scholarly journals Automated Motion Analysis of Bony Joint Structures from Dynamic Computer Tomography Images: A Multi-Atlas Approach

Diagnostics ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 2062
Author(s):  
Benyameen Keelson ◽  
Luca Buzzatti ◽  
Jakub Ceranka ◽  
Adrián Gutiérrez ◽  
Simone Battista ◽  
...  

Dynamic computer tomography (CT) is an emerging modality to analyze in-vivo joint kinematics at the bone level, but it requires manual bone segmentation and, in some instances, landmark identification. The objective of this study is to present an automated workflow for the assessment of three-dimensional in vivo joint kinematics from dynamic musculoskeletal CT images. The proposed method relies on a multi-atlas, multi-label segmentation and landmark propagation framework to extract bony structures and detect anatomical landmarks on the CT dataset. The segmented structures serve as regions of interest for the subsequent motion estimation across the dynamic sequence. The landmarks are propagated across the dynamic sequence for the construction of bone embedded reference frames from which kinematic parameters are estimated. We applied our workflow on dynamic CT images obtained from 15 healthy subjects on two different joints: thumb base (n = 5) and knee (n = 10). The proposed method resulted in segmentation accuracies of 0.90 ± 0.01 for the thumb dataset and 0.94 ± 0.02 for the knee as measured by the Dice score coefficient. In terms of motion estimation, mean differences in cardan angles between the automated algorithm and manual segmentation, and landmark identification performed by an expert were below 1°. Intraclass correlation (ICC) between cardan angles from the algorithm and results from expert manual landmarks ranged from 0.72 to 0.99 for all joints across all axes. The proposed automated method resulted in reproducible and reliable measurements, enabling the assessment of joint kinematics using 4DCT in clinical routine.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Po-Ying Wu ◽  
Jo-Hsuan Wu ◽  
Yi-Ting Hsieh ◽  
Lin Chih-Chieh Chen ◽  
Ting Cheng ◽  
...  

AbstractThis study aimed to evaluate the reliability of in vivo confocal microscopic neuroanalysis by beginners using manual and automated modules. Images of sub-basal corneal nerve plexus (SCNP) from 108 images of 18 healthy participants were analyzed by 7 beginner observers using manual (CCMetrics, [CCM]) and automated (ACCMetrics, [ACCM]) module. SCNP parameters analyzed included corneal nerve fiber density (NFD), corneal nerve branch density (NBD), corneal nerve fiber length (NFL), and tortuosity coefficient (TC). The intra-observer repeatability, inter-observer reliability, inter-module agreement, and left–right eye symmetry level of SCNP parameters were examined. All observers showed good intra-observer repeatability using CCM (intraclass correlation coefficient [ICC] > 0.60 for all), except when measuring TC. Two observers demonstrated especially excellent repeatability in analyzing NFD, NBD, and NFL using manual mode, indicating the quality of interpretation may still be observer-dependent. Among all SCNP parameters, NFL had the best inter-observer reliability (Spearman’s rank-sum correlation coefficient [SpCC] and ICC > 0.85 for the 3 original observers) and left–right symmetry level (SpCC and ICC > 0.60). In the additional analysis of inter-observer reliability using results by all 7 observers, only NFL showed good inter-observer reliability (ICC = 0.79). Compared with CCM measurements, values of ACCM measurements were significantly lower, implying a poor inter-module agreement. Our result suggested that performance of quantitative corneal neuroanalysis by beginners maybe acceptable, with NFL being the most reliable parameter, and automated method cannot fully replace manual work.


2014 ◽  
Vol 120 (1) ◽  
pp. 86-96 ◽  
Author(s):  
Maarten van Eerd ◽  
Jacob Patijn ◽  
Judith M. Sieben ◽  
Mischa Sommer ◽  
Jan Van Zundert ◽  
...  

Abstract Background: Anatomical validation studies of cervical ultrasound images are sparse. Validation is crucial to ensure accurate interpretation of cervical ultrasound images and to develop standardized reliable ultrasound procedures to identify cervical anatomical structures. The aim of this study was to acquire validated ultrasound images of cervical bony structures and to develop a reliable method to detect and count the cervical segmental levels. Methods: An anatomical model of a cervical spine, embedded in gelatin, was inserted in a specially developed measurement device. This provided ultrasound images of cervical bony structures. Anatomical validation was achieved by laser light beams projecting the center of the ultrasound image on the cervical bony structures through a transparent gelatin. Results: Anatomically validated ultrasound images of different cervical bony structures were taken from dorsal, ventral, and lateral perspectives. Potentially relevant anatomical landmarks were defined and validated. Test/retest analysis for positioning showed a reproducibility with an intraclass correlation coefficient for single measures of 0.99. Besides providing validated ultrasound images of bony structures, this model helped to develop a method to detect and count the cervical segmental levels in vivo at long-axis position, in a dorsolateral (paramedian) view at the level of the laminae, starting from the base of the skull and sliding the ultrasound probe caudally. Conclusions: Ultrasound bony images of the cervical vertebrae were validated with an in vitro model. Anatomical bony landmarks are the mastoid process, the transverse process of C1, the tubercles of C6 and C7, and the cervical laminae. Especially, the cervical dorsal laminae serve best as anatomical bony landmarks to reliably detect the cervical segmental levels in vivo.


Author(s):  
Sanjana Baksi ◽  
Simon Freezer ◽  
Takeshi Matsumoto ◽  
Craig Dreyer

Summary Introduction Due to technological advances, the quantification of facial form can now be done via three-dimensional (3D) photographic systems such as stereophotogrammetry. To enable comparison with traditional cephalometry, soft-tissue anatomical landmark definitions have been modified to incorporate the third dimension. Annotating these landmarks manually, however, is still a time-consuming and arduous process. Objective To develop an automated algorithm to accurately identify anatomical landmarks on three-dimensional soft tissue images. Methods Thirty 3dMD images were selected from a private orthodontic practice consisting of 15 males and 15 females between 9 and 17 years of age. The soft-tissue 3D images were aligned along a reference plane to setup a Cartesian coordinate system. Screened by 2 observers, 21 landmarks were manually annotated and their coordinates defined. An automated landmark identification algorithm, based on their anatomical definitions, was developed to compare the landmark validity against the manually identified counterpart. Results Twenty-one landmarks were analysed in detail. Inter-observer and intra-observer reliability using ICC was >0.9. The average difference and standard deviation between manual and automated methods for all landmarks was 3.2 and 1.64 mm, respectively. Sixteen out of twenty-one landmarks had a mean difference less than 4 mm. The landmarks of greatest agreement (≤2 mm) were mainly in the midline: pronasale, subnasale, subspinale, labiale superius, stomion, with the exception of chelion right. Five linear facial measurements were found to have moderate to good agreement between the manual and automated identification methods. Conclusions The developed algorithm was determined to be clinically relevant in the detection of midsagittal landmarks and associated measurements within the studied sample of adolescent Caucasian subjects.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yoichi Shimizu ◽  
Yukihiro Nakai ◽  
Hiroyuki Watanabe ◽  
Shimpei Iikuni ◽  
Masahiro Ono ◽  
...  

Abstract Background [18F]Fluoromisonidazole ([18F]FMISO) is a PET imaging probe widely used for the detection of hypoxia. We previously reported that [18F]FMISO is metabolized to the glutathione conjugate of the reduced form in hypoxic cells. In addition, we found that the [18F]FMISO uptake level varied depending on the cellular glutathione conjugation and excretion ability such as enzyme activity of glutathione-S-transferase and expression levels of multidrug resistance-associated protein 1 (MRP1, an efflux transporter), in addition to the cellular hypoxic state. In this study, we evaluated whether MRP1 activity affected [18F]FMISO PET imaging. Methods FaDu human pharyngeal squamous cell carcinoma cells were pretreated with MRP1 inhibitors (cyclosporine A, lapatinib, or MK-571) for 1 h, incubated with [18F]FMISO for 4 h under hypoxia, and their radioactivity was then measured. FaDu tumor-bearing mice were intravenously injected with [18F]FMISO, and PET/CT images were acquired at 4 h post-injection (1st PET scan). Two days later, the same mice were pretreated with MRP1 inhibitors (cyclosporine A, lapatinib, or MK-571) for 1 h, and PET/CT images were acquired (2nd PET scan). Results FaDu cells pretreated with MRP1 inhibitors exhibited significantly higher radioactivity than those without inhibitor treatment (cyclosporine A: 6.91 ± 0.27, lapatinib: 10.03 ± 0.47, MK-571: 10.15 ± 0.44%dose/mg protein, p < 0.01). In the in vivo PET study, the SUVmean ratio in tumors [calculated as after treatment (2nd PET scan)/before treatment of MRP1 inhibitors (1st PET scan)] of the mice treated with MRP1 inhibitors was significantly higher than those of control mice (cyclosporine A: 2.6 ± 0.7, lapatinib: 2.2 ± 0.7, MK-571: 2.2 ± 0.7, control: 1.2 ± 0.2, p < 0.05). Conclusion In this study, we revealed that MRP1 inhibitors increase [18F]FMISO accumulation in hypoxic cells. This suggests that [18F]FMISO-PET imaging is affected by MRP1 inhibitors independent of the hypoxic state.


2021 ◽  
Vol 12 (3) ◽  
pp. 44
Author(s):  
Leyla Hasandoost ◽  
Daniella Marx ◽  
Paul Zalzal ◽  
Oleg Safir ◽  
Mark Hurtig ◽  
...  

Poly(methyl methacrylate) (PMMA) is used to manage bone loss in revision total knee arthroplasty (rTKA). However, the application of PMMA has been associated with complications such as volumetric shrinkage, necrosis, wear debris, and loosening. Glass polyalkenoate cements (GPCs) have potential bone cementation applications. Unlike PMMA, GPC does not undergo volumetric shrinkage, adheres chemically to bone, and does not undergo an exothermic setting reaction. In this study, two different compositions of GPCs (GPCA and GPCB), based on the patented glass system SiO2-CaO-SrO-P2O5-Ta2O5, were investigated. Working and setting times, pH, ion release, compressive strength, and cytotoxicity of each composition were assessed, and based on the results of these tests, three sets of samples from GPCA were implanted into the distal femur and proximal tibia of three sheep (alongside PMMA as control). Clinical CT scans and micro-CT images obtained at 0, 6, and 12 weeks revealed the varied radiological responses of sheep bone to GPCA. One GPCA sample (implanted in the sheep for 12 weeks) was characterized with no bone resorption. Furthermore, a continuous bone–cement interface was observed in the CT images of this sample. The other implanted GPCA showed a thin radiolucent border at six weeks, indicating some bone resorption occurred. The third sample showed extensive bone resorption at both six and 12 weeks. Possible speculative factors that might be involved in the varied response can be: excessive Zn2+ ion release, low pH, mixing variability, and difficulty in inserting the samples into different parts of the sheep bone.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Pieter-Jan Verhelst ◽  
H. Matthews ◽  
L. Verstraete ◽  
F. Van der Cruyssen ◽  
D. Mulier ◽  
...  

AbstractAutomatic craniomaxillofacial (CMF) three dimensional (3D) dense phenotyping promises quantification of the complete CMF shape compared to the limiting use of sparse landmarks in classical phenotyping. This study assesses the accuracy and reliability of this new approach on the human mandible. Classic and automatic phenotyping techniques were applied on 30 unaltered and 20 operated human mandibles. Seven observers indicated 26 anatomical landmarks on each mandible three times. All mandibles were subjected to three rounds of automatic phenotyping using Meshmonk. The toolbox performed non-rigid surface registration of a template mandibular mesh consisting of 17,415 quasi landmarks on each target mandible and the quasi landmarks corresponding to the 26 anatomical locations of interest were identified. Repeated-measures reliability was assessed using root mean square (RMS) distances of repeated landmark indications to their centroid. Automatic phenotyping showed very low RMS distances confirming excellent repeated-measures reliability. The average Euclidean distance between manual and corresponding automatic landmarks was 1.40 mm for the unaltered and 1.76 mm for the operated sample. Centroid sizes from the automatic and manual shape configurations were highly similar with intraclass correlation coefficients (ICC) of > 0.99. Reproducibility coefficients for centroid size were < 2 mm, accounting for < 1% of the total variability of the centroid size of the mandibles in this sample. ICC’s for the multivariate set of 325 interlandmark distances were all > 0.90 indicating again high similarity between shapes quantified by classic or automatic phenotyping. Combined, these findings established high accuracy and repeated-measures reliability of the automatic approach. 3D dense CMF phenotyping of the human mandible using the Meshmonk toolbox introduces a novel improvement in quantifying CMF shape.


2021 ◽  
Vol 11 (9) ◽  
pp. 3947
Author(s):  
Marco Farronato ◽  
Gianluca M. Tartaglia ◽  
Cinzia Maspero ◽  
Luigi M. Gallo ◽  
Vera Colombo

Clinical use of portable optical tracking system in dentistry could improve the analysis of mandibular movements for diagnostic and therapeutic purposes. A new workflow for the acquisition of mandibular kinematics was developed. Reproducibility of measurements was tested in vitro and intra- and inter-rater repeatability were assessed in vivo in healthy volunteers. Prescribed repeated movements (n = 10) in three perpendicular directions of the tracking-device coordinate system were performed. Measurement error and coefficient of variation (CV) among repetitions were determined. Mandibular kinematics of maximum opening, left and right laterality, protrusion and retrusion of five healthy subjects were recorded in separate sessions by three different operators. Obtained records were blindly examined by three observers. Intraclass correlation coefficient (ICC) was calculated to estimate inter-rater and intra-rater reliability. Maximum in vitro measurement error was 0.54 mm and CV = 0.02. Overall, excellent intra-rater reliability (ICC > 0.90) for each variable, general excellent intra-rater reliability (ICC = 1.00) for all variables, and good reliability (ICC > 0.75) for inter-rater tests were obtained. A lower score was obtained for retrusion with “moderate reliability” (ICC = 0.557) in the inter-rater tests. Excellent repeatability and reliability in optical tracking of primary movements were observed using the tested portable tracking device and the developed workflow.


2010 ◽  
Vol 19 (08) ◽  
pp. 1665-1687 ◽  
Author(s):  
MOHAMMAD REZA HOSSEINY FATEMI ◽  
HASAN F. ATES ◽  
ROSLI SALLEH

The sub-pixel motion estimation (SME), together with the interpolation of reference frames, is a computationally extensive part of the H.264 encoder that increases the memory requirement 16-times for each reference frame. Due to the huge computational complexity and memory requirement of the H.264 SME, its hardware architecture design is an important issue especially in high resolution or low power applications. To solve the above difficulties, we propose several optimization techniques in both algorithm and architecture levels. In the algorithm level, we propose a parabolic based algorithm for SME with quarter-pixel accuracy which reduces the computational budget by 94.35% and the memory access requirement by 98.5% in comparison to the standard interpolate and search method. In addition, a fast version of the proposed algorithm is presented that reduces the computational budget 46.28% further while maintaining the video quality. In the architecture level, we propose a novel bit-serial architecture for our algorithm. Due to advantages of the bit-serial architecture, it has a low gate count, high speed operation frequency, low density interconnection, and a reduced number of I/O pins. Also, several optimization techniques including the sum of absolute differences truncation, source sharing exploiting and power saving techniques are applied to the proposed architecture which reduce power consumption and area. Our design can save between 57.71–90.01% of area cost and improves the macroblock (MB) processing speed between 1.7–8.44 times when compared to previous designs. Implementation results show that our design can support real time HD1080 format with 20.3 k gate counts at the operation frequency of 144.9 MHz.


2016 ◽  
Author(s):  
Ting Xu ◽  
Alexander Opitz ◽  
R. Cameron Craddock ◽  
Margaret Wright ◽  
Xi-Nian Zuo ◽  
...  

AbstractResting state fMRI (R-fMRI) is a powerful in-vivo tool for examining the functional architecture of the human brain. Recent studies have demonstrated the ability to characterize transitions between functionally distinct cortical areas through the mapping of gradients in intrinsic functional connectivity (iFC) profiles. To date, this novel approach has primarily been applied to iFC profiles averaged across groups of individuals, or in one case, a single individual scanned multiple times. Here, we used a publically available R-fMRI dataset, in which 30 healthy participants were scanned 10 times (10 minutes per session), to investigate differences in full-brain transition profiles (i.e., gradient maps, edge maps) across individuals, and their reliability. 10-minute R-fMRI scans were sufficient to achieve high accuracies in efforts to “fingerprint” individuals based upon full-brain transition profiles. Regarding testretest reliability, the image-wise intraclass correlation coefficient (ICC) was moderate, and vertex-level ICC varied depending on region; larger durations of data yielded higher reliability scores universally. Initial application of gradient-based methodologies to a recently published dataset obtained from twins suggested inter-individual variation in areal profiles might have genetic and familial origins. Overall, these results illustrate the utility of gradient-based iFC approaches for studying inter-individual variation in brain function.