scholarly journals Strain-Insensitive Elastic Surface Electromyographic (sEMG) Electrode for Efficient Recognition of Exercise Intensities

Micromachines ◽  
2020 ◽  
Vol 11 (3) ◽  
pp. 239
Author(s):  
Daxiu Tang ◽  
Zhe Yu ◽  
Yong He ◽  
Waqas Asghar ◽  
Ya-Nan Zheng ◽  
...  

Surface electromyography (sEMG) sensors are widely used in the fields of ergonomics, sports science, and medical research. However, current sEMG sensors cannot recognize the various exercise intensities efficiently because of the strain interference, low conductivity, and poor skin-conformability of their electrodes. Here, we present a highly conductive, strain-insensitive, and low electrode–skin impedance elastic sEMG electrode, which consists of a three-layered structure (polydimethylsiloxane/galinstan + polydimethylsiloxane/silver-coated nickel + polydimethylsiloxane). The bottom layer of the electrode consists of vertically conductive magnetic particle paths, which are insensitive to stretching strain, collect sEMG charge from human skin, and finally transfer it to processing circuits via an intermediate layer. Our skin-friendly electrode exhibits high conductivity (0.237 and 1.635 mΩ·cm resistivities in transverse and longitudinal directions, respectively), low electrode–skin impedance (47.23 kΩ at 150 Hz), excellent strain-insensitivity (10% change of electrode–skin impedance within the 0–25% strain range), high fatigue resistance (>1500 cycles), and good conformability with skin. During various exercise intensities, the signal-to-noise ratio (SNR) of our electrode increased by 22.53 dB, which is 206% and 330% more than that of traditional Ag/AgCl and copper electrode, respectively. The ability of our electrode to efficiently recognize various exercise intensities confirms its great application potential for the field of sports health.

Micromachines ◽  
2021 ◽  
Vol 12 (2) ◽  
pp. 218
Author(s):  
Taili Du ◽  
Xusheng Zuo ◽  
Fangyang Dong ◽  
Shunqi Li ◽  
Anaeli Elibariki Mtui ◽  
...  

With the development of intelligent ship, types of advanced sensors are in great demand for monitoring the work conditions of ship machinery. In the present work, a self-powered and highly accurate vibration sensor based on bouncing-ball triboelectric nanogenerator (BB-TENG) is proposed and investigated. The BB-TENG sensor consists of two copper electrode layers and one 3D-printed frame filled with polytetrafluoroethylene (PTFE) balls. When the sensor is installed on a vibration exciter, the PTFE balls will continuously bounce between the two electrodes, generating a periodically fluctuating electrical signals whose frequency can be easily measured through fast Fourier transform. Experiments have demonstrated that the BB-TENG sensor has a high signal-to-noise ratio of 34.5 dB with mean error less than 0.05% at the vibration frequency of 10 Hz to 50 Hz which covers the most vibration range of the machinery on ship. In addition, the BB-TENG can power 30 LEDs and a temperature sensor by converting vibration energy into electricity. Therefore, the BB-TENG sensor can be utilized as a self-powered and highly accurate vibration sensor for condition monitoring of intelligent ship machinery.


Sensors ◽  
2021 ◽  
Vol 21 (16) ◽  
pp. 5621
Author(s):  
Gozde Goncu-Berk ◽  
Bilge Guvenc Tuna

When e-textile EMG electrodes are integrated into clothing, the fit of the clothing on the body, and therefore its pattern and cut become important factors affecting the EMG signal quality in relation to the seamless contact between the skin and the e-textile electrode. The research so far on these effects was conducted on commercially available clothing or in tubular sleeve forms for arms. There is no study that investigated different clothing pattern and fit conditions and their effect on e-textile EMG electrode performance. This study investigates the effect of clothing pattern and fit in EMG applications using e-textile electrodes integrated onto the sleeves of custom drafted t-shirts in set-in and raglan sleeve pattern variations. E-textile electrode resistance, signal-to-noise ratio (SNRdB), power spectral density and electrode–skin impedance are measured and evaluated in set-in sleeve and raglan sleeve conditions with participants during a standardized arm movement protocol in comparison to the conventional hydrogel Ag/AgCl electrodes. The raglan sleeve pattern, widely used in athletic wear to provide extra ease for the movement of the shoulder joint, showed superior performance and therefore indicated the pattern and cut of a garment could have significant effect on EMG signal quality in designing smart clothing.


1998 ◽  
Vol 201 (14) ◽  
pp. 2115-2128 ◽  
Author(s):  
A A Caputi ◽  
R Budelli ◽  
K Grant ◽  
C C Bell

The present study describes a measurement-based model of electric image generation in the weakly electric mormyrid fish Gnathonemus petersii. Measurements of skin impedance, internal resistivity and fish body dimensions have been used to generate an electrical-equivalent model of the fish and to calculate electrical images and equivalent dipole sources for elementary resistive objects. These calculations allow us to understand how exafferent and reafferent signals are sensed by electroreceptors. An object's electric image consists of the modulation of the transcutaneous voltage profile generated by the fish's own discharge. The results suggest a set of rules for electrolocation: (1) the side of the fish where modulation is larger indicates the side on which the object is situated; (2) the object's position in the electroreceptive field is indicated by the point of maximum modulation of the transcutaneous voltage; (3) the degree of focus of the image indicates the distance to the object. In addition, center-surround opposition originating at pre-receptor level is proposed. Both experimental measurements and modeling indicate that fish skin impedance is relatively low (400-11 000 <IMG src="/images/symbols/capomega.gif" WIDTH="13" HEIGHT="13" ALIGN="BOTTOM" NATURALSIZEFLAG="3">cm<SUP>2</SUP>) and mainly resistive. This low skin impedance appears to enhance the local electric organ discharge modulation, the center-surround effect, the signal-to-noise ratio for electrolocation and the active space for electrocommunication.


Author(s):  
Aaisha Diaa-Aldeen Abdullah ◽  
Auns Q. Al-Neami

Traditional wet silver/silver chloride electrodes are used to record electroencephalography (EEG) signals mainly because of their potential repeatability, excellent signal to noise ratio and biocompatibility. This type of electrode is only suitable for conductive glue, which can irritate the skin and cause injury. In addition, as time goes the conductive gel will be dehydrated so the quality of the EEG signal will decrease. To overcome these problems, 3D printed dry-contact electrodes with multi-pins are designed in this work to measure brain signals without prior preparation or gel application. 3D printed electrodes are made from polylactic acids polymer and coated with suitable materials to enhance the conductivity. Electrode-scalp impedance on human was also measured. To evaluate the dry-contact electrode, EEG measurement are performed in subjects and compared with EEG signals acquired by wet electrode by using linear correlation coefficient. Experimentally results showed that the average electrode-skin impedance change of dry electrode in frontal site (9.42-7.25KΩ) and in occipital site (9.56-8.66KΩ). The correlation coefficient between dry and wet electrodes in frontal site (91.4%) and in occipital site (80%). To conclude, the 3D printed dry-contact electrode can be will promising applied on hairy site and provide a promising solutions for long-term monitoring EEG.


2020 ◽  
Vol 12 (24) ◽  
pp. 4014
Author(s):  
Yu Li ◽  
Yun Yang ◽  
Quanhua Zhao

An urban riverway extraction method is proposed for high-resolution synthetic aperture radar (SAR) images. First, the original image is partitioned into overlapping sub-image blocks, in which the sub-image blocks that do not cover riverways are regarded as background. Sub-image blocks covering riverways are then filtered using the iterative adaptive speckle reduction anisotropic diffusion (SRAD) that introduces the relative signal-to-noise ratio (RSNR). The filtered images are segmented quickly by the Sauvola algorithm, and the false riverway fragments are removed by the area and aspect ratio of the connected component in the segmentation results. Using the minimum convex hull of each riverway segment as the connection object, the seeds are automatically determined by the difference between adjacent pyramid layers, and the sub-image block riverway extraction result is used as the bottom layer. The discontinuity connection between river segments is achieved by multi-layer region growth. Finally, the processed sub-image blocks are stitched to get the riverway extraction results for the entire image. To verify the applicability and usefulness of the proposed approach, high-resolution SAR imagery obtained by the Gaofen-3 (GF-3) satellite was used in the assessment. The qualitative and quantitative evaluations of the experimental results show that the proposed method can effectively and completely extract complex urban riverways from high-resolution SAR images.


Author(s):  
W.R. Bottoms ◽  
G.B. Haydon

There is great interest in improving the brightness of electron sources and therefore the ability of electron optical instrumentation to probe the properties of materials. Extensive work by Dr. Crew and others has provided extremely high brightness sources for certain kinds of analytical problems but which pose serious difficulties in other problems. These sources cannot survive in conventional system vacuums. If one wishes to gather information from the other signal channels activated by electron beam bombardment it is necessary to provide sufficient current to allow an acceptable signal-to-noise ratio. It is possible through careful design to provide a high brightness field emission source which has the capability of providing high currents as well as high current densities to a specimen. In this paper we describe an electrode to provide long-lived stable current in field emission sources.The source geometry was based upon the results of extensive computer modeling. The design attempted to maximize the total current available at a specimen.


Author(s):  
David A. Grano ◽  
Kenneth H. Downing

The retrieval of high-resolution information from images of biological crystals depends, in part, on the use of the correct photographic emulsion. We have been investigating the information transfer properties of twelve emulsions with a view toward 1) characterizing the emulsions by a few, measurable quantities, and 2) identifying the “best” emulsion of those we have studied for use in any given experimental situation. Because our interests lie in the examination of crystalline specimens, we've chosen to evaluate an emulsion's signal-to-noise ratio (SNR) as a function of spatial frequency and use this as our critereon for determining the best emulsion.The signal-to-noise ratio in frequency space depends on several factors. First, the signal depends on the speed of the emulsion and its modulation transfer function (MTF). By procedures outlined in, MTF's have been found for all the emulsions tested and can be fit by an analytic expression 1/(1+(S/S0)2). Figure 1 shows the experimental data and fitted curve for an emulsion with a better than average MTF. A single parameter, the spatial frequency at which the transfer falls to 50% (S0), characterizes this curve.


Author(s):  
M. G. R. Thomson

The variation of contrast and signal to noise ratio with change in detector solid angle in the high resolution scanning transmission electron microscope was discussed in an earlier paper. In that paper the conclusions were that the most favourable conditions for the imaging of isolated single heavy atoms were, using the notation in figure 1, either bright field phase contrast with β0⋍0.5 α0, or dark field with an annular detector subtending an angle between ao and effectively π/2.The microscope is represented simply by the model illustrated in figure 1, and the objective lens is characterised by its coefficient of spherical aberration Cs. All the results for the Scanning Transmission Electron Microscope (STEM) may with care be applied to the Conventional Electron Microscope (CEM). The object atom is represented as detailed in reference 2, except that ϕ(θ) is taken to be the constant ϕ(0) to simplify the integration. This is reasonable for θ ≤ 0.1 θ0, where 60 is the screening angle.


Author(s):  
R.D. Leapman ◽  
K.E. Gorlen ◽  
C.R. Swyt

The determination of elemental distributions by electron energy loss spectroscopy necessitates removal of the non-characteristic spectral background from a core-edge at each point in the image. In the scanning transmission electron microscope this is made possible by computer controlled data acquisition. Data may be processed by fitting the pre-edge counts, at two or more channels, to an inverse power law, AE-r, where A and r are parameters and E is energy loss. Processing may be performed in real-time so a single number is saved at each pixel. Detailed analysis, shows that the largest contribution to noise comes from statistical error in the least squares fit to the background. If the background shape remains constant over the entire image, the signal-to-noise ratio can be improved by fitting only one parameter. Such an assumption is generally implicit in subtraction of the “reference image” in energy selected micrographs recorded in the CTEM with a Castaing-Henry spectrometer.


Author(s):  
M. Iwatsuki ◽  
Y. Kokubo ◽  
Y. Harada

On accout of its high brightness, small optical source size, and minimal energy spread, the field emission gun (FEG) has the advantage that it provides the conventional transmission electron microscope (TEM) with a highly coherent illumination system and directly improves the resolving power and signal-to-noise ratio of the scanning electron microscope (SEM). The FEG is generally classified into two types; the cold field emission (C-FEG) and thermal field emission gun (T-FEG). The former, in which a field emitter is used at the room temperature, was successfully developed as an electron source for the SEM. The latter, in which the emitter is heated to the temperature range of 1000-1800°K, was also proved to be very suited as an electron source for the TEM, as well as for the SEM. Some characteristics of the two types of the FEG have been studied and reported by many authors. However, the results of the respective types have been obtained separately under different experimental conditions.


Sign in / Sign up

Export Citation Format

Share Document