scholarly journals Tensile Behavior of Self-Compacting Steel Fiber Reinforced Concrete Evaluated by Different Test Methods

Crystals ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 251
Author(s):  
Xinxin Ding ◽  
Changyong Li ◽  
Minglei Zhao ◽  
Jie Li ◽  
Haibin Geng ◽  
...  

Due to the mechanical properties related closely to the distribution of steel fibers in concrete matrix, the assessment of tensile strength of self-compacting steel fiber reinforced concrete (SFRC) is significant for the engineering application. In this paper, seven groups of self-compacting SFRC were produced with the mix proportion designed by using the steel fiber-aggregates skeleton packing test method. The hooked-end steel fibers with length of 25.1 mm, 29.8 mm and 34.8 mm were used, and the volume fraction varied from 0.4% to 1.4%. The axial tensile test of notched sectional prism specimen and the splitting tensile test of cube specimen were carried out. Results show that the axial tensile strength was higher than the splitting tensile strength for the same self-compacting SFRC, the axial tensile work and toughness was not related to the length of steel fiber. Finally, the equations for the prediction of tensile strength of self-compacting SFRC are proposed considering the fiber distribution and fiber factor, and the adaptability of splitting tensile test for self-compacting SFRC is discussed.

2021 ◽  
pp. 136943322098165
Author(s):  
Hossein Saberi ◽  
Farzad Hatami ◽  
Alireza Rahai

In this study, the co-effects of steel fibers and FRP confinement on the concrete behavior under the axial compression load are investigated. Thus, the experimental tests were conducted on 18 steel fiber-reinforced concrete (SFRC) specimens confined by FRP. Moreover, 24 existing experimental test results of FRP-confined specimens tested under axial compression are gathered to compile a reliable database for developing a mathematical model. In the conducted experimental tests, the concrete strength was varied as 26 MPa and 32.5 MPa and the steel fiber content was varied as 0.0%, 1.5%, and 3%. The specimens were confined with one and two layers of glass fiber reinforced polymer (GFRP) sheet. The experimental test results show that simultaneously using the steel fibers and FRP confinement in concrete not only significantly increases the peak strength and ultimate strain of concrete but also solves the issue of sudden failure in the FRP-confined concrete. The simulations confirm that the results of the proposed model are in good agreement with those of experimental tests.


Author(s):  
Natalia Sharma

Abstract: Reinforced concrete structures are frequently in need of repair and strengthening as a result of numerous environmental causes, ageing, or material damage under intense stress conditions, as well as mistakes made during the construction process. RC structures are repaired using a variety of approaches nowadays. The usage of FRC is one of the retrofitting strategies. Steel fiber reinforced concrete (SFRC) was used in this investigation because it contains randomly dispersed short discrete steel fibers that operate as internal reinforcement to improve the cementitious composite's characteristics (concrete). The main rationale for integrating small discrete fibers into a cement matrix is to reduce the amount of cement used. The principal reason for incorporating short discrete fibers into a cement matrix is to reduce cracking in the elastic range, increase the tensile strength and deformation capacity and increase the toughness of the resultant composite. These properties of SFRC primarily depend upon length and volume of Steel fibers used in the concrete mixture. In India, the steel fiber reinforced concrete (SFRC) has seen limited applications in several structures due to the lack of awareness, design guidelines and construction specifications. Therefore, there is a need to develop information on the role of steel fibers in the concrete mixture. The experimental work reported in this study includes the mechanical properties of concrete at different volume fractions of steel fibers. These mechanical properties include compressive strength, split tensile strength and flexural strength and to study the effect of volume fraction and aspect ratio of steel fibers on these mechanical properties. However, main aim of the study was significance of reinforced concrete beams strengthened with fiber reinforced concrete layer and to investigate how these beams deflect under strain. The objective of the investigation was finding that applying FRC to strengthen beams enhanced structural performance in terms of ultimate load carrying capacity, fracture pattern deflection, and mode of failure or not.


2010 ◽  
Vol 168-170 ◽  
pp. 1762-1766
Author(s):  
Min Sun ◽  
Di Jiang Wen ◽  
Peng Xie

The interface bond between steel fibers and concrete matrix is the key of carrying capacity of steel fiber reinforced concrete(SFRC). In marine tidal fluctuation zone and splashed area, steel fibers will be rusty, and the bending toughness of SFRC was weakened. In this study, we tried to improve corrosion resistance of steel fiber and the interface bond strength by depositing zinc phosphate coating on steel fiber. These zinc phosphate steel fiber reinforced concrete(ZSFRC) have higher anti-corrosion ability. After corrosion they still have higher bending toughness than common SFRC.


2012 ◽  
Vol 204-208 ◽  
pp. 3740-3743
Author(s):  
Wen Cui ◽  
Qin Luo

Mix design of the steel fiber reinforced concrete was analyzed based on the engineering conditions. It was indicated by comparing with the strength values of steel fiber reinforced concrete (CF40) and ordinary concrete (C40) that the tensile strength of the steel fiber reinforced concrete increased about 70%, the compressive strength increased about 10%, the initial cracking strength increased about 150%.The reasonable construction technologies were used in mixing, transportation, pouring, vibrating and curing of the steel fiber reinforced concrete in order to ensure quality of the construction.


2012 ◽  
Vol 5 (1) ◽  
pp. 1-11 ◽  
Author(s):  
A. D. de Figueiredo ◽  
A. de la Fuente ◽  
A. Aguado ◽  
C. Molins ◽  
P. J. Chama Neto

This paper is the first part of an extensive work focusing the technological development of steel fiber reinforced concrete pipes (FRCP). Here is presented and discussed the experimental campaign focusing the test procedure and the mechanical behavior obtained for each of the dosages of fiber used. In the second part ("Steel fiber reinforced concrete pipes. Part 2: Numerical model to simulate the crushing test"), the aspects of FRCP numerical modeling are presented and analyzed using the same experimental results in order to be validated. This study was carried out trying to reduce some uncertainties related to FRCP performance and provide a better condition to the use of these components. In this respect, an experimental study was carried out using sewage concrete pipes in full scale as specimens. The diameter of the specimens was 600 mm, and they had a length of 2500 mm. The pipes were reinforced with traditional bars and different contents of steel fibers in order to compare their performance through the crushing test. Two test procedures were used in that sense. In the 1st Series, the diameter displacement was monitored by the use of two LVDTs positioned at both extremities of the pipes. In the 2nd Series, just one LVDT is positioned at the spigot. The results shown a more rigidity response of the pipe during tests when the displacements were measured at the enlarged section of the socket. The fiber reinforcement was very effective, especially when low level of displacement was imposed to the FRCP. At this condition, the steel fibers showed an equivalent performance to superior class pipes made with traditional reinforced. The fiber content of 40 kg/m3 provided a hardening behavior for the FRCP, and could be considered as equivalent to the critical volume in this condition.


Author(s):  
Payal Sachdeva ◽  
A.B. Danie Roy ◽  
Naveen Kwatra

Headed bars (HB) with different head shapes (Square, Circular, and Rectangular) and bar diameters (db: 16, 20, and 25 mm) embedded in steel fiber reinforced concrete have been subjected to pull-out test. The influence of head shapes, concrete compressive strength (M20 and M40), db, and steel fibers (0, 0.5, 1, and 1.5%) on the anchorage capacity of HB have been evaluated. Numerical model for improving the anchorage capacity of HB has also been proposed. Results have revealed that the anchorage capacity of HB increases with the increase in concrete compressive strength, db, and steel fibers, which have been validated by non-linear regression analysis using dummy variables. Two failure modes namely, steel and concrete-blowout have been observed and the prevailing mode of failure is steel failure. Based on load-deflection curves and derived descriptive equations, it is observed that the circular HB has displayed the highest peak load.


Sign in / Sign up

Export Citation Format

Share Document