scholarly journals Analysis of Cold Air Recirculation in the Evaporators of Large-Scale Air-Source Heat Pumps Using CFD Simulations

Fluids ◽  
2020 ◽  
Vol 5 (4) ◽  
pp. 186
Author(s):  
Brice Rogié ◽  
Jonas Kjær Jensen ◽  
Svenn Ole Kjøller Hansen ◽  
Wiebke Brix Markussen

The present study investigates cold air recirculation in the evaporators of large-scale air-source heat pumps. A case study considered a 5 MW air-source heat pump producing heat for district heating. The heat pump comprises 20 horizontal evaporators, where each evaporator is equipped with eight fans. The evaporators were implemented in a CFD model, where the influence of the outdoor wind direction on the recirculation was investigated. Firstly, the air recirculation was analysed with no surrounding obstacles. Secondly, the surrounding building and the real ground topology was included in the CFD model, to analyse their influence on the air recirculation. The results show that recirculation occurs for all wind directions, due to the turbulent behaviour of the flow around the evaporators. The results also show that the presence of a building intensifies the recirculation when it is placed directly upstream of the evaporators due to the presence of vortices in the wake of the building. On the other hand, a ground depression helps to reduce the recirculation by having additional energy dissipation due to the sudden change in the ground direction.

Energy ◽  
2019 ◽  
Vol 180 ◽  
pp. 918-933 ◽  
Author(s):  
Eftim Popovski ◽  
Ali Aydemir ◽  
Tobias Fleiter ◽  
Daniel Bellstädt ◽  
Richard Büchele ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2273
Author(s):  
Seung-Hoon Park ◽  
Yong-Sung Jang ◽  
Eui-Jong Kim

The earth provides a vast resource of groundwater from aquifers a few meters beneath the surface. Thus, buildings that use underground space must be equipped with dewatering wells to drain the permeated groundwater to the sewage pipelines to ensure the structural stability of the building. Although the inflowing groundwater temperatures and flow rates are stable enough for groundwater to be used as an energy source, 79% of the permeated groundwater is discarded through the sewers, generating significant sewerage expenses. This study introduced a novel heat exchanger module to utilize the permeated groundwater as an unused energy source using heat pumps, and the performance of the system was evaluated by TRNSYS simulations. First, the sizing of the unit heat exchanger module was proposed according to the mean inflow rate of the permeated groundwater. Second, the heat pump system was configured using multiple modules in the source-side loop. Finally, the performance of the proposed heat pump system was compared with that of a conventional air source heat pump using realistic load and temperature profiles. This preliminary study demonstrated interesting performance results, with a coefficient of performance for heating that was higher than that of a conventional heat pump system by 0.79. The results show the potential utilization of the systems for a construction project requiring large-scale underground spaces, where abundant groundwater is available.


Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 954 ◽  
Author(s):  
Hanne Kauko ◽  
Daniel Rohde ◽  
Armin Hafner

District heating enables an economical use of energy sources that would otherwise be wasted to cover the heating demands of buildings in urban areas. For efficient utilization of local waste heat and renewable heat sources, low distribution temperatures are of crucial importance. This study evaluates a local heating network being planned for a new building area in Trondheim, Norway, with waste heat available from a nearby ice skating rink. Two alternative supply temperature levels have been evaluated with dynamic simulations: low temperature (40 °C), with direct utilization of waste heat and decentralized domestic hot water (DHW) production using heat pumps; and medium temperature (70 °C), applying a centralized heat pump to lift the temperature of the waste heat. The local network will be connected to the primary district heating network to cover the remaining heat demand. The simulation results show that with a medium temperature supply, the peak power demand is up to three times higher than with a low temperature supply. This results from the fact that the centralized heat pump lifts the temperature for the entire network, including space and DHW heating demands. With a low temperature supply, heat pumps are applied only for DHW production, which enables a low and even electricity demand. On the other hand, with a low temperature supply, the district heating demand is high in the wintertime, in particular if the waste heat temperature is low. The choice of a suitable supply temperature level for a local heating network is hence strongly dependent on the temperature of the available waste heat, but also on the costs and emissions related to the production of district heating and electricity in the different seasons.


2013 ◽  
Vol 805-806 ◽  
pp. 645-648
Author(s):  
Wei Xiu Shi ◽  
Li Sheng Pan

Under the situation of energy crisis, air source heat pumps are paid more attention recently. In order to save energy, the feasibility and performance of air source heat pump are studied by experiment, and variation laws of exhaust temperature, evaporator outlet temperature and outlet presser of compressor were analyzed in this paper. Air source heat pump apparatus were set up and the experiment was during 10°C, 20°C, 30°C and 40°C. The results were as follows: exhaust temperature of compressor increases gradually with the increase of tank temperature, but the temperature difference between exhaust temperature of compressor and tank temperature becomes little; temperature difference in evaporator decreases; Compressor outlet pressure increases obviously.


Energies ◽  
2022 ◽  
Vol 15 (2) ◽  
pp. 584
Author(s):  
Chiara Magni ◽  
Sylvain Quoilin ◽  
Alessia Arteconi

Flexibility is crucial to enable the penetration of high shares of renewables in the power system while ensuring the security and affordability of the electricity dispatch. In this regard, heat–electricity sector coupling technologies are considered a promising solution for the integration of flexible devices such as thermal storage units and heat pumps. The deployment of these devices would also enable the decarbonization of the heating sector, responsible for around half of the energy consumption in the EU, of which 75% is currently supplied by fossil fuels. This paper investigates in which measure the diffusion of district heating (DH) coupled with thermal energy storage (TES) units can contribute to the overall system flexibility and to the provision of operating reserves for energy systems with high renewable penetration. The deployment of two different DH supply technologies, namely combined heat and power units (CHP) and large-scale heat pumps (P2HT), is modeled and compared in terms of performance. The case study analyzed is the future Italian energy system, which is simulated through the unit commitment and optimal dispatch model Dispa-SET. Results show that DH coupled with heat pumps and CHP units could enable both costs and emissions related to the heat–electricity sector to be reduced by up to 50%. DH systems also proved to be a promising solution to grant the flexibility and resilience of power systems with high shares of renewables by significantly reducing the curtailment of renewables and cost-optimally providing up to 15% of the total upward reserve requirements.


Energies ◽  
2019 ◽  
Vol 12 (7) ◽  
pp. 1274 ◽  
Author(s):  
Arif Widiatmojo ◽  
Sasimook Chokchai ◽  
Isao Takashima ◽  
Yohei Uchida ◽  
Kasumi Yasukawa ◽  
...  

The cooling of spaces in tropical regions, such as Southeast Asia, consumes a lot of energy. Additionally, rapid population and economic growth are resulting in an increasing demand for space cooling. The ground-source heat pump has been proven a reliable, cost-effective, safe, and environmentally-friendly alternative for cooling and heating spaces in various countries. In tropical countries, the presumption that the ground-source heat pump may not provide better thermal performance than the normal air-source heat pump arises because the difference between ground and atmospheric temperatures is essentially low. This paper reports the potential use of a ground-source heat pump with horizontal heat exchangers in a tropical country—Thailand. Daily operational data of two ground-source heat pumps and an air-source heat pump during a two-month operation are analyzed and compared. Life cycle cost analysis and CO2 emission estimation are adopted to evaluate the economic value of ground-source heat pump investment and potential CO2 reduction through the use of ground-source heat pumps, in comparison with the case for air-source heat pumps. It was found that the ground-source heat pumps consume 17.1% and 18.4% less electricity than the air-source heat pump during this period. Local production of heat pumps and heat exchangers, as well as rapid regional economic growth, can be positive factors for future ground-source heat pump application, not only in Thailand but also southeast Asian countries.


2020 ◽  
Vol 103 (2) ◽  
pp. 003685042092168
Author(s):  
Weisong Zhou ◽  
Peng Pei ◽  
Ruiyong Mao ◽  
Haibin Qian ◽  
Yanbing Hu ◽  
...  

In order to take advantage of different forms of heat pumps and to mitigate thermal imbalance underground caused by long-term operation of ground source heat pumps, hybrid ground source heat pump systems have received an increasing attention. In this research, based on the fact that abundant groundwater resources are commonly available in karst regions, a new strategy is introduced for selecting and determining hybrid ground source heat pump capacity. Five scenarios of hybrid ground source heat pump system coupling groundwater source heat pumps with other supplementary heat pumps are proposed in this article to provide appropriate options to eliminate heat buildup under different hydrogeologic conditions. Methodologies for sizing and selection are established. Then, a case study of techno-economic analysis was performed for a project in the karst region in South China. The results showed that these scenarios can effectively mitigate heat buildup, and under the hydrogeologic condition in the case study. Compared to the solo ground-coupled heat pump solution, the optimal solution (Solution 4 in this study) can reduce the annual costs by 16.10% and reduce the capital investment by 60%. Methodologies developed in this study are beneficial for selecting appropriate approaches to mitigate heat buildup and enhance competitiveness of ground source heat pumps.


Author(s):  
Anna Volkova ◽  
Vladislav Mashatin ◽  
Aleksander Hlebnikov ◽  
Andres Siirde

Abstract The purpose of this paper is to offer a methodology for the evaluation of large district heating networks. The methodology includes an analysis of heat generation and distribution based on the models created in the TERMIS and EnergyPro software Data from the large-scale Tallinn district heating system was used for the approbation of the proposed methodology as a basis of the case study. The effective operation of the district heating system, both at the stage of heat generation and heat distribution, can reduce the cost of heat supplied to the consumers. It can become an important factor for increasing the number of district heating consumers and demand for the heat load, which in turn will allow installing new cogeneration plants, using renewable energy sources and heat pump technologies


Energy ◽  
2018 ◽  
Vol 155 ◽  
pp. 921-929 ◽  
Author(s):  
Poul Alberg Østergaard ◽  
Anders N. Andersen

Sign in / Sign up

Export Citation Format

Share Document