scholarly journals Flexibility Services to Minimize the Electricity Production from Fossil Fuels. A Case Study in a Mediterranean Small Island

Energies ◽  
2019 ◽  
Vol 12 (18) ◽  
pp. 3492 ◽  
Author(s):  
Crainz ◽  
Curto ◽  
Franzitta ◽  
Longo ◽  
Montana ◽  
...  

The design of multi-carrier energy systems (MESs) has become increasingly important in the last decades, due to the need to move towards more efficient, flexible, and reliable power systems. In a MES, electricity, heating, cooling, water, and other resources interact at various levels, in order to get optimized operation. The aim of this study is to identify the optimal combination of components, their optimal sizes, and operating schedule allowing minimizing the annual cost for meeting the energy demand of Pantelleria, a Mediterranean island. Starting from the existing energy system (comprising diesel generators, desalination plant, freshwater storage, heat pumps, and domestic hot water storages) the installation of solar resources (photovoltaic and solar thermal) and electrical storage were considered. In this way, the optimal scheduling of storage units injections, water desalination operation, and domestic hot water production was deduced. An energy hub model was implemented using MATLAB to represent the problem. All equations in the model are linear functions, and variables are real or integer. Thus, a mixed integer linear programming algorithm was used for the solution of the optimization problem. Results prove that the method allows a strong reduction of operating costs of diesel generators also in the existing configuration.

Energies ◽  
2019 ◽  
Vol 12 (20) ◽  
pp. 3841 ◽  
Author(s):  
Szymon Firląg

The main objective of this article is to propose possible requirements for cost-optimal plus energy building in a cold, heating dominated climate. The open question is what is more cost-effective: reduction of energy demand or increase of production from renewable energy sources. The target of the research was to check which solution has the lowest investment and maintenance costs. The analysis was made for a single-family house located in central Poland, including three different energy standards: WT2021 with energy need for heating ≤100 kWh/(m² year), NF40 with energy need for heating ≤40 kWh/(m² year) and NF15 with energy need for heating ≤15 kWh/(m² year)). Air and ground source heat pumps were used as a heat source and a photovoltaic system for the production of the electrical energy. For each case the investment and running costs were calculated very precisely, taking into account heating, ventilation, domestic hot water and auxiliary systems. Global cost for a 30-year period showed that house variants with air source heat pumps are more cost effective. The investment, replacement and maintenance cost related with energy systems have the biggest share in the global cost. Reaching the plus energy standard was possible only in the case of low-energy standard NF40 and NF15. Based on this research the proposed requirements for plus energy single-family residential buildings in central Poland are the following: the final (delivered) electrical energy demand (including heating, ventilation, domestic hot water and auxiliary systems) <45 kWh/(m² year) and the on-site electrical energy production >45 kWh/(m² year).


2012 ◽  
Vol 30 ◽  
pp. 101-105 ◽  
Author(s):  
Andreas Genkinger ◽  
Ralf Dott ◽  
Thomas Afjei

2019 ◽  
Vol 100 ◽  
pp. 00057
Author(s):  
Elżbieta Niemierka ◽  
Piotr Jadwiszczak

Ever-increasing power market and environmental policy enforce growth of renewable power sources. Renewables inflexibility and dependency on weather condition causes periodically imbalance in power system due to the green power overproduction. With the increase of renewable sources, the balancing problems in power system will be increasingly significance issue. It is proposed to use individual heat pumps as a next tool for energy system adjustment support. Power system adjustment will be carried out by active demand side management by intended domestic hot water tanks overheating. The smart grid individual heat pumps setpoints will be switched at community or even country scale. The strategy allows shaving the overproduction peaks through short-term increase of electricity consumption in remote controlled heat pumps and to lowering power demand during green power deficits using the thermal energy stored in overheated domestic hot water. The dynamic mathematical simulations were made to define the operation and limitation of active control strategy of heat pumps integrated into smart grid. The results allow testing and assessing the potential of individual heat pumps as a next tool for balancing the power system with large scale of renewable power.


2020 ◽  
Vol 160 ◽  
pp. 01004 ◽  
Author(s):  
Stanislav Chicherin ◽  
Lyazzat Junussova ◽  
Timur Junussov

Proper adjustment of domestic hot water (DHW) load structure can balance energy demand with the supply. Inefficiency in primary energy use prompted Omsk DH company to be a strong proponent of a flow controller at each substation. Here the return temperature is fixed to the lowest possible value and the supply temperature is solved. Thirty-five design scenarios are defined for each load deviation index with equally distributed outdoor temperature ranging from +8 for the start of a heating season towards extreme load at temperature of -26°C. All the calculation results are listed. If a flow controller is installed, the customers might find it suitable to switch to this type of DHW supply. Considering an option with direct hot water extraction as usual and a flow controller installed, the result indicates that the annual heat consumption will be lower once network temperatures during the fall or spring months are higher. The heat load profiles obtained here may be used as input for a simulation of a DH substation, including a heat pump and a tank for thermal energy storage. This design approach offers a quantitative way of sizing temperature levels in each DH system according to the listed methodology and the designer's preference.


2019 ◽  
Vol 11 (8) ◽  
pp. 2433
Author(s):  
Jesica Fernández-Agüera ◽  
Samuel Domínguez-Amarillo ◽  
Miguel Ángel Campano

Social housing dating from the postwar years through the end of the twentieth century is one of the major stores of European cities’ residential stock. As it is generally characterised by a poor thermal performance and an inefficient control of energy consumption, it constitutes one of the main targets for residential heritage renewal. This study aimed to locate and quantify air leaks across building envelopes in Mediterranean multifamily housing with a view to curbing the uncontrolled inflow of outdoor air that has a direct impact on occupant comfort and housing energy demand. Airtightness tests conducted in a series of protocols to quantify draught across envelope elements were supplemented with qualitative infrared thermographic and smoke tests to locate leakage pathways. Air was found to flow mainly across façade enclosures, primarily around openings, as well as through service penetrations in walls between flats and communal areas accommodating electrical and telecommunication wires and water supply, domestic hot water (DHW), and drainage pipes. The general absence of evidence of draught across structural floors or inter-flat partitions was consistent with the construction systems in place.


2020 ◽  
Vol 12 (15) ◽  
pp. 6071
Author(s):  
Nikola Pokorny ◽  
Tomáš Matuška

Photovoltaic–thermal collector generates electrical and thermal energy simultaneously from the same area. In this paper performance analysis of a potentially very promising application of a glazed photovoltaic–thermal collector for domestic hot water preparation in multifamily building is presented. Solar system in multifamily building can be installed on the roof or integrated in the façade of the building. The aim of this simulation study is to show difference of thermal and electrical performance between façade and roof installation of a glazed photovoltaic-thermal collectors at three European locations. Subsequently, this study shows benefit of photovoltaic-thermal collector installation in comparison with side-by-side installation of conventional system. For the purpose of simulation study, mathematical model of glazed photovoltaic-thermal collector has been experimentally validated and implemented into TRNSYS. A solar domestic hot water system with photovoltaic–thermal collectors generates more electrical and thermal energy in comparison with a conventional system across the whole of Europe for a particular installation in a multifamily building. The specific thermal yield of the photovoltaic–thermal system ranges between 352 and 582 kWh/m2. The photovoltaic–thermal system electric yield ranges between 63 and 149 kWh/m2. The increase in electricity production by the photovoltaic–thermal system varies from 19% to 32% in comparison with a conventional side-by-side system. The increase in thermal yield differs between the façade and roof alternatives. Photovoltaic-thermal system installation on the roof has higher thermal yield than conventional system and the increase of thermal yield ranges from 37% to 53%. The increase in thermal yield of façade photovoltaic-thermal system is significantly higher in comparison with a conventional system and ranges from 71% to 81%.


2019 ◽  
Vol 11 (3) ◽  
pp. 599 ◽  
Author(s):  
Francisco Díaz Pérez ◽  
Ricardo Díaz Martín ◽  
Francisco Pérez Trujillo ◽  
Moises Díaz ◽  
Adib Mouhaffel

We analyze the energy consumption of domestic hot water (DHW) in the hotels of the archipelago of the Canary Islands (Spain). Currently, systems use fossil fuels of propane and gas oil. However, this paper analyzes several alternative systems which focus on renewable and mixed energies, such as biomass, solar thermal and heat pumps systems associated with an electric generation with photovoltaic solar panels for self-consumption. The carbon footprint generated is calculated for each method of generation of DHW. In our analysis, we demonstrate that by using a high-temperature heat pump with an average coefficient of performance (COP) equal to or greater than 4.4 associated with photovoltaic solar panels, a zero-emission domestic hot water system can be achieved, when the installation area of the photovoltaic solar panels is equal to that of the solar thermal system. The importance of DHW’s carbon footprint is proven, as is the efficiency of using high-temperature heat pumps associated with photovoltaic solar panels. As such, such mixed system suggests that the generation of DHW would have zero emissions with maximum annual savings according to hotel occupancy, between 112,417 and 137,644 tons of carbon dioxide (CO2), compared to current boilers based on fossil fuels.


Sign in / Sign up

Export Citation Format

Share Document