scholarly journals A Mobile Acquisition System and a Method for Hips Sway Fluency Assessment

Information ◽  
2018 ◽  
Vol 9 (12) ◽  
pp. 321 ◽  
Author(s):  
Andrea Civita ◽  
Simone Fiori ◽  
Giuseppe Romani

The present contribution focuses on the estimation of the Cartesian kinematic jerk of the hips’ orientation during a full three-dimensional movement in the context of enabling eHealth applications of advanced mathematical signal analysis. The kinematic jerk index is estimated on the basis of gyroscopic signals acquired offline through a smartphone. A specific free mobile application is used to acquire the gyroscopic signals and to transmit them to a personal computer through a wireless network. The personal computer elaborates the acquired data and returns the kinematic jerk index associated with a motor task. A comparison of the kinematic jerk index value on a number of data sets confirms that such index can be used to evaluate the fluency of hips orientation during motion. The present research confirms that the proposed gyroscopic data acquisition/processing setup constitutes an inexpensive and portable solution to motion fluency analysis. The proposed data-acquisition and data-processing setup may serve as a supporting eHealth technology in clinical bio-mechanics as well as in sports science.

2020 ◽  
Vol 17 (1) ◽  
pp. 172988141989564
Author(s):  
Aldo Aragón-Martínez ◽  
Manuel Arias-Montiel ◽  
Esther Lugo-González ◽  
Ricardo Tapia-Herrera

In this work, the design, manufacturing, instrumentation, and application of a two-finger exoskeleton with force feedback are presented. The exoskeleton is based on remote center of motion mechanisms in order to avoid mechanical interference with the user’s fingers and is manufactured by three-dimensional printing. The developed exoskeleton is applied in a mobile robot teleoperation by mapping the finger movements in forward and turning commands for the robot. The presence of obstacles detected by the robot is sensed by the user by means of a feedback force. The problem of simultaneously communicating a data acquisition card and the robot hardware by MATLAB ® Simulink® was solved by using an external Wi-Fi module. The result is a lightweight exoskeleton which is able to communicate bidirectionally with a mobile robot by a personal computer for teleoperation tasks. The success of the system implementation is proven by a set of experiments presented in the final part of the article.


Author(s):  
Mark Ellisman ◽  
Maryann Martone ◽  
Gabriel Soto ◽  
Eleizer Masliah ◽  
David Hessler ◽  
...  

Structurally-oriented biologists examine cells, tissues, organelles and macromolecules in order to gain insight into cellular and molecular physiology by relating structure to function. The understanding of these structures can be greatly enhanced by the use of techniques for the visualization and quantitative analysis of three-dimensional structure. Three projects from current research activities will be presented in order to illustrate both the present capabilities of computer aided techniques as well as their limitations and future possibilities.The first project concerns the three-dimensional reconstruction of the neuritic plaques found in the brains of patients with Alzheimer's disease. We have developed a software package “Synu” for investigation of 3D data sets which has been used in conjunction with laser confocal light microscopy to study the structure of the neuritic plaque. Tissue sections of autopsy samples from patients with Alzheimer's disease were double-labeled for tau, a cytoskeletal marker for abnormal neurites, and synaptophysin, a marker of presynaptic terminals.


2012 ◽  
Vol 17 (4) ◽  
pp. 319-326 ◽  
Author(s):  
Zbigniew Chaniecki ◽  
Krzysztof Grudzień ◽  
Tomasz Jaworski ◽  
Grzegorz Rybak ◽  
Andrzej Romanowski ◽  
...  

Abstract The paper presents results of the scale-up silo flow investigation in based on accelerometer signal analysis and Wi-Fi transmission, performed in distributed laboratory environment. Prepared, by the authors, a set of 8 accelerometers allows to measure a three-dimensional acceleration vector. The accelerometers were located outside silo, on its perimeter. The accelerometers signal changes allowed to analyze dynamic behavior of solid (vibrations/pulsations) at silo wall during discharging process. These dynamic effects are caused by stick-slip friction between the wall and the granular material. Information about the material pulsations and vibrations is crucial for monitoring the interaction between silo construction and particle during flow. Additionally such spatial position of accelerometers sensor allowed to collect information about nonsymmetrical flow inside silo.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jonas Albers ◽  
Angelika Svetlove ◽  
Justus Alves ◽  
Alexander Kraupner ◽  
Francesca di Lillo ◽  
...  

AbstractAlthough X-ray based 3D virtual histology is an emerging tool for the analysis of biological tissue, it falls short in terms of specificity when compared to conventional histology. Thus, the aim was to establish a novel approach that combines 3D information provided by microCT with high specificity that only (immuno-)histochemistry can offer. For this purpose, we developed a software frontend, which utilises an elastic transformation technique to accurately co-register various histological and immunohistochemical stainings with free propagation phase contrast synchrotron radiation microCT. We demonstrate that the precision of the overlay of both imaging modalities is significantly improved by performing our elastic registration workflow, as evidenced by calculation of the displacement index. To illustrate the need for an elastic co-registration approach we examined specimens from a mouse model of breast cancer with injected metal-based nanoparticles. Using the elastic transformation pipeline, we were able to co-localise the nanoparticles to specifically stained cells or tissue structures into their three-dimensional anatomical context. Additionally, we performed a semi-automated tissue structure and cell classification. This workflow provides new insights on histopathological analysis by combining CT specific three-dimensional information with cell/tissue specific information provided by classical histology.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2858
Author(s):  
Kelly Ka-Lee Lai ◽  
Timothy Tin-Yan Lee ◽  
Michael Ka-Shing Lee ◽  
Joseph Chi-Ho Hui ◽  
Yong-Ping Zheng

To diagnose scoliosis, the standing radiograph with Cobb’s method is the gold standard for clinical practice. Recently, three-dimensional (3D) ultrasound imaging, which is radiation-free and inexpensive, has been demonstrated to be reliable for the assessment of scoliosis and validated by several groups. A portable 3D ultrasound system for scoliosis assessment is very much demanded, as it can further extend its potential applications for scoliosis screening, diagnosis, monitoring, treatment outcome measurement, and progress prediction. The aim of this study was to investigate the reliability of a newly developed portable 3D ultrasound imaging system, Scolioscan Air, for scoliosis assessment using coronal images it generated. The system was comprised of a handheld probe and tablet PC linking with a USB cable, and the probe further included a palm-sized ultrasound module together with a low-profile optical spatial sensor. A plastic phantom with three different angle structures built-in was used to evaluate the accuracy of measurement by positioning in 10 different orientations. Then, 19 volunteers with scoliosis (13F and 6M; Age: 13.6 ± 3.2 years) with different severity of scoliosis were assessed. Each subject underwent scanning by a commercially available 3D ultrasound imaging system, Scolioscan, and the portable 3D ultrasound imaging system, with the same posture on the same date. The spinal process angles (SPA) were measured in the coronal images formed by both systems and compared with each other. The angle phantom measurement showed the measured angles well agreed with the designed values, 59.7 ± 2.9 vs. 60 degrees, 40.8 ± 1.9 vs. 40 degrees, and 20.9 ± 2.1 vs. 20 degrees. For the subject tests, results demonstrated that there was a very good agreement between the angles obtained by the two systems, with a strong correlation (R2 = 0.78) for the 29 curves measured. The absolute difference between the two data sets was 2.9 ± 1.8 degrees. In addition, there was a small mean difference of 1.2 degrees, and the differences were symmetrically distributed around the mean difference according to the Bland–Altman test. Scolioscan Air was sufficiently comparable to Scolioscan in scoliosis assessment, overcoming the space limitation of Scolioscan and thus providing wider applications. Further studies involving a larger number of subjects are worthwhile to demonstrate its potential clinical values for the management of scoliosis.


2019 ◽  
Vol 93 (12) ◽  
pp. 2651-2660 ◽  
Author(s):  
Sergey Samsonov

AbstractThe previously presented Multidimensional Small Baseline Subset (MSBAS-2D) technique computes two-dimensional (2D), east and vertical, ground deformation time series from two or more ascending and descending Differential Interferometric Synthetic Aperture Radar (DInSAR) data sets by assuming that the contribution of the north deformation component is negligible. DInSAR data sets can be acquired with different temporal and spatial resolutions, viewing geometries and wavelengths. The MSBAS-2D technique has previously been used for mapping deformation due to mining, urban development, carbon sequestration, permafrost aggradation and pingo growth, and volcanic activities. In the case of glacier ice flow, the north deformation component is often too large to be negligible. Historically, the surface-parallel flow (SPF) constraint was used to compute the static three-dimensional (3D) velocity field at various glaciers. A novel MSBAS-3D technique has been developed for computing 3D deformation time series where the SPF constraint is utilized. This technique is used for mapping 3D deformation at the Barnes Ice Cap, Baffin Island, Nunavut, Canada, during January–March 2015, and the MSBAS-2D and MSBAS-3D solutions are compared. The MSBAS-3D technique can be used for studying glacier ice flow at other glaciers and other surface deformation processes with large north deformation component, such as landslides. The software implementation of MSBAS-3D technique can be downloaded from http://insar.ca/.


Author(s):  
Stephan Uhkoetter ◽  
Stefan aus der Wiesche ◽  
Michael Kursch ◽  
Christian Beck

The traditional method for hydrodynamic journal bearing analysis usually applies the lubrication theory based on the Reynolds equation and suitable empirical modifications to cover turbulence, heat transfer, and cavitation. In cases of complex bearing geometries for steam and heavy-duty gas turbines this approach has its obvious restrictions in regard to detail flow recirculation, mixing, mass balance, and filling level phenomena. These limitations could be circumvented by applying a computational fluid dynamics (CFD) approach resting closer to the fundamental physical laws. The present contribution reports about the state of the art of such a fully three-dimensional multiphase-flow CFD approach including cavitation and air entrainment for high-speed turbo-machinery journal bearings. It has been developed and validated using experimental data. Due to the high ambient shear rates in bearings, the multiphase-flow model for journal bearings requires substantial modifications in comparison to common two-phase flow simulations. Based on experimental data, it is found, that particular cavitation phenomena are essential for the understanding of steam and heavy-duty type gas turbine journal bearings.


2013 ◽  
Vol 318 ◽  
pp. 572-575
Author(s):  
Li Li Yu ◽  
Yu Hong Li ◽  
Ai Feng Wang

In this paper a quality monitoring system for seismic while drilling (SWD) that integrates the whole process of data acquisition was developed. The acquisition equipment, network status and signals of accelerometer and geophone were monitored real-time. With fast signal analysis and quality evaluation, the acquisition parameters and drilling engineering parameters can be adjusted timely. The application of the system can improve the quality of data acquisition and provide subsequent processing and interpretation with high qualified reliable data.


Radiology ◽  
1996 ◽  
Vol 199 (1) ◽  
pp. 37-40 ◽  
Author(s):  
C P Davis ◽  
M E Ladd ◽  
B J Romanowski ◽  
S Wildermuth ◽  
J F Knoplioch ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document