scholarly journals Exploiting Coarse-Grained Parallelism Using Cloud Computing in Massive Power Flow Computation

Energies ◽  
2018 ◽  
Vol 11 (9) ◽  
pp. 2268 ◽  
Author(s):  
Dong-Hee Yoon ◽  
Sang-Kyun Kang ◽  
Minseong Kim ◽  
Youngsun Han

We present a novel architecture of parallel contingency analysis that accelerates massive power flow computation using cloud computing. It leverages cloud computing to investigate huge power systems of various and potential contingencies. Contingency analysis is undertaken to assess the impact of failure of power system components; thus, extensive contingency analysis is required to ensure that power systems operate safely and reliably. Since many calculations are required to analyze possible contingencies under various conditions, the computation time of contingency analysis increases tremendously if either the power system is large or cascading outage analysis is needed. We also introduce a task management optimization to minimize load imbalances between computing resources while reducing communication and synchronization overheads. Our experiment shows that the proposed architecture exhibits a performance improvement of up to 35.32× on 256 cores in the contingency analysis of a real power system, i.e., KEPCO2015 (the Korean power system), by using a cloud computing system. According to our analysis of the task execution behaviors, we confirmed that the performance can be enhanced further by employing additional computing resources.

Energies ◽  
2020 ◽  
Vol 13 (9) ◽  
pp. 2147
Author(s):  
Dong-Hee Yoon ◽  
Youngsun Han

A power flow study aims to analyze a power system by obtaining the voltage and phase angle of buses inside the power system. Power flow computation basically uses a numerical method to solve a nonlinear system, which takes a certain amount of time because it may take many iterations to find the final solution. In addition, as the size and complexity of power systems increase, further computational power is required for power system study. Therefore, there have been many attempts to conduct power flow computation with large amounts of data using parallel computing to reduce the computation time. Furthermore, with recent system developments, attempts have been made to increase the speed of parallel computing using graphics processing units (GPU). In this review paper, we summarize issues related to parallel processing in power flow studies and analyze research into the performance of fast power flow computations using parallel computing methods with GPU.


2012 ◽  
Vol 2012 ◽  
pp. 1-19
Author(s):  
G. Ozdemir Dag ◽  
Mustafa Bagriyanik

The unscheduled power flow problem needs to be minimized or controlled as soon as possible in a deregulated power system since the transmission systems are mostly operated at their power-carrying limits or very close to it. The time spent for simulations to determine the current states of all the system and control variables of the interconnected power system is important. Taking necessary action in case of any failure of equipment or any other occurrence of an undesired situation could be critical. Using supercomputing facilities and parallel computing techniques together decreases the computation time greatly. In this study, a parallel implementation of a multiobjective optimization approach based on both genetic algorithms and fuzzy decision making to manage unscheduled flows is presented. Parallel computation techniques are applied using supercomputers (high-performance computers). The proposed method is applied to the IEEE 300 bus test system. Two different cases for some parameters of GA are considered to see the power of parallel computation technique. Then the simulation results are presented.


Energies ◽  
2021 ◽  
Vol 14 (17) ◽  
pp. 5382
Author(s):  
Vedik Basetti ◽  
Shriram S. Rangarajan ◽  
Chandan Kumar Shiva ◽  
Sumit Verma ◽  
Randolph E. Collins ◽  
...  

Load flow analysis is an essential tool for the reliable planning and operation of interconnected power systems. The constant increase in power demand, apart from the increased intermittency in power generation due to renewable energy sources without proportionate augmentation in transmission system infrastructure, has driven the power systems to function nearer to their limits. Though the power flow (PF) solution may exist in such circumstances, the traditional Newton–Raphson based PF techniques may fail due to computational difficulties owing to the singularity of the Jacobian Matrix during critical conditions and faces difficulties in solving ill-conditioned systems. To address these problems and to assess the impact of large-scale photovoltaic generator (PVG) integration in power systems on power flow studies, a derivative-free quasi-oppositional heap-based optimization (HBO) (QOHBO) technique is proposed in the present paper. In the proposed approach, the concept of quasi-oppositional learning is applied to HBO to enhance the convergence speed. The efficacy and effectiveness of the proposed QOHBO-PF technique are verified by applying it to the standard IEEE and ill-conditioned systems. The robustness of the algorithm is validated under the maximum loadability limits and high R/X ratios, comparing the results with other well-known methods suggested in the literature. The results thus obtained show that the proposed QOHBO-PF technique has less computation time, further enhancement of reliability in the presence of PVG, and has the ability to provide multiple PF solutions that can be utilized for voltage stability analysis.


In power systems, voltage stability perform the major role in design and its operation. Major system failures are occur due to voltage variability and breakdown. To meet and compensate the rising power demand of regular usage in modern trends, transmission networks are enormously loaded which create the voltage instability. Contingency analysis is a recognized energy managing tool. It calculate the violation in the transmission line. In this paper a computational controller fuzzy system is suggested to handle the transmission line outage and overload in other branch kind of problems in Power system. The efficiency of power transmission system with fuzzy controller is inveterate by computation of various parameters of transmission bus under different loading situations. For the contingency analysis the transmission power flow several methods have been developed. Fast Decoupled load flow program is the effective method which provides a fast and effective solution to the contingency analysis in the transmission system and also it is incorporate with matrix alteration formula which gives additional advantage for the system.


Energies ◽  
2019 ◽  
Vol 12 (2) ◽  
pp. 322 ◽  
Author(s):  
Ping He ◽  
Seyed Arefifar ◽  
Congshan Li ◽  
Fushuan Wen ◽  
Yuqi Ji ◽  
...  

The well-developed unified power flow controller (UPFC) has demonstrated its capability in providing voltage support and improving power system stability. The objective of this paper is to demonstrate the capability of the UPFC in mitigating oscillations in a wind farm integrated power system by employing eigenvalue analysis and dynamic time-domain simulation approaches. For this purpose, a power oscillation damping controller (PODC) of the UPFC is designed for damping oscillations caused by disturbances in a given interconnected power system, including the change in tie-line power, the changes of wind power outputs, and others. Simulations are carried out for two sample power systems, i.e., a four-machine system and an eight-machine system, for demonstration. Numerous eigenvalue analysis and dynamic time-domain simulation results confirm that the UPFC equipped with the designed PODC can effectively suppress oscillations of power systems under various disturbance scenarios.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 737
Author(s):  
Michał Kosmecki ◽  
Robert Rink ◽  
Anna Wakszyńska ◽  
Roberto Ciavarella ◽  
Marialaura Di Somma ◽  
...  

Along with the increasing share of non-synchronous power sources, the inertia of power systems is being reduced, which can give rise to frequency containment problems should an outage of a generator or a power infeed happen. Low system inertia is eventually unavoidable, thus power system operators need to be prepared for this condition. This paper addresses the problem of low inertia in the power system from two different perspectives. At a system level, it proposes an operation planning methodology, which utilises a combination of power flow and dynamic simulation for calculation of existing inertia and, if need be, synthetic inertia (SI) to fulfil the security criterion of adequate rate of change of frequency (RoCoF). On a device level, it introduces a new concept for active power controller, which can be applied virtually to any power source with sufficient response time to create synthetic inertia. The methodology is demonstrated for a 24 h planning period, for which it proves to be effective. The performance of SI controller activated in a battery energy storage system (BESS) is positively validated using a real-time digital simulator (RTDS). Both proposals can effectively contribute to facilitating the operation of low inertia power systems.


Load frequency control (LFC) in interconnected power system of small distribution generation (DG) for reliability in distribution system. The main objective is to performance evaluation load frequency control of hybrid for interconnected two-area power systems. The simulation consist of solar farm 10 MW and gasifier plant 300 kW two-area in tie line. This impact LFC can be address as a problem on how to effectively utilize the total tie-line power flow at small DG. To performance evaluation and improve that defect of LFC, the power flow of two-areas LFC system have been carefully studied, such that, the power flow and power stability is partially LFC of small DG of hybrid for interconnected two-areas power systems. Namely, the controller and structural properties of the multi-areas LFC system are similar to the properties of hybrid for interconnected two-area LFC system. Inspired by the above properties, the controller that is propose to design some proportional-integral-derivative (PID) control laws for the two-areas LFC system successfully works out the aforementioned problem. The power system of renewable of solar farm and gasifier plant in interconnected distribution power system of area in tie – line have simulation parameter by PID controller. Simulation results showed that 3 types of the controller have deviation frequency about 0.025 Hz when tie-line load changed 1 MW and large disturbance respectively. From interconnected power system the steady state time respond is 5.2 seconds for non-controller system, 4.3 seconds for automatic voltage regulator (AVR) and 1.4 seconds for under controlled system at 0.01 per unit (p.u.) with PID controller. Therefore, the PID control has the better efficiency non-controller 28 % and AVR 15 %. The result of simulation in research to be interconnected distribution power system substation of area in tie - line control for little generate storage for grid connected at better efficiency and optimization of renewable for hybrid. It can be conclude that this study can use for applying to the distribution power system to increase efficiency and power system stability of area in tie – line.


Author(s):  
Isaiah Adebayo ◽  
Adisa Jimoh ◽  
Adedayo Yusuff

AbstractThis paper proposes two techniques for the identification of critical buses in a power system. The technique of Network Structural Theory Participation Factor (NSTPF) depends on the network structural interconnection of buses as captured by the admittance matrix of the system and is formulated based on the fundamental circuit theory law using eigenvalue decomposition method. Another power flow based technique which depends on the system maximum loadability, the system step size among other factors is also proposed. Traditional power flow based techniques are used as benchmarks to determine the significance of the proposed methods. To ensure voltage stability enhancement, STATCOM FACTS device is installed at the selected weak load buses of the practical Nigerian 24 bus and IEEE 30 bus test systems. The results of the simulation obtained show that, the suggested approach of NSTPF is more suitable in the identification of weak buses that are liable to voltage instability in power systems as it requires less computational burden and also saves time compared to techniques based on power flow solutions.


Sign in / Sign up

Export Citation Format

Share Document