scholarly journals Effect Steel Fibre Content on the Load-Carrying Capacity of Fibre-Reinforced Concrete Expansion Anchor

Materials ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 7757
Author(s):  
Daniel Dudek ◽  
Marta Kadela ◽  
Marcin Małek

The article presents the pull-out strength tests carried out on M10 expansion anchors in non-cracked and cracked concrete with a crack width cw = 0.30 mm. The breaking loads and the average pull-out strength of anchors in fibre-reinforced concrete substrates were determined. Fibre content ratios of 15, 30 and 50 kg/m3 were used. In addition, two different classes of concrete (C20/25 and C50/60) were tested. The addition of steel fibres caused a decrease in the pull-out strength by 5% for non-cracked concrete of C20/25 class and fibre content up to 30 kg/m3 and a further 7% for the remaining specified dosage. While for concrete of the C50/60 class, it a decrease in the pull-out strength of up to 20% was observed. For cracked concrete class C20/25 with crack initiation cw = 0.30 mm, the reduction was from 9% to 16% in relation to non-cracked concrete and a maximum of 18% for the fibre content of 50 kg/m3. The difference between the tensile load capacity of C50/60 class cracked and non-cracked concrete was lower than 5% and fell within the measurement error.

2009 ◽  
Vol 34 (5) ◽  
pp. 643-650 ◽  
Author(s):  
H. OMAE ◽  
C. ZHAO ◽  
Y.-L. SUN ◽  
M. E. ZOBITZ ◽  
S. L. MORAN ◽  
...  

The purpose of this study was to assess tendon metabolism and suture pull-out strength after simple tendon suture in a tissue culture model. One hundred and twelve flexor digitorum profundus tendons from 28 dogs were cultured for 7, 14, or 21 days with or without a static tensile load. In both groups increased levels of matrix metalloproteinase (MMP) mRNA was noted. Suture pull-out strength did not decrease during tissue culture. While the presence of a static load had no effect on the pull-out strength, it did affect MMP mRNA expression. This tissue culture model could be useful in studying the effect of factors on the tendon-suture interface.


2021 ◽  
Vol 28 (1) ◽  
pp. 71-83
Author(s):  
Mazin Abdulrahman ◽  
Shakir Salih ◽  
Rusul Abduljabbar

In this research, an experimental study is conducted to investigate the behavior and strength of high strength reinforced concrete corbels externally bonded with CFRP fabric sheets and Plates with different patterns taking into account the effect of adopted variables in enhancing the ultimate strength; the effect of shear span to effective depth (a/d), configuration, type and amount of bonding. Eleven high strength reinforced corbels were cast and tested under vertical loads. Test results showed there was an improvement in the behavior and load carrying capacity of all strengthened corbels. An increasing in the ultimate strength of strengthened corbel by inclined CFRP strips reached to (92.1%) while the increasing reached to (84.21%) for using one horizontal CFRP Plates compared to un-strengthened reference specimen. Also, it can be conducted that the increase of (a/d) ratio from (0.6 to 0.8) resulted in decreasing by 21.05% in ultimate load capacity of corbels and from (0.4 to 0.6) by 31.25% and 58.69% in cracking and ultimate loads respectively Using CFRP .


2014 ◽  
Vol 1611 ◽  
pp. 1-6
Author(s):  
F. J. Baldenebro-Lopez ◽  
J. H. Castorena-Gonzalez ◽  
J. A. Baldenebro-Lopez ◽  
J.I. Velazquez-Dimas ◽  
J. E. Ledezma-Sillas ◽  
...  

ABSTRACTThe increasing use of polymeric reinforcements in concrete structures requires either the development of a new design theory or the adaptation of current designs considering the engineering properties of this type of materials. In this work a method for calculating the deflections of reinforced concrete elements is proposed, which can be used in predicting the flexural behavior of longitudinally reinforced concrete with PET strips in amounts up to 1%. The model theory assumes that concrete has a tensile load capacity different to zero, characterized by a uniaxial tensile stress-strain diagram. A series of tests were conducted to corroborate the validity of the suggested method, showing that the theory also correctly predicts the creep deformation post-cracking. The deflection results of reinforced concrete with recycled PET strips are presented. The tests are carried out by a simple beam with center-point loading, using three different amounts of reinforcement and comparing the experimental results with the theoretical results of the proposed model.


2017 ◽  
Vol 23 (6) ◽  
pp. 806-813 ◽  
Author(s):  
Inmaculada MARTÍNEZ-PÉREZ ◽  
Juozas VALIVONIS ◽  
Remigijus ŠALNA ◽  
Alfonso COBO-ESCAMILLA

The building of structures from steel fibre reinforced concrete (SFRC) in the external and conventional rein­forced concrete (RC) in the internal layer represents an economical alternative of structures effectively using SFRC. The paper presents test results of flexural behaviour of layered beams with SFRC external layers and RC internal layer. The behaviour of these beams is compared to test results of SFRC and conventional RC beams. The test results show, that the flexural load capacity for all series of beams is nearly similar, but the deflections of layered beams are less comparing to monolithic ones. It also been shown that the equations indicated in the Eurocode 2 can be used to design the flexural reinforcement in layered SFRC beams.


Materials ◽  
2019 ◽  
Vol 12 (22) ◽  
pp. 3786 ◽  
Author(s):  
Abubaker A. M. Ahmed ◽  
Yanmin Jia

A comprehensive program of experiments consisting of compression, uniaxial compression, direct shear, flexural as well as splitting tensile and air permeability tests were performed to analyse the effect of the level of fibre dosage and the water–cement ratio on the physical properties of hybrid fibre-reinforced concrete (HFRC). Two types of fibres were studied in terms of their effect on the properties of HFRC. The results indicated that the mechanical properties of concrete were significantly improved by increasing the fibre content. However, increasing the percentage fibre content past a certain peak performance limit (0.9% glass fibre (GF) and 0.45% polypropylene fibre (PPF)) led to a decrease in strength compared to reference mixes. Additionally, the incorporation of hybrid fibres yielded an increase in air permeability in the tested specimens. The results showed that the strength-related properties of HFRC were superior to the properties of single fibre-reinforced concrete.


Sign in / Sign up

Export Citation Format

Share Document