scholarly journals A GIS-Based Planning Approach for Urban Power and Natural Gas Distribution Grids with Different Heat Pump Scenarios

Energies ◽  
2020 ◽  
Vol 13 (16) ◽  
pp. 4052 ◽  
Author(s):  
Jolando M. Kisse ◽  
Martin Braun ◽  
Simon Letzgus ◽  
Tanja M. Kneiske

Next to building insulation, heat pumps driven by electrical compressors (eHPs) or by gas engines (geHPs) can be used to reduce primary energy demand for heating. They come with different investment requirements, operating costs and emissions caused. In addition, they affect both the power and gas grids, which necessitates the assessment of both infrastructures regarding grid expansion planning. To calculate costs and CO2 emissions, 2000 electrical load profiles and 180 different heat demand profiles for single-family homes were simulated and heat pump models were applied. In a case study for a neighborhood energy model, the load profiles were assigned to buildings in an example town using public data on locations, building age and energetic refurbishment variants. In addition, the town’s gas distribution network and low voltage grid were modeled. Power and gas flows were simulated and costs for required grid extensions were calculated for 11% and 16% heat pump penetration. It was found that eHPs have the highest energy costs but will also have the lowest CO2 emissions by 2030 and 2050. For the investigated case, power grid investments of 11,800 euros/year are relatively low compared to gas grid connection costs of 70,400 euros/year. If eHPs and geHPs are combined, a slight reduction of overall costs is possible, but emissions would rise strongly compared to the all-electric case.

2019 ◽  
Vol 116 ◽  
pp. 00084
Author(s):  
Krystian Szczerbak

The climate in Poland is slightly disparate in each region. The differences in temperature not always come along with the intensity of solar radiation in 5 climate zones. South of the country is colder, but well irradiated by the Sun and northern regions have milder climate, but are less irradiated. This fact alone makes people consider the suitability and safety of using renewable energy sources such as air-to-water heat pumps, solar collectors and photovoltaics instead of more traditional, fossil fuel powered sources. This paper presents a comparison analysis of energy demand and the cost for heating in a group of single-family buildings by 4 variants (gas boiler, gas boiler and solar collectors, air-to-water heat pump, air-to-water heat pump and photovoltaics) in 5 chosen cities in each polish climate zone. Calculations were done for space heating and domestic hot water energy demand, CO2 emissions and cumulative costs for all variants and locations. The results confirm the inconsistency of polish climate and have shown profitability and utility of renewable energy sources.


2012 ◽  
Vol 9 (2) ◽  
pp. 65
Author(s):  
Alhassan Salami Tijani ◽  
Nazri Mohammed ◽  
Werner Witt

Industrial heat pumps are heat-recovery systems that allow the temperature ofwaste-heat stream to be increased to a higher, more efficient temperature. Consequently, heat pumps can improve energy efficiency in industrial processes as well as energy savings when conventional passive-heat recovery is not possible. In this paper, possible ways of saving energy in the chemical industry are considered, the objective is to reduce the primary energy (such as coal) consumption of power plant. Particularly the thermodynamic analyses ofintegrating backpressure turbine ofa power plant with distillation units have been considered. Some practical examples such as conventional distillation unit and heat pump are used as a means of reducing primary energy consumption with tangible indications of energy savings. The heat pump distillation is operated via electrical power from the power plant. The exergy efficiency ofthe primary fuel is calculated for different operating range ofthe heat pump distillation. This is then compared with a conventional distillation unit that depends on saturated steam from a power plant as the source of energy. The results obtained show that heat pump distillation is an economic way to save energy if the temperaturedifference between the overhead and the bottom is small. Based on the result, the energy saved by the application of a heat pump distillation is improved compared to conventional distillation unit.


Author(s):  
Mohammad Omar Temori ◽  
František Vranay

In this work, a mini review of heat pumps is presented. The work is intended to introduce a technology that can be used to income energy from the natural environment and thus reduce electricity consumption for heating and cooling. A heat pump is a mechanical device that transfers heat from one environmental compartment to another, typically against a temperature gradient (i.e. from cool to hot). In order to do this, an energy input is required: this may be mechanical, electrical or thermal energy. In most modern heat pumps, electrical energy powers a compressor, which drives a compression - expansion cycle of refrigerant fluid between two heat exchanges: a cold evaporator and a warm condenser. The efficiency or coefficient of performance (COP), of a heat pump is defined as the thermal output divided by the primary energy (electricity) input. The COP decreases as the temperature difference between the cool heat source and the warm heat sink increases. An efficient ground source heat pump (GSHP) may achieve a COP of around 4. Heat pumps are ideal for exploiting low-temperature environmental heat sources: the air, surface waters or the ground. They can deliver significant environmental (CO2) and cost savings.


Author(s):  
Praveen Cheekatamarla ◽  
Vishaldeep Sharma ◽  
Bo Shen

Abstract Economic and population growth is leading to increased energy demand across all sectors – buildings, transportation, and industry. Adoption of new energy consumers such as electric vehicles could further increase this growth. Sensible utilization of clean renewable energy resources is necessary to sustain this growth. Thermal needs in a building pose a significant challenge to the energy infrastructure. Supporting the current and future building thermal energy needs to offset the total electric demand while lowering the carbon footprint and enhancing the grid flexibility is presented in this study. Performance assessment of heat pumps, renewable energy, non-fossil fuel-based cogeneration systems, and their hybrid configurations was conducted. The impact of design configuration, coefficient of performance (COP), electric grid's primary energy efficiency on the key attributes of total carbon footprint, life cycle costs, operational energy savings, and site-specific primary energy efficiency are analyzed and discussed in detail.


2018 ◽  
Vol 70 ◽  
pp. 01001
Author(s):  
Jacek Biskupski

This paper gives a thorough description of the two different scenarios of retrofit of an existing detached country house (with high primary energy demand) to a net zero energy building (nZEB) or near zero energy (nearZEB) by using energy form on-site RES. Using a designed piece of modelling software author pointed out two possible solutions. First one, based on a bio boiler and small on-site PV generator (on-grid) and the other based on large PV generator and three heat pumps. A 24 months test was performed in order to find out the output of both scenarios. In first period, the bio boiler delivered energy for space heating and DHW, while energy from PV was used to cover all electricity needs of the household during the 12 months testing period. In the later, the energy received from 10 kWp PV of was partly used to cover the current needs of the entire household (switchable on/off-grid system), and surplus was stored in the national electricity grid and regained later in the winter for the space heating (by a GSHP) and ventilation (ASHP) and DHW (dedicated ASHP). In both cases the system proofed the possibility to achieve the nZEB (nearZEB in first scenario) state of the household, as all (in the first near all) energy needs were covered by renewable energy produced on-site.


Energies ◽  
2019 ◽  
Vol 12 (13) ◽  
pp. 2496 ◽  
Author(s):  
Laura Carnieletto ◽  
Borja Badenes ◽  
Marco Belliardi ◽  
Adriana Bernardi ◽  
Samantha Graci ◽  
...  

The design of ground source heat pumps is a fundamental step to ensure the high energy efficiency of heat pump systems throughout their operating years. To enhance the diffusion of ground source heat pump systems, two different tools are developed in the H2020 research project named, “Cheap GSHPs”: A design tool and a decision support system. In both cases, the energy demand of the buildings may not be calculated by the user. The main input data, to evaluate the size of the borehole heat exchangers, is the building energy demand. This paper presents a methodology to correlate energy demand, building typologies, and climatic conditions for different types of residential buildings. Rather than envelope properties, three insulation levels have been considered in different climatic conditions to set up a database of energy profiles. Analyzing European climatic test reference years, 23 locations have been considered. For each location, the overall energy and the mean hourly monthly energy profiles for heating and cooling have been calculated. Pre-calculated profiles are needed to size generation systems and, in particular, ground source heat pumps. For this reason, correlations based on the degree days for heating and cooling demand have been found in order to generalize the results for different buildings. These correlations depend on the Köppen–Geiger climate scale.


Energies ◽  
2020 ◽  
Vol 13 (17) ◽  
pp. 4337
Author(s):  
Daniel González-Prieto ◽  
Yolanda Fernández-Nava ◽  
Elena Marañón ◽  
Maria Manuela Prieto

The use of lightweight concrete for the construction of single-family houses has become increasingly popular in Spain. In this paper, single-family houses with different shape factors and window-to-wall ratios are analysed from both a thermal and environmental perspective using Passive House Planning Package (PHPP) software to calculate the energy demand. The study has been carried out for different Atlantic microclimates (coastal, inland, and mountain) in northern Spain. What most affects the thermal energy used for air conditioning is the variation of the microclimates, so the study focuses mainly on this aspect. Operational energy for heating has decreased greatly via the use of high degree of insulation and hence the next task is to decrease the total energy consumed taking into account the embodied energy. Impacts on Primary Energy and Global Warming Potential are calculated using a cradle-to-grave approach. The energy use for heating and domestic hot water is analysed for different thicknesses of insulation under three energy supply scenarios: electricity only (for 2018 and with the Spanish decarbonisation plan for 2030); heat pump plus electricity; and natural gas boiler. Even for houses with a good level of insulation, the ratio of operational-to-total impacts varies significantly: from 46% to 87% for primary energy and from 31% to 75% for global warming potential, depending on the shape factor of the house, the microclimate and the heat supply scenario. By applying future environmental policies, electricity can become a more environmentally friendly option than natural gas.


2021 ◽  
Vol 246 ◽  
pp. 14002
Author(s):  
Åsa Wahlström ◽  
Mari-Liis Maripuu

This study has analysed which options would be appropriate to use as additional requirements to the main requirement of primary energy number in the new Swedish building regulations. The starting point is to ensure that buildings are built with good qualitative properties in terms of the building envelope so that low energy use can be maintained throughout the life of the building despite changes in installation systems or the building’s occupancy. The additional requirements should aim to minimize energy losses, i.e., to ensure that the building's total energy demand is low. The following possible additional requirements have been examined: net energy demand, net energy demand for heating, heat power demand, heat loss rate and average heat transfer coefficient. In order to ensure that the additional requirements will work as desired and to explore possibilities with, and identify the consequences of, the various proposals, calculations have been made for four different categories of buildings: single-family houses, apartment buildings, schools and offices. The results show that the suggested option net energy demand will not contribute to any additional benefits in relation to primary energy number. The other options analysed have both advantages and disadvantages and it is difficult to find a single additional requirement that fulfils all the pre-set demands.


Energies ◽  
2019 ◽  
Vol 12 (8) ◽  
pp. 1571
Author(s):  
Cristian Sánchez ◽  
Lionel Bloch ◽  
Jordan Holweger ◽  
Christophe Ballif ◽  
Nicolas Wyrsch

Advanced control of heat pumps with thermal storage and photovoltaics has recently been promoted as a promising solution to help decarbonise the residential sector. Heat pumps and thermal storage offer a valuable flexibilisation mean to integrate stochastic renewable energy sources into the electricity grid. Heat pump energy conversion is nonlinear, leading to a challenging nonlinear optimisation problem. However, issues like global optimum uncertainty and the time-consuming methods of current nonlinear programming solvers draw researchers to linearise heat pump models that are then implemented in faster and globally convergent linear programming solvers. Nevertheless, these linearisations generate some inaccuracies, especially in the calculation of the heat pump’s coefficient of performance ( C O P ). In order to solve all of these issues, this paper presents a heuristic control algorithm (HCA) to provide a fast, accurate and near-optimal solution to the original nonlinear optimisation problem for a single-family house with a photovoltaic system, using real consumption data from a typical Swiss house. Results highlight that the HCA solves this optimisation problem up to 1000 times faster, yielding an operation that is up to 49% cheaper and self-consumption rates that are 5% greater than other nonlinear solvers. Comparing the performance of the HCA and the linear solver intlinprog, it is shown that the HCA provides more accurate heat pump control with an increase of up to 9% in system Operating Expense OPEX and a decrease of 8% in self-consumption values.


Sign in / Sign up

Export Citation Format

Share Document