scholarly journals Ultrasound Imaging Evaluation of Textural Features in Athletes with Soleus Pathology—A Novel Case-Control Study

Author(s):  
Blanca De-la-Cruz-Torres ◽  
Emmanuel Navarro-Flores ◽  
Daniel López-López ◽  
Carlos Romero-Morales

Background: the aim of this study was to compare the echotexture of patients with soleus muscle injury and age matched controls. Methods: a sample of 62 athletes was recruited at the private clinic and was divided in two group: a healthy group (n = 31) and a soleus pathology group whose athletes had soleus muscle injury, located in the central tendon (n = 31). The muscle thickness (MTh), echointensity (EI) and echovariation (EV) were analyzed. An intra-rater reliability test (Intraclass Correlation Coefficient-ICC) was performed in order to analyze the reliability of the values of the measurements. Results: Sociodemographic variables did not show statistically significant differences (p > 0.05). Ultrasound imaging measurements who reported statistically significant differences were EI (p = 0.001) and standard deviation (SD) (p = 0.001). MTh and EV variables did not show statistically significant differences (p = 0.381 and p = 0.364, respectively). Moreover, reliability values for the MTh (ICC = 0.911), EI (ICC = 0.982), SD (ICC = 0.955) and EV (ICC = 0.963). Based on these results the intra-rater reliability was considered excellent. Conclusion: Athletes with a central tendon injury of soleus muscle showed a lower EI when they were compared to healthy athletes. The echogenicity showed by the quantitative ultrasound imaging measurement may be a more objective parameter for the diagnosis and follow-up the soleus muscle injuries.

2016 ◽  
Vol 20 (6) ◽  
pp. 535-542 ◽  
Author(s):  
Amilton Vieira ◽  
Angelina F. Siqueira ◽  
João B. Ferreira-Junior ◽  
Paulo Pereira ◽  
Dale Wagner ◽  
...  

Healthcare ◽  
2020 ◽  
Vol 8 (4) ◽  
pp. 555
Author(s):  
Carlos Romero-Morales ◽  
Cesar Calvo-Lobo ◽  
Emmanuel Navarro-Flores ◽  
Victoria Mazoteras-Pardo ◽  
Paula García-Bermejo ◽  
...  

Objective: M-mode ultrasound imaging (US) reflects the motion of connective tissue within muscles. The objectives of this study were to evaluate inter-rater and intra-rater reliability of soleus muscle measurements between examiners with different levels of US experience in asymptomatic subjects and to investigate the level of soleus muscle isometric activity in two positions (knee extended and knee flexed at 30°). Methods: Thirty volunteers without a history of ankle pain were evaluated with US examinations of the soleus muscle. Each muscle was scanned independently by two evaluators. Muscle at rest thickness, maximal isometric contraction thickness, time and velocity measures were detailed and blinded to the other examiner. Results: Intra- and inter-rater reliability at rest, in maximal isometric contraction thickness, contraction time and contraction velocity measures for both positions (extended and flexed knee) were reported from good to excellent for all outcome measurements. The position with the knee extended reported a statistically significant increase in thickness after motion showing 1.33 ± 0.27 mm for measurements at rest thickness with knee extended versus 1.50 ± 0.29 mm for measurements at end thickness with the knee in flexed position (p = 0.001), as well as 1.31 ± 0.23 mm for rest thickness with the knee in flexed position measurements with respect to 1.34 ± 0.24 mm for maximal isometric contraction thickness with extended knee measurements (p = 0.058). Conclusions: This study found that intra- and inter-examiner reliability of M-mode ultrasound imaging of the soleus muscle was excellent in asymptomatic subjects and the soleus muscle activity was different between the position with the knee extended and the position with the knee flexed.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Fernando Santiago-Nuño ◽  
Patricia Palomo-López ◽  
Ricardo Becerro-de-Bengoa-Vallejo ◽  
César Calvo-Lobo ◽  
Marta Elena Losa-Iglesias ◽  
...  

Abstract The purpose was to evaluate intra and inter-rater reliability, repeatability and absolute accuracy between ultrasound imaging (US) and caliper measures to determine Spring ligament (SL) dimensions in cadavers. SLs were identified from 62 human feet from formaldehyde-embalmed cadavers. Intra and inter-observer reliability, repeatability and absolute accuracy of SL width, thickness and length between US and caliper measurements were determined at intra and inter-session by intraclass correlation coefficients, Pearson´s correlation coefficients, Student t tests, standard errors of measurement, minimum detectable changes, values of normality, 95% limits of agreement, and Bland-Altman plots. Excellent inter-session and inter-rater reliability, adequate absolute accuracy, almost perfect agreement and strong correlations were shown for caliper, US and their comparison for all SL dimensions. US measurements presented higher absolute accuracy than caliper measures for SL length and thickness dimensions, while caliper displayed greater absolute accuracy for SL width dimensions. Good repeatability (P > 0.05) was shown for all SL dimensions by US, caliper and their comparison, except for SL width dimension measured with US (P = 0.019). Both US and caliper could be recommended for all SL dimensions evaluation due to their excellent reliability and absolute accuracy in cadavers, although width dimensions should be considered with caution due to US repeatability differences.


2019 ◽  
Vol 12 (1) ◽  
Author(s):  
Prue Molyneux ◽  
Richard F. Ellis ◽  
Matthew Carroll

Abstract Background Alteration in the strain properties of the Achilles tendon may lead to adaptations such as pathological stiffening. Stiff tendons have reduced adaptive ability, which may increase the risk for developing tendinopathy. Strain can be measured using musculoskeletal ultrasound imaging. A two-probe ultrasound procedure may reduce the measurement error associated with a one-probe procedure. However, the reliability of the two-probe procedure has not been established. This study aimed to determine the within-session intra- and inter-rater reliability and between-session reliability of a two-probe ultrasound procedure to measure Achilles tendon strain. Methods Participants were 29 healthy individuals (19 females, 10 males; mean age 33.6 years). Achilles tendon images were acquired with a two-probe ultrasound procedure as the ankle moved through a standardised range of motion (20° plantarflexion to 10° dorsiflexion). Both probes were positioned longitudinally, one over the musculotendinous junction and the second over the calcaneal insertion of the Achilles tendon. Repeat measurements were taken for all participants at the initial study visit, and for 10 participants in a second measurement session 4 weeks later. Strain measures were calculated from pre-captured images using Motion Analysis 2014v1 software by two independent raters. Within-session intra- and inter-rater reliability and between-session intra-rater reliability were calculated using intraclass correlation coefficients (ICC) with 95% confidence intervals. The standard error of measurement was also calculated. Results The two-probe procedure to measure Achilles tendon strain showed excellent within-session intra-rater (ICC = 0.84, p < 0.001) and inter-rater reliability (ICC = 0.88, p = 0.003), but poor between-session intra-rater reliability (ICC = 0.18, p = 0.397). Conclusion The two-probe procedure to measure Achilles tendon strain is reliable for repeated measurements on the same day. However, measurement error increased when strain was measured on different days, which may be attributable to a combination of examiner error and participant factors. Measurement of Achilles tendon strain offers an additional tool for evaluating the tendon’s mechanical characteristics. The ability to reliably quantify strain may allow clinicians to identify those at risk for Achilles tendinopathy and formulate more effective management plans.


2021 ◽  
Vol 7 (2) ◽  
pp. e001010
Author(s):  
Ricky Shamji ◽  
Steven L J James ◽  
Rajesh Botchu ◽  
Kent A Khurniawan ◽  
Gurjit Bhogal ◽  
...  

BackgroundThe relationship between hamstring muscle injuries (HMIs) that involve the intramuscular tendon and prolonged recovery time and increased reinjury rate remains unclear in elite footballers.ObjectiveTo determine the association of time to return to full training (TRFT) and reinjury of HMIs using the British Athletic Muscle Injury Classification (BAMIC) and specific anatomical injury location in elite-level football players.MethodsThe electronic medical records of all players at an English Premier League club were reviewed over eight consecutive seasons. All players who sustained an acute HMI were included. Two experienced musculoskeletal radiologists independently graded each muscle using the BAMIC, categorised each injury location area (proximal vs middle vs distal third and proximal vs distal tendon) and reported second muscle involvement. TRFT and reinjury were recorded.ResultsOut of 61 HMIs, the intramuscular tendon (BAMIC ‘c’) was involved in 13 (21.3%). HMI involving the intramuscular tendon (‘c’) had a mean rank TRFT of 36 days compared with 24 days without involvement (p=0.013). There were 10 (16.4%) reinjuries with a significant difference of 38.5% reinjury rate in the group with intramuscular tendon injury (‘c’) and 12.5% in the group without (p=0.031). TRFT and reinjury involving a second muscle was statistically significantly higher than without. Most of the HMIs to the biceps femoris with reinjury (5 out of 9) were in the distal third section related to the distal tendon site involving both the long and short head.ConclusionTRFT in HMI involving the intramuscular tendon (‘c’) of the Biceps femoris is significantly longer with significantly higher reinjury rate compared with injuries without, in elite football players. The finding that most reinjures of the biceps femoris occurring in the distal third muscle at the distal tendon site, involving both the long and short head, merits further investigation.


2021 ◽  
pp. 1-10
Author(s):  
Ryo Miyachi ◽  
Nana Koike ◽  
Suzu Kodama ◽  
Junya Miyazaki

BACKGROUND: Although trunk muscles are involved in many important functions, evaluating trunk muscle strength is not an easy task. If trunk muscle mass and thickness could be used as indicators of trunk muscle strength, the burden of measurement would be reduced, but the relationship between trunk muscle strength and trunk muscle mass and thickness has not been clarified. OBJECTIVE: The purpose of this study was to clarify the relationship between trunk muscle strength and trunk muscle mass by bioelectrical impedance analysis and trunk muscle thickness by ultrasound imaging in healthy adults. METHODS: One hundred and twenty-one healthy university students were included in this study. Trunk flexion/extension muscle strength and trunk muscle mass by bioelectrical impedance analysis, and trunk muscle thickness by ultrasound imaging were measured. RESULTS: Both trunk flexion strength and trunk extension strength were significantly correlated with trunk muscle mass and oblique and rectus abdominis muscle thickness. Multiple regression analysis showed that trunk extension muscle strength had an independent relationship with trunk muscle mass. CONCLUSIONS: This study demonstrated that trunk muscle mass or trunk muscle thickness can be used as an alternative means for evaluating trunk muscle strength, making the evaluation of trunk muscles less burdensome.


Author(s):  
Aida Carballo-Fazanes ◽  
Ezequiel Rey ◽  
Nadia C. Valentini ◽  
José E. Rodríguez-Fernández ◽  
Cristina Varela-Casal ◽  
...  

The Test of Gross Motor Development (TGMD) is one of the most common tools for assessing the fundamental movement skills (FMS) in children between 3 and 10 years. This study aimed to examine the intra-rater and inter-rater reliability of the TGMD—3rd Edition (TGMD-3) between expert and novice raters using live and video assessment. Five raters [2 experts and 3 novices (one of them BSc in Physical Education and Sport Science)] assessed and scored the performance of the TGMD-3 of 25 healthy children [Female: 60%; mean (standard deviation) age 9.16 (1.31)]. Schoolchildren were attending at one public elementary school during the academic year 2019–2020 from Santiago de Compostela (Spain). Raters scored each children performance through two viewing moods (live and slow-motion). The ICC (Intraclass Correlation Coefficient) was used to determine the agreement between raters. Our results showed moderate-to-excellent intra-rater reliability for overall score and locomotor and ball skills subscales; moderate-to-good inter-rater reliability for overall and ball skills; and poor-to-good for locomotor subscale. Higher intra-rater reliability was achieved by the expert raters and novice rater with physical education background compared to novice raters. However, the inter-rater reliability was more variable in all the raters regardless of their experience or background. No significant differences in reliability were found when comparing live and video assessments. For clinical practice, it would be recommended that raters reach an agreement before the assessment to avoid subjective interpretations that might distort the results.


Author(s):  
Henriëtte A. W. Meijer ◽  
Maurits Graafland ◽  
Miryam C. Obdeijn ◽  
Marlies P. Schijven ◽  
J. Carel Goslings

Abstract Purpose To determine the validity of wrist range of motion (ROM) measurements by the wearable-controlled ReValidate! wrist-rehabilitation game, which simultaneously acts as a digital goniometer. Furthermore, to establish the reliability of the game by contrasting ROM measurements to those found by medical experts using a universal goniometer. Methods As the universal goniometer is considered the reference standard, inter-rater reliability between surgeons was first determined. Internal validity of the game ROM measurements was determined in a test–retest setting with healthy volunteers. The reliability of the game was tested in 34 patients with a restricted range of motion, in whom the ROM was measured by experts as well as digitally. Intraclass-correlation coefficients (ICCs) were determined and outcomes were analyzed using Bland–Altman plots. Results Inter-rater reliability between experts using a universal goniometer was poor, with ICCs of 0.002, 0.160 and 0.520. Internal validity testing of the game found ICCs of − 0.693, 0.376 and 0.863, thus ranging from poor to good. Reliability testing of the game compared to medical expert measurements, found that mean differences were small for the flexion–extension arc and the radial deviation-ulnar deviation arc. Conclusion The ReValidate! game is a reliable home-monitoring device digitally measuring ROM in the wrist. Interestingly, the test–retest reliability of the serious game was found to be considerably higher than the inter-rater reliability of the reference standard, being healthcare professionals using a universal goniometer. Trial registration number (internal hospital registration only) MEC-AMC W17_003 #17.015.


2021 ◽  
Vol 11 (9) ◽  
pp. 3947
Author(s):  
Marco Farronato ◽  
Gianluca M. Tartaglia ◽  
Cinzia Maspero ◽  
Luigi M. Gallo ◽  
Vera Colombo

Clinical use of portable optical tracking system in dentistry could improve the analysis of mandibular movements for diagnostic and therapeutic purposes. A new workflow for the acquisition of mandibular kinematics was developed. Reproducibility of measurements was tested in vitro and intra- and inter-rater repeatability were assessed in vivo in healthy volunteers. Prescribed repeated movements (n = 10) in three perpendicular directions of the tracking-device coordinate system were performed. Measurement error and coefficient of variation (CV) among repetitions were determined. Mandibular kinematics of maximum opening, left and right laterality, protrusion and retrusion of five healthy subjects were recorded in separate sessions by three different operators. Obtained records were blindly examined by three observers. Intraclass correlation coefficient (ICC) was calculated to estimate inter-rater and intra-rater reliability. Maximum in vitro measurement error was 0.54 mm and CV = 0.02. Overall, excellent intra-rater reliability (ICC > 0.90) for each variable, general excellent intra-rater reliability (ICC = 1.00) for all variables, and good reliability (ICC > 0.75) for inter-rater tests were obtained. A lower score was obtained for retrusion with “moderate reliability” (ICC = 0.557) in the inter-rater tests. Excellent repeatability and reliability in optical tracking of primary movements were observed using the tested portable tracking device and the developed workflow.


2021 ◽  
Author(s):  
Yoon-Soo Seo ◽  
Ki-Hun Jo ◽  
Jun-Sang CHA ◽  
Joo-Yeon Kim ◽  
Jae-Hwan Kwon

Abstract Background: This study investigates and compare the reliability and reproducibility of two facial anthropometric methods about external nasal angles, 3D imaging and conventional 2D photography. Methods: 2D photograph images and 3D images about external nose of 30 volunteers were taken using digital camera and Morpheus 3D scanner. To evaluate intra-rater reliability, each images were taken over two different days for each subject by the same researcher. To evaluate inter-rater reliability, another researcher took each images for each subject on the first day. The reliability of each method for measuring 4 external nasal angle is obtained using intraclass correlation coefficient (ICC) and compared.Results: Inter-rater and intra-rater reliability of both 3D imaging and 2D photography had excellent agreement in all 4 nasal angles. In the nasofacial angular parameter, Inter-rater ICC, 2D photography was significantly higher than 3D imaging. Result of intra-rater ICC also showed both 3D imaging and 2D photography had good reliability in all 4 nasal angles. Similar to those of inter-rater ICC, nasofacial angular parameter showed statistically significant differences between 3D imaging and 2D photography.Conclusion: In terms of reliability, both 2D and 3D showed appropriate anthropometric results and considering its own advantage, each methods can be used complementarily.