scholarly journals Study of Corrosion Resistance Properties of Heat Exchanger Metals in Two Different Geothermal Environments

Geosciences ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 498
Author(s):  
Svava Davíðsdóttir ◽  
Baldur Geir Gunnarsson ◽  
Kjartan Björgvin Kristjánsson ◽  
Béatrice A. Ledésert ◽  
Dagur Ingi Ólafsson

Geothermal fluids harnessed for electricity production are generally corrosive because of their interaction with the underground. To ensure the longevity and sustainability of geothermal Organic Rankine Cycle (ORC) powerplants, the choice of heat exchanger material is essential. The performance of heat exchangers is affected by corrosion and scaling due to the geothermal fluids, causing regular cleaning, part replacement, and in the worst cases, extensive repair work. The properties of geothermal fluids vary between geothermal settings and even within geothermal sites. Differences in exposure conditions require different material selection considerations, where factors such as cost, and material efficiency are important to consider. This work studies in-situ geothermal exposure testing of four metals at two geothermal locations, in different geological settings. Four corrosion-resistant materials were exposed for one month at Reykjanes powerplant in Iceland and four months at Chaunoy oil field in France as material candidates for heat exchangers. The tested alloys were analysed for corrosion with macro- and microscopic techniques using optical and electron microscopes, which give an indication of the different frequencies of repairs and replacement. Inconel 625 showed no effects at Reykjanes and cracks at Chaunoy. The others (316L, 254SMO, and titanium grade 2) showed either corrosion or erosion traces at both sites.

Energies ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 2737
Author(s):  
Francesca Ceglia ◽  
Adriano Macaluso ◽  
Elisa Marrasso ◽  
Maurizio Sasso ◽  
Laura Vanoli

Improvements in using geothermal sources can be attained through the installation of power plants taking advantage of low and medium enthalpy available in poorly exploited geothermal sites. Geothermal fluids at medium and low temperature could be considered to feed binary cycle power plants using organic fluids for electricity “production” or in cogeneration configuration. The improvement in the use of geothermal aquifers at low-medium enthalpy in small deep sites favours the reduction of drilling well costs, and in addition, it allows the exploitation of local resources in the energy districts. The heat exchanger evaporator enables the thermal heat exchange between the working fluid (which is commonly an organic fluid for an Organic Rankine Cycle) and the geothermal fluid (supplied by the aquifer). Thus, it has to be realised taking into account the thermodynamic proprieties and chemical composition of the geothermal field. The geothermal fluid is typically very aggressive, and it leads to the corrosion of steel traditionally used in the heat exchangers. This paper analyses the possibility of using plastic material in the constructions of the evaporator installed in an Organic Rankine Cycle plant in order to overcome the problems of corrosion and the increase of heat exchanger thermal resistance due to the fouling effect. A comparison among heat exchangers made of commonly used materials, such as carbon, steel, and titanium, with alternative polymeric materials has been carried out. This analysis has been built in a mathematical approach using the correlation referred to in the literature about heat transfer in single-phase and two-phase fluids in a tube and/or in the shell side. The outcomes provide the heat transfer area for the shell and tube heat exchanger with a fixed thermal power size. The results have demonstrated that the plastic evaporator shows an increase of 47.0% of the heat transfer area but an economic installation cost saving of 48.0% over the titanium evaporator.


Energies ◽  
2019 ◽  
Vol 12 (9) ◽  
pp. 1783 ◽  
Author(s):  
Jesper Graa Andreasen ◽  
Martin Ryhl Kærn ◽  
Fredrik Haglind

In this paper, we present an assessment of methods for estimating and comparing the thermodynamic performance of working fluids for organic Rankine cycle power systems. The analysis focused on how the estimated net power outputs of zeotropic mixtures compared to pure fluids are affected by the method used for specifying the performance of the heat exchangers. Four different methods were included in the assessment, which assumed that the organic Rankine cycle systems were characterized by the same values of: (1) the minimum pinch point temperature difference of the heat exchangers; (2) the mean temperature difference of the heat exchangers; (3) the heat exchanger thermal capacity ( U ¯ A ); or (4) the heat exchanger surface area for all the considered working fluids. The second and third methods took into account the temperature difference throughout the heat transfer process, and provided the insight that the advantages of mixtures are more pronounced when large heat exchangers are economically feasible to use. The first method was incapable of this, and deemed to result in optimistic estimations of the benefits of using zeotropic mixtures, while the second and third method were deemed to result in conservative estimations. The fourth method provided the additional benefit of accounting for the degradation of heat transfer performance of zeotropic mixtures. In a net power output based performance ranking of 30 working fluids, the first method estimates that the increase in the net power output of zeotropic mixtures compared to their best pure fluid components is up to 13.6%. On the other hand, the third method estimates that the increase in net power output is only up to 2.56% for zeotropic mixtures compared to their best pure fluid components.


Energies ◽  
2021 ◽  
Vol 14 (21) ◽  
pp. 6994
Author(s):  
Alberto Carotenuto ◽  
Francesca Ceglia ◽  
Elisa Marrasso ◽  
Maurizio Sasso ◽  
Laura Vanoli

The highest economic costs of a geothermal plant are basically related to well drilling and heat exchanger maintenance cost due to the chemical aggressiveness of geothermal fluid. The possibility to reduce these costs represents an opportunity to push toward geothermal plants development. Such challenges are even more important in the sites with a low-medium temperature geothermal fluids (90–120 °C) availability, where the use of these fluids for direct thermal uses can be very advantageous. For this reason, in this study, a direct geothermal heating system for a building will be investigated by considering a plastic plate heat exchanger. The choice of a polymeric heat exchanger for this application is upheld by its lower purchase cost and its higher fouling resistance than the common metal heat exchangers, overcoming the economic issues related to conventional geothermal plant. Thus, the plastic plate heat exchanger was, firstly, geometrical and thermodynamical modeled and, after, exergoeconomic optimized. In particular, an exergoeconomic analysis was assessed on the heat exchanger system by using a MATLAB and REFPROP environment, that allows for determination of the exergoeconomic costs of the geothermal fluid extraction, the heat exchanger, and the heating production. A sensitivity analysis was performed to evaluate the effect of main design variable (number of plates/channels) and thermodynamic variable (inlet temperature of geothermal fluid) on yearly exergoeconomic product cost. Then, the proposed methodology was applied to a case study in South of Italy, where a low-medium enthalpy geothermal potential exists. The plate-heat exchanger was used to meet the space heating requests of a single building by the exploitation of low-medium temperature geothermal fluids availability in the selected area. The results show that the inlet temperature of geothermal fluid influences the exergoeconomic cost more than the geometrical parameter. The variation of the exergoeconomic cost of heat exchanger with the inlet geothermal fluid temperature is higher than the change of the exergoeconomic costs associated to wells drilling and pumping with respect to the same variable. This is due the fact that, in the selected zone of South of Italy, it is possible to find geothermal fluid in the temperature range of 90–120 °C, at shallow depth. The product exergoeconomic cost is the lowest when the temperature is higher than 105 °C; thus, the smallest heat exchange area is required. The exergoeconomic optimization determines an optimum solution with a total product cost of 922 €/y for a temperature of geothermal fluid equal to 117 °C and with a number of plates equal to 15.


Author(s):  
H. R. Salimi Jazi ◽  
J. Mostaghimi ◽  
S. Chandra ◽  
L. Pershin ◽  
T. Coyle

Open pore metal foams make efficient heat exchanger because of their high thermal conductivity and low permeability. This study describes a novel method of using wire-arc spraying to deposit Inconel 625 skins on the surface of sheets of 10 and 20 pores per linear inch nickel foam. The skins adhere strongly to the foam struts, giving high heat-transfer rates. Tests were done to determine the hydraulic and thermal characteristics of the heat exchangers and correlations developed to calculate Fanning friction factor and Nusselt number as a function of Reynolds number for airflow through the foam. Measured heat-transfer coefficients for the foam heat exchangers are greater than those of straight flow channels at the same flow rate. A ceramic thermal barrier coating was deposited on one face of the heat exchanger using plasma spraying. The coating and heat exchanger survived prolonged exposure to the flame of a methane-air burner.


Geosciences ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 271
Author(s):  
Béatrice A. Ledésert ◽  
Ronan L. Hébert ◽  
Justine Mouchot ◽  
Clio Bosia ◽  
Guillaume Ravier ◽  
...  

The Soultz-Sous-Forêts geothermal site (France) operates three deep wells for electricity production. During operation, scales precipitate within the surface installation as (Ba, Sr) sulfate and (Pb, As, Sb) sulfide types. Scales have an impact on lowering energy production and inducing specific waste management issues. Thus scaling needs to be reduced for which a thorough characterization of the scales has to be performed. The geothermal brine is produced at 160 °C and reinjected at 70 °C during normal operation. In the frame of the H2020 MEET project, a small heat exchanger was tested in order to allow higher energy production, by reinjecting the geothermal fluid at 40 °C. Samples of scales were analyzed by XRD and SEM-EDS, highlighting that mostly galena precipitates and shows various crystal shapes. These shapes can be related to the turbulence of the flow and the speed of crystal growth. Where the flow is turbulent (entrance, water box, exit), crystals grow quickly and mainly show dendritic shape. In the tubes, where the flow is laminar, crystals grow more slowly and some of them are characterized by well-developed faces leading to cubes and derived shapes. The major consequence of the temperature decrease is the increased scaling phenomenon.


2017 ◽  
Vol 139 (2) ◽  
Author(s):  
Jiuyi Liu ◽  
Caifu Qian ◽  
Huifang Li

Thermal stress is an important factor influencing the strength of a heat exchanger tubesheet. Some studies have indicated that, even in floating-head or U-tube heat exchangers, the thermal stress at the tubesheet is significant in magnitude. For exploring the value, distribution, and the influence factors of the thermal stress at the tubesheet of these kind heat exchangers, a tubesheet and triangle arranged tubes with the tube diameter of 25 mm were numerically analyzed. Specifically, the thermal stress at the tubesheet center is concentrated and analyzed with changing different parameters of the tubesheet, such as the temperature difference between tube-side and shell-side fluids, tubesheet diameter, thickness, and the tube-hole area ratio. It is found that the thermal stress of the tubesheet of floating-head or U-tube heat exchanger was comparable in magnitude with that produced by pressures, and the distribution of the thermal stress depends on the tube-hole area and the temperature inside the tubes. The thermal stress at the center of the tubesheet surface is high when tube-hole area ratio is very low. And with increasing the tube-hole area ratio, the stress first decreases rapidly and then increases linearly. A formula was numerically fitted for calculating the thermal stress at the tubesheet surface center which may be useful for the strength design of the tubesheet of floating-head or U-tube heat exchangers when considering the thermal stress. Numerical tests show that the fitted formula can meet the accuracy requirements for engineering applications.


2012 ◽  
Vol 629 ◽  
pp. 699-703
Author(s):  
Chun Sheng Guo ◽  
Wen Jing Du ◽  
Lin Cheng

The entransy loss minimization approach for the heat exchanger optimization design was established by Guo Z Y; the study based Guo Z Y’s works, found relationship between the entransy loss uniformity and the heat exchanger performance and the expression of the local entransy loss rate for heat convection was derived, numerical results of the heat transfer in a chevron plate heat exchanger and helix baffle heat exchanger show that the larger entransy loss uniformity factor appear in about Re=2000 and the entransy loss uniformity factor of chevron plate heat exchanges higher than helix baffle one.


Author(s):  
H. Zabiri ◽  
V. R. Radhakrishnan ◽  
M. Ramasamy ◽  
N. M. Ramli ◽  
V. Do Thanh ◽  
...  

The Crude Preheat Train (CPT) is a set of large heat exchangers which recover the waste heat from product streams back to preheat the crude oil. The overall heat transfer coefficient in these heat exchangers may be significantly reduced due to fouling. One of the major impacts of fouling in CPT operation is the reduced heat transfer efficiency. The objective of this paper is to develop a predictive model using statistical methods which can a priori predict the rate of the fouling and the decrease in heat transfer efficiency in a heat exchanger in a crude preheat train. This predictive model will then be integrated into a preventive maintenance diagnostic tool to plan the cleaning of the heat exchanger to remove the fouling and bring back the heat exchanger efficiency to their peak values. The fouling model was developed using historical plant operating data and is based on Neural Network. Results show that the predictive model is able to predict the shell and tube outlet temperatures with excellent accuracy, where the Root Mean Square Error (RMSE) obtained is less than 1%, correlation coefficient R2 of approximately 0.98 and Correct Directional Change (CDC) values of more than 90%. A preliminary case study shows promising indication that the predictive model may be integrated into a preventive maintenance scheduling for the heat exchanger cleaning.


Sign in / Sign up

Export Citation Format

Share Document