Soo Shin

In this paper, the efficiency of Propeller Boss Cap Fins (PBCF) installed at the bulk carrier was estimated under both Propeller Open Water (POW) and self-propulsion conditions. For this estimation, virtual model-basin tests (resistance, POW, and self-propulsion tests) were conducted through Computational Fluid Dynamics (CFDs) simulation. In the resistance test, the total resistance and the wake distribution according to ship speed were investigated. In the POW test, changes of thrust, torque coefficient, and open water efficiency on the propeller according to PBCF installation were investigated. Finally, the International Towing Tank Conference (ITTC) 1978 method was used to predict the effect of PBCF installation on self-propulsive coefficient and brake horsepower. For analyzing incompressible viscous flow field, the Reynolds-Averaged Navier–Stokes (RANS) equation with SST k-ω turbulence model was calculated using Star-CCM+ 11.06.010-R8. All simulation results were validated by comparing the results of model tests conducted at the Korea Research Institute of Ships and Ocean Engineering (KRISO). Consequently, for the self-propulsion test with the PBCF, a 1.5% reduction of brake horsepower was estimated in the simulation and a 0.5% reduction of the brake horsepower was estimated in the experiment.


2011 ◽  
Vol 133 (5) ◽  
Author(s):  
F. P. P. Tan ◽  
N. B. Wood ◽  
G. Tabor ◽  
X. Y. Xu

In this study, two different turbulence methodologies are investigated to predict transitional flow in a 75% stenosed axisymmetric experimental arterial model and in a slightly modified version of the model with an eccentric stenosis. Large eddy simulation (LES) and Reynolds-averaged Navier–Stokes (RANS) methods were applied; in the LES simulations eddy viscosity subgrid-scale models were employed (basic and dynamic Smagorinsky) while the RANS method involved the correlation-based transitional version of the hybrid k-ε/k-ω flow model. The RANS simulations used 410,000 and 820,000 element meshes for the axisymmetric and eccentric stenoses, respectively, with y+ less than 2 viscous wall units for the boundary elements, while the LES used 1,200,000 elements with y+ less than 1. Implicit filtering was used for LES, giving an overlap between the resolved and modeled eddies, ensuring accurate treatment of near wall turbulence structures. Flow analysis was carried out in terms of vorticity and eddy viscosity magnitudes, velocity, and turbulence intensity profiles and the results were compared both with established experimental data and with available direct numerical simulations (DNSs) from the literature. The simulation results demonstrated that the dynamic Smagorinsky LES and RANS transitional model predicted fairly comparable velocity and turbulence intensity profiles with the experimental data, although the dynamic Smagorinsky model gave the best overall agreement. The present study demonstrated the power of LES methods, although they were computationally more costly, and added further evidence of the promise of the RANS transition model used here, previously tested in pulsatile flow on a similar model. Both dynamic Smagorinsky LES and the RANS model captured the complex transition phenomena under physiological Reynolds numbers in steady flow, including separation and reattachment. In this respect, LES with dynamic Smagorinsky appeared more successful than DNS in replicating the axisymmetric experimental results, although inflow conditions, which are subject to caveats, may have differed. For the eccentric stenosis, LES with Smagorinsky coefficient of 0.13 gave the closest agreement with DNS despite the known shortcomings of fixed coefficients. The relaminarization as the flow escaped the influence of the stenosis was amply demonstrated in the simulations, graphically so in the case of LES.


Author(s):  
B. Elie ◽  
G. Reliquet ◽  
P.-E. Guillerm ◽  
O. Thilleul ◽  
P. Ferrant ◽  
...  

This paper compares numerical and experimental results in the study of the resonance phenomenon which appears between two side-by-side fixed barges for different sea-states. Simulations were performed using SWENSE (Spectral Wave Explicit Navier-Stokes Equations) approach and results are compared with experimental data on two fixed barges with different headings and bilges. Numerical results, obtained using the SWENSE approach, are able to predict both the frequency and the magnitude of the RAO functions.


Author(s):  
K. J. Standish ◽  
C. P. van Dam

The adoption of blunt trailing edge airfoils for the inner regions of large wind turbine blades has been proposed. Blunt trailing edge airfoils would not only provide increased structural volume, but have also been found to improve the lift characteristics of airfoils and therefore allow for section shapes with a greater maximum thickness. Limited experimental data makes it difficult for wind turbine designers to consider and conduct tradeoff studies using these section shapes. This lack of experimental data precipitated the present analysis of blunt trailing edge airfoils using computational fluid dynamics. Several computational techniques are applied including a viscous/inviscid interaction method and several Reynolds-averaged Navier-Stokes methods.


Author(s):  
Yogini Patel ◽  
Giteshkumar Patel ◽  
Teemu Turunen-Saaresti

The aim of the paper is to analyse the effect of turbulence and real gas models on the process of spontaneous condensation in converging diverging (CD) nozzle by using commercial Computational Fluid Dynamics (CFD) code. The calculations were based on the 2-D compressible Navier-Stokes (NS) equations coupled with two-equation turbulence model, and the non-equilibrium spontaneous condensing steam flow was solved on the basis of the classical nucleation theory. The results were validated to the available experimental data.


2014 ◽  
Vol 554 ◽  
pp. 696-700 ◽  
Author(s):  
Nur Farhana Mohamad Kasim ◽  
Sheikh Ahmad Zaki ◽  
Mohamed Sukri Mat Ali ◽  
Ahmad Faiz Mohammad ◽  
Azli Abd Razak

Wind-induced ventilation is widely acknowledged as one of the best approaches for inducing natural ventilation. Computational fluid dynamics (CFD) technique is gaining popularity among researchers as an alternative for experimental methods to investigate the behavior of wind-driven ventilation in building. In this present paper, Reynolds averaged Navier-Stokes equation (RANS) k-ε model approach is considered to simulate the airflow on a simplified cubic building with an opening on a single façade. Preliminary simulation using models from previous experiment indicates the reliability of OpenFOAM, the open source software that will be used in this study. The results obtained in this study will better define options for our future study which aims to explore how different buildings arrays modify the airflow inside and around a naturally ventilated building.


2021 ◽  
Author(s):  
Matthew Searle ◽  
Arnab Roy ◽  
James Black ◽  
Doug Straub ◽  
Sridharan Ramesh

Abstract In this paper, experimental and numerical investigations of three variants of internal cooling configurations — dimples only, ribs only and ribs with dimples have been explored at process conditions (96°C and 207bar) with sCO2 as the coolant. The designs were chosen based on a review of advanced internal cooling features typically used for air-breathing gas turbines. The experimental study described in this paper utilizes additively manufactured square channels with the cooling features over a range of Reynolds number from 80,000 to 250,000. Nusselt number is calculated in the experiments utilizing the Wilson Plot method and three heat transfer characteristics — augmentation in Nusselt number, friction factor and overall Thermal Performance Factor (TPF) are reported. To explore the effect of surface roughness introduced due to additive manufacturing, two baseline channel flow cases are considered — a conventional smooth tube and an additively manufactured square tube. A companion computational fluid dynamics (CFD) simulation is also performed for the corresponding cooling configurations reported in the experiments using the Reynolds Averaged Navier Stokes (RANS) based turbulence model. Both experimental and computational results show increasing Nusselt number augmentation as higher Reynolds numbers are approached, whereas prior work on internal cooling of air-breathing gas turbines predict a decay in the heat transfer enhancement as Reynolds number increases. Comparing cooling features, it is observed that the “ribs only” and “ribs with dimples” configurations exhibit higher Nusselt number augmentation at all Reynolds numbers compared to the “dimples only” and the “no features” configurations. However, the frictional losses are almost an order of magnitude higher in presence of ribs.


Author(s):  
Pingfan He ◽  
Dragos Licu ◽  
Martha Salcudean ◽  
Ian S. Gartshore

The effect of varying coolant density on film cooling effectiveness for a turbine blade-model was numerically investigated and compared with experimental data. This model had a semi-circular leading edge with four rows of laterally-inclined film cooling orifices positioned symmetrically about the stagnation line. A curvilinear coordinate-based CFD code was developed and used for the numerical investigation. The code used a domain segmentation strategy in conjunction with general curvilinear grids to model the complex blade configuration. A multigrid method was used to accelerate the convergence rate. The time-averaged, variable-density, Navier-Stokes equations together with the energy or scalar equation were solved. Turbulence closure was attained by the standard k–ε model with a near-wall k model. Either air or CO2 was used as coolant in three cases of injection through single rows and alternatively staggered double raws of holes. Two different blowing rates were investigated in each case and compared with experimental data. The experimental results were obtained using a wind tunnel model, and the mass/heat analogy was used to determine the film cooling effectiveness. The higher density of the carbon dioxide coolant (approximately 1.5 times the density of air) in the isothermal mass injection experiments, was used to simulate the effects of injection of a colder air in the corresponding adiabatic heat transfer situation. Good agreement between calculated and measured film cooling effectiveness was found for low blowing ratio M ≤ 0.5 and the effect of density was not significant. At higher blowing ratio M > 1 the calculations consistently overpredict the measured values of film cooling effectiveness.


Sign in / Sign up

Export Citation Format

Share Document