scholarly journals Effect of Conventional Adhesive Application or Co-Curing Technique on Dentin Bond Strength

Materials ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 7664
Author(s):  
Josipa Vukelja ◽  
Eva Klarić Sever ◽  
Ivan Sever ◽  
Silvana Jukić Krmek ◽  
Zrinka Tarle

The aim of this in vitro study was to assess the effect of two different adhesive application methods on shear dentin bond strength (ISO 29022) using three various adhesive systems. A mid-coronal section of 77 intact third human molars with fully developed apices was made to create flat bonding substrates. The materials used in the study were Excite F (Ivoclar Vivadent), Prime&Bond Universal (Dentsply Sirona) and G-Premio Bond (GC). The application of each adhesion system was performed in two different ways. In the first group, the bonding agent was light cured immediately after the application (conventional method), while in the second group the adhesive and composite were cured concurrently (“co-curing” method). A total of 180 specimens were prepared (3 adhesives × 2 method of application × 30 specimens per experimental group), stored at 37 °C in distilled water and fractured in shear mode after 1 week. Statistical analysis was performed using ANOVA and Weibull statistics. The highest bond strength was obtained for Prime&Bond conventional (21.7 MPa), whilst the lowest bond strength was observed when co-curing was used (particularly, Excite F 12.2 MPa). The results showed a significant difference between conventional and co-curing methods in all materials. According to reliability analysis, the co-curing method diminished bond reliability. Different application techniques exhibit different bond strengths to dentin.

2015 ◽  
Vol 5 (1) ◽  
pp. 22-26
Author(s):  
Muzin Shahi Shaik ◽  
Snigdha Pattanaik ◽  
Sudhakar Pathuri ◽  
Arunachalam Sivakumar

Introduction: Bond strength is an important property and determines the amount of force delivered and treatment duration in orthodontics. Many light-cured bonding materials are being used; but it is required to determine the most efficient one withdesired bond strength. Objective: To determine and compare the shear bond strength of three visible light-cured composites (Transbond XT, Heliositand Enlight) and two self-cured composites (Rely-a-bond and Concise). Materials & Method: 100 extracted premolars were collected and randomly divided into 5 test groups of different adhesives. Brackets were bonded to the teeth in each test group with the respective adhesive according to the manufacturer’s instructions. Each specimen was debonded using Universal Testing Machine and the shear bond strength for each specimen was calculated. All the groups were compared by ANOVA one-way test. Results: There were statistically significant differences among the five groups (P<0.05). The shear bond strength of Enlight (13.92 ± 3.92) is similar to Transbond XT (14.30 ± 4.35). Conclusion: Light cure composites showed higher bond strength than self cure composites.


2016 ◽  
Vol 17 (12) ◽  
pp. 997-1002 ◽  
Author(s):  
Fahad I Alkhudhairy ◽  
Zeeshan H Ahmad

ABSTRACT Introduction Various bulk-fill materials depending on their composition, viscosity, and flow ability have different physical and mechanical properties. The aim of this in vitro study was to determine and compare the shear bond strength and microleakage properties of activa restorative with other bulk-fill restorative materials surefil (SDR), Biodentine, ever X posterior. Materials and methods Forty permanent premolars were selected for shear bond strength, and 20 permanent premolars were selected with class II cavities on mesial and distal side for microleakage. Universal testing device was used to assess the shear bond strength. Microleakage was checked using dye penetration method under a stereomicroscope. Mean and standard deviation values were calculated from the recorded values. Intergroup comparison was done by one-way analysis of variance (ANOVA) followed by pairwise comparison using Tukey honestly significant difference (HSD) post hoc test. Results The mean shear bond strength was highest for SDR surefil followed by Ever X posterior, Bioactive restorative, and Biodentine respectively. In this study, SDR (surefil) showed better shear bond strength and better microleakage properties compared with the other test materials (F = 186.7157, p < 0.05). Conclusion The result of this study showed that flowable and fiber-reinforced composites have better shear bond strength and microleakage properties. Clinical significance Flowable bulk-fill composite resins can be used as dentin substitutes because of its superior properties. How to cite this article Alkhudhairy FI, Ahmad ZH. Comparison of Shear Bond Strength and Microleakage of Various Bulk-fill Bioactive Dentin substitutes: An in vitro study. J Contemp Dent Pract 2016;17(12):997-1002.


2013 ◽  
Vol 24 (3) ◽  
pp. 279-283 ◽  
Author(s):  
Ana Caroline Silva Gama ◽  
Andre Guaraci de Vito Moraes ◽  
Lilyan Cardoso Yamasaki ◽  
Alessandro Dourado Loguercio ◽  
Ceci Nunes Carvalho ◽  
...  

The purpose of this study was to evaluate in vitro the shear bond strength to enamel, flexural strength, flexural modulus, and contraction stress of one orthodontic composite and two flowable composites. Orthodontic brackets were bonded to 45 human maxillary premolars with the composites Transbond XT, Filtek Z-350 flow and Opallis flow and tested for shear bond strength. For measurement of flexural strength and flexural modulus, specimens were fabricated and tested under flexion. For the contraction stress test, cylindrical specimens were tested and an extensometer determined the height of the specimens. The data were subjected to one-way ANOVA and Tukey's test (α=0.05). The shear bond strength values were significantly lower (p<0.05) for the flowable composites compared with the orthodontic composite. For the flexural strength, no statistically significant difference was found among the composites (p>0.05) while the flexural modulus was significantly higher (p<0.05) for Transbond XT than for Filtek Z-350 flow and Opallis flow. The orthodontic composite presented significantly lower contraction stress values than the flowable composites (p<0.05). The light-activated orthodontic composite material presented higher flexural modulus and shear bond strength and lower contraction stress than both flowable composites.


2017 ◽  
Vol 11 (01) ◽  
pp. 058-063 ◽  
Author(s):  
Vini Rajeev ◽  
Rajeev Arunachalam ◽  
Sanjna Nayar ◽  
P. R. Arunima ◽  
Sivadas Ganapathy ◽  
...  

ABSTRACT Objective: This in vitro study was designed to assess shear bond strength (SBS) of ormocer flowable (OF) resin as a luting agent, ormocer as an indirect veneer material with portrayal of modes of failures using scanning electron microscope (SEM). Materials and Methods: Sixty maxillary central incisors were divided into Group I, II, and III with 20 samples each based on luting cement used. They were OF, self-adhesive (SA) cement, and total etch (TE) cement. These groups were subdivided into “a” and “b” of ten each based on the type of veneering materials used. Veneer discs were fabricated using Ormocer restorative (O) and pressable ceramic (C). Specimens were thermocycled and loaded under universal testing machine for SBS. The statistical analysis was done using one-way ANOVA post hoc Tukey honest significant difference method. Results: A significant difference was observed between the Groups I and II (P < 0.05). The highest mean bond strength when using ormocer veneer was obtained with the Group Ia (19.11 ± 1.92 Mpa) and lowest by Group IIa (8.1 ± 1.04 Mpa), whereas the highest mean bond strength while using ceramic veneer was of similar range for Group Ib (18.04 ± 4.08 Mpa) and Group IIIb (18.07 ± 1.40 Mpa). SEM analysis revealed OF and TE presented mixed type of failure when compared with SA where failure mode was totally adhesive. Conclusion: OF was found equally efficient like TE. Bond strength of ormocer as a veneer was not inferior to ceramic making it one of the promising additions in the field of dentistry.


2018 ◽  
Vol 6 (02/03) ◽  
pp. 106-111
Author(s):  
Ramandeep Kaur ◽  
Manjit Kumar ◽  
Shailesh Jain ◽  
Neha Jindal

Abstract Statement of Problem The adhesion of impression material to impression tray is very important. Tray adhesive plays a major role in making accurate impression. Although manufactures recommend the use of particular tray adhesives, comparison of their affective adhesiveness has not been reported. The effect of use of tray adhesives on dimensional accuracy of dies has not been established. Purpose The aim of this study was to compare the dimensional accuracy of dies using different tray adhesives at different time intervals. Materials and Methods First part of study comprised 120 samples in six groups with 20 samples in each group. First group comprised samples with no tray adhesive, and in other five groups, different types of tray adhesives were applied. The dies obtained were evaluated for upper diameter, lower diameter, and occlusogingival height. In the second part, there were a total of 125 samples in five groups with 25 samples in each group. Five different types of tray adhesive were applied for five different time intervals 5, 10, 15, 20, and 25 minutes, respectively. The specimens were tested in tensile mode for its debonding force at a crosshead speed of 5 mm/min, until separation failure occurred. Results Significant difference was seen for upper and lower diameters when compared with the group without any tray adhesive. The maximum bond strength was found in the group in which tray adhesive was applied for 20 minutes.


2020 ◽  
Vol 24 (1) ◽  
pp. 21-28
Author(s):  
Ediz Kale ◽  
Ayça Deniz İzgi ◽  
Remzi Niğiz

SummaryBackground/Aim: The purpose of this in-vitro study was to compare the resin-bonded fixed partial dentures (RBFPD) fabricated using two different structural designs and two different antibacterial adhesive lutting protocols in regard to their resistance to debonding.Material and Methods: Forty samples for a model with single missing molar were divided into 4 groups (M1, M2, C1, C2) (n=10). M1 and M2 were prepared in accordance with modified inlay slot-cavity retained RBFPD design; C1 and C2 were prepared according to conventional inlay slot-cavity retained RBFPD design. M1 and C1 cavities were treated with 2% chlorhexidine-based (CHX) cavity disinfectant and 10-methacryloyloxydecyl dihydrogen phosphate (MDP) containing adhesive system; M2 and C2 cavities were treated with MDP and 12-methacryloyloxydodecylpyridinium bromide (MDPB) containing adhesive system featuring antibacterial cavity cleansing effect. The RBFPDs were made of base-metal alloy and their fit surfaces sandblasted with aluminium oxide (Al2O3). Adhesive resin cement was used for cementation, and the RBFPD retainers were interlocked into their corresponding inlay cavities using composite resin. After 1 week being immersed in aqueous environment, the RBFPDs were subjected to tensile loading at a crosshead speed of 1 mm/min until failure. One way ANOVA and Tukey HSD tests were used for statistical evaluation (α=0.05). Mode of failure and tooth damage was also noted.Results: Mean tensile bond strength values were 356 N for M1, 305 N for M2, 467 N for C1, and 455 N for C2. Tensile strength values of C1 and C2 were significantly higher than those of M1 and M2 (p<0.05). The mode of failure was mostly adhesive in character at the metal-cement interface in all groups. Tooth fracture was observed nearly in all specimens. No significant difference was detected between the antibacterial adhesive lutting protocols (p>0.05).Conclusions: The RBFPDs with the conventional design were found to be more retentive than those with the modified design. Using an adhesive system featuring antibacterial properties with no need of separate antibacterial agent application during bonding may be favourable.


2019 ◽  
Vol 13 (1) ◽  
pp. 255-260
Author(s):  
Francisco Molina ◽  
Karina Maria Salvatore Freitas ◽  
Maria Cristina Rockenbach Binz Ordóñez ◽  
Emerson Flamarion Cruz ◽  
Rafael Pinelli Henriques ◽  
...  

Objective: The objective of this study was to evaluate in vitro the shear bond strength of two types of MIM (Metal Injection Molding) technology brackets, one with conventional mesh base and the other with rail-shaped mesh base. Materials and Methods: Forty human premolars received the bonding of 2 types of brackets: Group 1- 20 Synergy metal brackets (Rocky Mountain) with conventional mesh base and Group 2-20 H4 brackets (OrthoClassic) with rail-shaped mesh base. Both brackets were bonded with Resilience photopolymerizable resin (OrthoTechnology). The specimens were coupled to a Tinius Olsen universal test machine where the shear test was performed using a chisel. In addition, the amount of remaining resin in tooth crown with the ImageJ program was evaluated and the Adhesive Remnant Index (ARI). Intergroup comparison was performed by the independent t test and Chi-square test. Results: There was no statistically significant difference between the groups for any of the measures evaluated indicating that the mesh type of the brackets’ base with MIM technology did not influence the shear bond strength of the brackets (shear bond strength, p=0.191; maximum load registered, p=0.244). There was also no difference between the percentage (p=0.602) and area of remaining resin in the teeth (p=0.805) and IRA (p=0.625) between the Synergy and H4 groups. Conclusion: Shear bond strength was similar in the two types of brackets with MIM technology evaluated. In addition, the remaining resin in the dental enamel of two types of brackets were also similar.


2021 ◽  
Vol 58 (1) ◽  
pp. eUJ3657
Author(s):  
Germano Brandão ◽  
◽  
Liliana Ávila Maltagliati ◽  
Ana Carla Raphaelli Nahás-Scocate ◽  
Murilo Matias ◽  
...  

The objective of this in vitro study was to assess and compare the shear bond strength of conventional and modified orthodontic tubes bonded to the surface of dry and saliva-contaminated enamel. The sample consisted of 40 human teeth, which were randomly divided into four groups according to attachment base and presence or absence of saliva contamination as follows: Group CB, conventional orthodontic tubes without salivary contamination; Group CB-S, conventional orthodontic tubes with salivary contamination; Groups BM, orthodontic tubes modified by welding a metal mesh to their base without salivary contamination; and Group BM-S, modified orthodontic tubes with salivary contamination. Shear bond strength test was performed in a universal testing machine and analysis of the adhesive remnant index (ARI) by optical microscopy. Two-way ANOVA was used, followed by Tukey’s test at a statistical significance level of 5%. The ARI results were analysed descriptively. There was statistically significant difference between the groups regarding the shear bond strength values, with conventional tubes presenting significantly higher values (P < 0.05). In addition, the presence of salivary contamination interfered negatively with the behaviour of conventional tubes only (P < 0.05). Shear bond strength was not improved by increasing the area of the orthodontic tubes. Moreover, salivary contamination influenced negatively the SBS values, but only when conventional tubes were used.


2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Jiakang Zhu ◽  
Jing Gao ◽  
Luming Jia ◽  
Xin Tan ◽  
Chenyang Xie ◽  
...  

Abstract Background The purpose of this in vitro study was to evaluate the effect of the percentages of preserved enamel on ceramic laminate veneers’ (CLVs) shear bond strength (SBS). Methods Seventy extracted human maxillary central incisors were scanned and reconstructed into three-dimensional models. The extracted teeth were then embedded and randomly divided into seven groups (n = 10 per group). Based on digital analyses of the three-dimensional models, guided tooth preparation and bonding procedures were performed individually to form seven different percentages (100%, 80%, 60% 50%, 40%, 20% and 0%) of remaining enamel thickness on the bonding surface. Finally, the SBS test was performed, and the data were statistically analysed by one-way ANOVA with LSD post hoc test (α = 0.05). Results The complete enamel surface exhibited the highest SBS (19.93 ± 4.55 MPa), followed by 80% enamel (19.03 ± 3.66 MPa), 60% enamel (18.44 ± 3.65 MPa), 50% enamel (18.18 ± 3.41 MPa), 40% enamel (17.83 ± 3.01 MPa) and 20% enamel (11.32 ± 3.42 MPa) group. The lowest SBS (9.63 ± 3.46 MPa) was detected in 0% enamel group. No significant difference was observed among the 40–100% enamel groups, while the 20% or 0% enamel group demonstrated a significantly lower mean SBS than the 40% enamel group (p < 0.05). Conclusion The SBS value of CLVs bonded to 100% enamel on the finishing surfaces (nearly 20 MPa) was twice that which bonded to 0% enamel (nearly 10 MPa). Bonding to 100% enamel is the most reliable treatment. When dentin exposure is inevitable, enamel should be preserved as much as possible to maintain good bonding. In addition, 40% of preserved enamel on the bonding surface was the minimal acceptable value to fulfil the requirements of good bonding strength.


2021 ◽  
Vol 45 (3) ◽  
pp. 177-185
Author(s):  
Moaz H Attar ◽  
Medhat A Abdallah ◽  
Hussein A Alharthy ◽  
Omar A El Meligy

Objectives: To investigate the effect of Co-curing versus Staged-curing and No-bonding on retention of different resin-based sealants (RBS). Study design: For shear bond strength (SBS) and microleakage tests, 90 extracted premolars were divided equally into 3 groups (I, II, III). Each group was further subdivided equally into 3 subgroups (a, b, c). No-bonding subgroups did not receive a bonding agent, Staged-curing subgroups received a bonding agent that was cured before sealant application, while Co-curing subgroups received a bonding agent that was cured after sealant application. Seal-it was applied for group I, Helioseal-F for group II and Clinpro for group III. SBS buttons were tested using Instron machine, while microleakage specimens were examined using micro-CT. Results: Clinpro showed the highest SBS values in Staged-curing and No-bonding groups (8.72±2.39, 12.51±3.16) respectively. Staged-curing was significantly greater in SBS values than those for other groups (P&lt;0.05). There was a significant difference in microleakage values of Staged-curing among different RBS (P = 0.003), while there was no significant difference in values of No-bonding and Co-curing among different RBS (P = 0.541, P = 0.521). Conclusions: The use of a bonding agent as Staged-curing was more effective in improving sealant retention than No-bonding and Co-curing.