scholarly journals Improving the IAQ for Learning Efficiency with Indoor Plants in University Classrooms in Ajman, United Arab Emirates

Buildings ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 289
Author(s):  
Chuloh Jung ◽  
Jihad Awad

The objective of this paper is to investigate the effect of improving indoor air quality with indoor plants. As a methodology, two target classrooms with the same size (120.64 m2) and 32 students per room were selected. Then, 48 areca palm pots (average leaf area of 300 cm2/pot) were placed, and the plant density was 14.68% of the floor area. Subjective assessment for general questions, learning motivation, perceived air quality, and SBS symptoms was conducted at 5 min after the class started and 5 min before the class ended. The results showed that the CO2 concentration by respiration of the students (average of 1873 ppm) exceeded the regulatory standard (1000 ppm), but the students did not recognize the indoor CO2 concentration. The increase in CO2 concentration in the classroom was lower in the case with plant placement (624 ppm) compared with the case without plant placement (about 1205 ppm). It was statistically proven that the CO2 concentration by respiration could be reduced by 50% if the indoor plant leaf area density were maintained at about 14.68% of the floor area. In the case with plant placement, the students perceived the indoor air quality to be 40% fresher and showed a 140% higher acceptability. Moreover, the complaining of SBS symptoms was improved by 108%, and the students’ perception that it was better to focus on learning increased by about 120%. As the awareness of sustainability increases, indoor plants will be more actively placed in the United Arab Emirates. Indoor plants not only provide a visual green effect to improve human comfort but also purify indoor air pollutants.

2021 ◽  
Vol 13 (8) ◽  
pp. 4139
Author(s):  
Muriel Diaz ◽  
Mario Cools ◽  
Maureen Trebilcock ◽  
Beatriz Piderit-Moreno ◽  
Shady Attia

Between the ages of 6 and 18, children spend between 30 and 42 h a week at school, mostly indoors, where indoor environmental quality is usually deficient and does not favor learning. The difficulty of delivering indoor air quality (IAQ) in learning facilities is related to high occupancy rates and low interaction levels with windows. In non-industrialized countries, as in the cases presented, most classrooms have no mechanical ventilation, due to energy poverty and lack of normative requirements. This fact heavily impacts the indoor air quality and students’ learning outcomes. The aim of the paper is to identify the factors that determine acceptable CO2 concentrations. Therefore, it studies air quality in free-running and naturally ventilated primary schools in Chile, aiming to identify the impact of contextual, occupant, and building design factors, using CO2 concentration as a proxy for IAQ. The monitoring of CO2, temperature, and humidity revealed that indoor air CO2 concentration is above 1400 ppm most of the time, with peaks of 5000 ppm during the day, especially in winter. The statistical analysis indicates that CO2 is dependent on climate, seasonality, and indoor temperature, while it is independent of outside temperature in heated classrooms. The odds of having acceptable concentrations of CO2 are bigger when indoor temperatures are high, and there is a need to ventilate for cooling.


Buildings ◽  
2020 ◽  
Vol 10 (7) ◽  
pp. 124 ◽  
Author(s):  
Claire Tam ◽  
Yuqing Zhao ◽  
Zaiyi Liao ◽  
Lian Zhao

Indoor air quality and thermal conditions are important considerations when designing indoor spaces to ensure occupant health, satisfaction, and productivity. Carbon dioxide (CO2) concentration and indoor air temperature are two measurable parameters to assess air quality and thermal conditions within a space. Occupants are progressively affected by the indoor environment as the time spent indoors prolongs. Specifically, there is an interest in carrying out investigations on the indoor environment through surveying existing Heating, Ventilation, Air Conditioning (HVAC) system operations in classrooms. Indoor air temperature and CO2 concentration in multiple lecture halls in Toronto, Canada were monitored; observations consistently show high indoor air temperature (overheating) and high CO2 concentration. One classroom is chosen as a representative case study for this paper. The results verify a strong correlation between the number of occupants and the increase in air temperature and CO2 concentration. Building Energy Simulation (BES) is used to investigate the causes of discomfort in the classroom, and to identify methods for regulating the temperature and CO2 concentration. This paper proposes retro-commissioning strategies that could be implemented in institutional buildings; specifically, the increase of outdoor airflow rate and the addition of occupancy-based pre-active HVAC system control. The proposed retrofit cases reduce the measured overheating in the classrooms by 2-3 °C (indoor temperature should be below 23 °C) and maintain CO2 concentration under 900 ppm (the CO2 threshold is 1000 ppm), showing promising improvements to a classroom’s thermal condition and indoor air quality.


2014 ◽  
Vol 40 (3) ◽  
pp. 259-268 ◽  
Author(s):  
Ana Maria da Conceição Ferreira ◽  
Massano Cardoso

Objective: To determine whether indoor air quality in schools is associated with the prevalence of allergic and respiratory diseases in children. Methods: We evaluated 1,019 students at 51 elementary schools in the city of Coimbra, Portugal. We applied a questionnaire that included questions regarding the demographic, social, and behavioral characteristics of students, as well as the presence of smoking in the family. We also evaluated the indoor air quality in the schools. Results: In the indoor air of the schools evaluated, we identified mean concentrations of carbon dioxide (CO2) above the maximum reference value, especially during the fall and winter. The CO2 concentration was sometimes as high as 1,942 ppm, implying a considerable health risk for the children. The most prevalent symptoms and respiratory diseases identified in the children were sneezing, rales, wheezing, rhinitis, and asthma. Other signs and symptoms, such as poor concentration, cough, headache, and irritation of mucous membranes, were identified. Lack of concentration was associated with CO2 concentrations above the maximum recommended level in indoor air (p = 0.002). There were no other significant associations. Conclusions: Most of the schools evaluated presented with reasonable air quality and thermal comfort. However, the concentrations of various pollutants, especially CO2, suggest the need for corrective interventions, such as reducing air pollutant sources and improving ventilation. There was a statistically significant association between lack of concentration in the children and exposure to high levels of CO2. The overall low level of pollution in the city of Coimbra might explain the lack of other significant associations.


Proceedings ◽  
2018 ◽  
Vol 2 (20) ◽  
pp. 1309 ◽  
Author(s):  
Antonio Rodero ◽  
Dorota Anna Krawczyk

Carbon dioxide concentration is an important parameter to know Indoor Air Quality of a building. One of the most important sources of CO2 in poor ventilated building is human activity. This work presents a method for experimental determination of human CO2 generation rate based on measuring of time evolution of indoor CO2 concentration. The method is applied to 5 rooms of an educational building from Bialystok (Poland). Similar carbon dioxide gains were obtained in all rooms, around 0.0046 L/s, which correspond to theoretical CO2 generation rates of a sedentary activity for persons, males and females, between 21–30 years old, characteristics of occupants of analyzed rooms.


Author(s):  
Cesira Pasquarella ◽  
Carla Balocco ◽  
Maria Eugenia Colucci ◽  
Elisa Saccani ◽  
Samuel Paroni ◽  
...  

Surgical staff behavior in operating theatres is one of the factors associated with indoor air quality and surgical site infection risk. The aim of this study was to apply an approach including microbiological, particle, and microclimate parameters during two simulated surgical hip arthroplasties to evaluate the influence of staff behavior on indoor air quality. During the first hip arthroplasty, the surgical team behaved correctly, but in the second operation, behavioral recommendations were not respected. Microbiological contamination was evaluated by active and passive methods. The air velocity, humidity, temperature, and CO2 concentration were also monitored. The highest levels of microbial and particle contamination, as well as the highest variation in the microclimate parameter, were recorded during the surgical operation where the surgical team behaved “incorrectly”. Turbulent air flow ventilation systems appeared more efficient than in the past and very low air microbial contamination was reached when behavior was correct. Therefore, adherence to behavioral recommendations in operating theatres is essential to not undermine the effectiveness of the heating, ventilation, and air conditioning systems and employed resources.


Atmosphere ◽  
2020 ◽  
Vol 11 (3) ◽  
pp. 271 ◽  
Author(s):  
Kanittha Pamonpol ◽  
Thanita Areerob ◽  
Kritana Prueksakorn

Optimum thermal comfort and good indoor air quality (IAQ) is important for occupants. In tropical region offices, an air conditioner is indispensable due to extreme high temperatures. However, the poor ventilation causes health issues. Therefore, the purpose of this study was to propose an improving IAQ method with low energy consumption. Temperature, relative humidity, and CO2 and CO concentration were monitored in a poorly ventilated office for one year to observe seasonal variation. The results showed that the maximum CO2 concentration was above the recommended level for comfort. Simple ventilated practices and placing a number of Sansevieria trifasciata (S. trifasciata) plants were applied to improve the IAQ with the focus on decreasing CO2 concentration as well as achieving energy saving. Reductions of 19.9%, 22.5%, and 58.2% of the CO2 concentration were achieved by ventilation through the door during lunchtime, morning, and full working period, respectively. Placing S. trifasciata in the office could reduce the CO2 concentration by 10.47%–19.29%. A computer simulation was created to observe the efficiency of simple practices to find the optimum conditions. An electricity cost saving of 24.3% was projected for the most feasible option with a consequent reduction in global warming potential, which also resulted in improved IAQ.


Buildings ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 353
Author(s):  
Jihad Awad ◽  
Chuloh Jung

The Public Health and Safety Department of Dubai Municipality had evaluated the indoor air quality in public buildings in 2013, then established the IAQ (Indoor Air Quality) regulation. Even though IAQ in public building is in control, indoor air pollution in new and renovated housing is still very problematic. The objective of this paper is to measure the indoor air quality of the residential unit in an apartment after renovation to evaluate the actual condition and to analyze the influential factors. As a methodology, field measurements, resident interviews, and observations were conducted for 20 residential units to investigate basic information, renovation contents, ventilation characteristics, and SBS (Sick Building Syndrome) symptoms. The results showed that renovation related to the indoor air quality was the replacement of finishing materials. It was statistically proven that the average CO2 for each house was 683–2309.4 ppm, and 15 houses exceeded the WHO IAQ standards. TVOC had an average concentration of 0–3.0 ppm per house, exceeding the standard in 10 houses. Formaldehyde (CH2O) had an average concentration of 0–1.02 ppm per house, exceeding the WHO IAQ standard (0.1 ppm) in 12 houses. However, even though the indoor air quality was polluted, the residents were hardly aware of it based on subjective response survey. As the amount of renovation increases, the concentration of formaldehyde (CH2O) increases significantly, and excessive renovation should be avoided. This study will serve as a basic dataset to suggest that the new IAQ regulation not be compulsory for residents; rather, they must induce contractors with stipulation to maintain IAQ during and after renovation.