scholarly journals A Literature Review Study on Atomic Ions Dissolution of Titanium and Its Alloys in Implant Dentistry

Materials ◽  
2019 ◽  
Vol 12 (3) ◽  
pp. 368 ◽  
Author(s):  
Sammy Noumbissi ◽  
Antonio Scarano ◽  
Saurabh Gupta

This review of literature paper was done in order to conduct a review of the literature and an assessment of the effects of titanium implant corrosion on peri-implant health and success in the oral environment. This paper evaluates and critically reviews the findings of the multiple in-depth in vivo and in vitro studies that are related to corrosion aspects of the titanium and its alloys. A literature survey was conducted by electronic search in Medline and studies that were published between 1940 and August 2018 were selected. The search terms used were types of corrosion, corrosion of titanium implants, titanium corrosion, metal ion release from the titanium implants, fretting and pitting corrosion, implant corrosion, peri implantitis, and corrosion. Both in vivo and in vitro studies were also included in the review. The search and selection resulted in 64 articles. These articles were divided on the basis of their context to different kinds of corrosion related to titanium dental implants. It is evident that metal ions are released from titanium and titanium alloy dental implants as a result of corrosion. Corrosion of implants is multifactorial, including electrical, chemical, and mechanical factors, which have an effect on the peri-implant tissues and microbiota. The literature surveyed showed that corrosion related to titanium and its alloys has an effect on the health of peri-implant soft and hard tissue and the long term survival of metal dental implants. It can be concluded that presence of the long-term corrosion reaction along with continuous corrosion leads to the release of ions into the peri-implant tissue but also to a disintegration of the implant that contribute to material fatigue and even fracture of the abutments and implant body or both. This combined impact of the corrosion, bacterial activity, chemical reactions, and functional stresses are to be looked at as important factors of implant failure. The findings can be used to explore the possible strategies of research to investigate the biological impact of implant materials.

2021 ◽  
Vol 12 ◽  
Author(s):  
Sung-Hyun Kim ◽  
Jin Hee Lee ◽  
Kikyung Jung ◽  
Jun-Young Yang ◽  
Hyo-Sook Shin ◽  
...  

Human skins are exposed to nanomaterials in everyday life from various sources such as nanomaterial-containing cosmetics, air pollutions, and industrial nanomaterials. Nanomaterials comprising metal haptens raises concerns about the skin sensitization to nanomaterials. In this study, we evaluated the skin sensitization of nanomaterials comparing metal haptens in vivo and in vitro. We selected five metal oxide NPs, containing copper oxide, cobalt monoxide, cobalt oxide, nickel oxide, or titanium oxide, and two types of metal chlorides (CoCl2 and CuCl2), to compare the skin sensitization abilities between NPs and the constituent metals. The materials were applied to KeratinoSensTM cells for imitated skin-environment setting, and luciferase induction and cytotoxicity were evaluated at 48 h post-incubation. In addition, the response of metal oxide NPs was confirmed in lymph node of BALB/C mice via an in vivo method. The results showed that CuO and CoO NPs induce a similar pattern of positive luciferase induction and cytotoxicity compared to the respective metal chlorides; Co3O4, NiO, and TiO2 induced no such response. Collectively, the results implied fast-dissolving metal oxide (CuO and CoO) NPs release their metal ion, inducing skin sensitization. However, further investigations are required to elucidate the mechanism underlying NP-induced skin sensitization. Based on ion chelation data, metal ion release was confirmed as the major “factor” for skin sensitization.


Coatings ◽  
2019 ◽  
Vol 9 (5) ◽  
pp. 282 ◽  
Author(s):  
Mokhamad Fakhrul Ulum ◽  
Wahyu Caesarendra ◽  
Reza Alavi ◽  
Hendra Hermawan

Absorbable metals have been introduced as materials to fabricate temporary medical implants. Iron, magnesium and zinc have been considered as major base elements of such metals. The metallurgical characterization and in-vitro corrosion assessment of these metals have been covered by the new ASTM standards F3160 and F3268. However, the in-vivo corrosion characterization and assessment of absorbable metal implants are not yet well established. The corrosion of metals in the in-vivo environment leads to metal ion release and corrosion product formation that may cause excessive toxicity. The aim of this work is to introduce the techniques to assess absorbable metal implants and their in-vivo corrosion behavior. This contains the existing approaches, e.g., implant retrieval and histological analysis, ultrasonography and radiography, and the new techniques for real-time in-vivo corrosion monitoring.


2020 ◽  
Vol 11 (3) ◽  
pp. 86-92 ◽  
Author(s):  
Wilhelm Niedermeier ◽  
Katrin Huesker

Background/purpose: Combination of dental titanium implants with other prosthetic metallic components may lead to metal ion release that increases the risk of adverse reactions in patients. The present study therefore aimed to determine in vitro metal ion dissolution from different alloy combinations. Materials and methods: Dental alloys were subjected to a lactic acid immersion test together with titanium implants and matched with controls. Between day 1 and 38, open direct current potentials (DCP) between the samples and the electrolyte were recorded and metal dissociation inside the electrolyte was assessed using ICP-MS. Results: Absolute DCPs of the different alloys increased significantly (p<0.001) from 100-150mV to 490-580 mV within the first two weeks of immersion, dropping to about 450mV later on largely independent of the material. Titanium showed highest dissociation rates (2.00-12.06µg/cm2 per day; p=0.0002); all other components demonstrated poor corrosive dissolution (<0.6µg/cm2 per day). After immersion of 38 days, titanium still yielded high dissociation (0.64-1.38µg/cm2 per day) for all test groups. Presence of fine gold inside the electrolyte significantly increased dissociation of titanium (p=0.027). Dissociation of iron indicated contamination from tool components used for implant production. Optical examination of non-precious metal surfaces showed no corrosive discoloration after 5 or 26 weeks of lactic acid immersion. Conclusion: Within the limitations of this study, there is no objection against the use of non-precious alloys for the fabrication of components and prostheses supported on titanium implants if gold is not present inside the same electrolyte.


Coatings ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 857
Author(s):  
Lasni Samalka Kumarasinghe ◽  
Neethu Ninan ◽  
Panthihage Ruvini Lakshika Dabare ◽  
Alex Cavallaro ◽  
Esma J. Doğramacı ◽  
...  

The metal ion release characteristics and biocompatibility of meta-based materials are key factors that influence their use in orthodontics. Although stainless steel-based alloys have gained much interest and use due to their mechanical properties and cost, they are prone to localised attack after prolonged exposure to the hostile oral environment. Metal ions may induce cellular toxicity at high dosages. To circumvent these issues, orthodontic brackets were coated with a functional nano-thin layer of plasma polymer and further immobilised with enantiomers of tryptophan. Analysis of the physicochemical properties confirmed the presence of functional coatings on the surface of the brackets. The quantification of metal ion release using mass spectrometry proved that plasma functionalisation could minimise metal ion release from orthodontic brackets. Furthermore, the biocompatibility of the brackets has been improved after functionalisation. These findings demonstrate that plasma polymer facilitated surface functionalisation of orthodontic brackets is a promising approach to reducing metal toxicity without impacting their bulk properties.


2021 ◽  
Vol 108 (Supplement_6) ◽  
Author(s):  
H Khatkar ◽  
M Prokopenko

Abstract Aim In vitro knee simulation has demonstrated favourable wear properties and decreased metal ion release of ceramic coated metal femoral components in total knee arthroplasty surgery. Femoral implants coated with ceramic have been used in patients, however the subsequent clinical performance and time-to-revision of these implants is largely unknown. The scope of this study was to review the current available clinical literature, focusing on retrieval studies of Ceramic-Coated TKAs. Method Literature review of PubMed and MEDLINE. All studies included demonstrated clinical evaluation of implant performance, either in vivo or at revision. Results 9 studies were identified and included for analysis in this study. Retrieval analysis has illustrated microscopic defects in coatings of revised implants, with associated abrasion and 3rd body wear of the polyethylene component. Evidence suggests that coating femoral components with ceramic can prevent effective cement bonding, leading to aseptic loosening and thus earlier implant failure. Despite these problems, high volume centres have been able to demonstrate comparable results when compared with traditional bearing surface combinations. The mechanism behind metal ion hypersensitivity is currently poorly understood; however, the use of ceramic coated knee replacements is demonstrating a reduction in metal ion release. Conclusions Whilst conferring favourable clinical properties in certain instances, the lack of surgical, implant and patient data surrounding the use of this coated implants remains concerning. The literature base remains limited, and meaningful clinical conclusions cannot be drawn. Recommendations include performing robust clinical trials in order to delineate the clinical efficacy of ceramic coatings in knee arthroplasty.


2021 ◽  
pp. 030157422110373
Author(s):  
Prasad Chitra ◽  
GS Prashantha ◽  
Arun Rao ◽  
Harshvardhan S Jois

Introduction: Fluoride agents to prevent white spot lesions are used often during orthodontic treatment. The beneficial effects of fluoride, when consumed within permissible limits on dental structures, are well known. Their implications on underlying biological tissues, however, are unknown. Mouthwashes and dentifrices with fluorides are associated with metal ion release into the mouth with possible cell genotoxicity. Since these cariostatic agents are frequently used during orthodontic therapy, a deeper understanding of the effects of fluoride on oral tissues was considered necessary. Methodology: Three groups of patients (30 each)—group 1 (untreated controls), group 2 (non-fluoridated), and group 3 (Fluoridated) were analyzed. Patients in groups 2 and 3 were bonded with the same bracket prescription and treated with similar archwire sequences. Buccal mucosal cells at 4 specific time periods (before treatment, 1 week, 30 days, and 6 months) were collected, using a wooden tongue depressor, and assessed for any nuclear abnormalities. Comparisons of changes were made with an untreated control group and also between the non-fluoridated and fluoridated groups. Relevant conclusions were drawn after analysis of the results. Results: Greater number of nuclei were observed at the 30-day time interval in the fluoridated group, which was statistically significant at P < .001. Conclusion: Use of fluoridated oral hygiene products in patients undergoing fixed orthodontic treatment with NiTi archwires could increase the risk of micronuclei formation in buccal mucosal cells.


2019 ◽  
Vol 7 (3) ◽  
pp. 90 ◽  
Author(s):  
Eleana Kontonasaki ◽  
Athanasios E. Rigos ◽  
Charithea Ilia ◽  
Thomas Istantsos

The purpose of this paper was to update the knowledge concerning the wear, translucency, as well as clinical performance of monolithic zirconia ceramics, aiming at highlighting their advantages and weaknesses through data presented in recent literature. New ultra-translucent and multicolor monolithic zirconia ceramics present considerably improved aesthetics and translucency, which, according to the literature reviewed, is similar to those of the more translucent lithium disilicate ceramics. A profound advantage is their high strength at thin geometries preserving their mechanical integrity. Based on the reviewed articles, monolithic zirconia ceramics cause minimal wear of antagonists, especially if appropriately polished, although no evidence still exists regarding the ultra-translucent compositions. Concerning the survival of monolithic zirconia restorations, the present review demonstrates the findings of the existing short-term studies, which reveal promising results after evaluating their performance for up to 5 or 7 years. Although a significant increase in translucency has been achieved, new translucent monolithic zirconia ceramics have to be further evaluated both in vitro and in vivo for their long-term potential to preserve their outstanding properties. Due to limited studies evaluating the wear properties of ultra-translucent material, no sound conclusions can be made, whereas well-designed clinical studies are urgently needed to enlighten issues of prognosis and long-term survival.


Sign in / Sign up

Export Citation Format

Share Document