scholarly journals Nanoplasmonic Strip Test for Salivary Glucose Monitoring

Nanomaterials ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 105
Author(s):  
Helena Torné-Morató ◽  
Paolo Donati ◽  
Pier Paolo Pompa

Nowadays, there is an increasing interest in Point-of-care (POC) devices for the noninvasive glucose assessment. Despite the recent progress in glucose self-monitoring, commercially available devices still use invasive samples such as blood or interstitial fluids, and they are not equipment-free and affordable for the whole population. Here, we report a fully integrated strip test for the semi-quantitative detection of glucose in whole saliva. The colorimetric mechanism consists of an enzyme-mediated reshaping of multibranched gold nanoparticles (MGNPs) into nanospheres with an associated plasmonic shift and consequent blue-to-red color change, clearly detectable in less than 10 min.

Biosensors ◽  
2019 ◽  
Vol 9 (2) ◽  
pp. 73 ◽  
Author(s):  
Vikram Surendran ◽  
Thomas Chiulli ◽  
Swetha Manoharan ◽  
Stephen Knisley ◽  
Muthukumaran Packirisamy ◽  
...  

The integration of microfluidics with advanced biosensor technologies offers tremendous advantages such as smaller sample volume requirement and precise handling of samples and reagents, for developing affordable point-of-care testing methodologies that could be used in hospitals for monitoring patients. However, the success and popularity of point-of-care diagnosis lies with the generation of instantaneous and reliable results through in situ tests conducted in a painless, non-invasive manner. This work presents the development of a simple, hybrid integrated optical microfluidic biosensor for rapid detection of analytes in test samples. The proposed biosensor works on the principle of colorimetric optical absorption, wherein samples mixed with suitable chromogenic substrates induce a color change dependent upon the analyte concentration that could then be detected by the absorbance of light in its path length. This optical detection scheme has been hybrid integrated with an acoustofluidic micromixing unit to enable uniform mixing of fluids within the device. As a proof-of-concept, we have demonstrated the real-time application of our biosensor format for the detection of potassium in whole saliva samples. The results show that our lab-on-a-chip technology could provide a useful strategy in biomedical diagnoses for rapid analyte detection towards clinical point-of-care testing applications.


2020 ◽  
Vol 49 (6) ◽  
pp. 1812-1866 ◽  
Author(s):  
Sajal Shrivastava ◽  
Tran Quang Trung ◽  
Nae-Eung Lee

POCT systems have been developed toward new form factors as wearable and mobile POCT. New advancements in these POCT systems may provide self-testing capability for on-the-spot diagnosis and monitoring to facilitate rapid treatment decisions.


2021 ◽  
Vol 27 (Supplement_1) ◽  
pp. S57-S57
Author(s):  
Edgar Ong ◽  
Ruo Huang ◽  
Richard Kirkland ◽  
Michael Hale ◽  
Larry Mimms

Abstract Introduction A fast (<5 min), time-resolved fluorescence resonance energy transfer (FRET)-based immunoassay was developed for the quantitative detection of infliximab (IFX) and biosimilars for use in therapeutic drug monitoring using only 20 µL of fingerstick whole blood or serum at the point-of-care. The Procise IFX assay and ProciseDx analyzer are CE-marked. Studies were performed to characterize analytical performance of the Procise IFX assay on the ProciseDx analyzer. Methods Analytical testing was performed by spiking known amounts of IFX into negative serum and whole blood specimens. Analytical sensitivity was determined using limiting concentrations of IFX. Linearity was determined by testing IFX across the assay range. Hook effect was assessed at IFX concentrations beyond levels expected to be found within a patient. Testing of assay precision, cross-reactivity and potential interfering substances, and biosimilars was performed. The Procise IFX assay was also compared head-to-head with another CE-marked assay: LISA-TRACKER infliximab ELISA test (Theradiag, France). The accuracy of the Procise IFX assay is established through calibrators and controls traceable to the WHO 1st International Standard for Infliximab (NIBSC code: 16/170). Results The Procise IFX assay shows a Limit of Blank, Limit of Detection, and Lower Limit of Quantitation (LLoQ) of 0.1, 0.2, and 1.1 µg/mL in serum and 0.6, 1.1, and 1.7 µg/mL in whole blood, respectively. The linear assay range was determined to be 1.7 to 77.2 µg/mL in serum and whole blood. No hook effect was observed at an IFX concentration of 200 µg/mL as the value reported as “>ULoQ”. Assay precision testing across 20 days with multiple runs and reagent lots showed an intra-assay coefficient of variation (CV) of 2.7%, an inter-assay CV of <2%, and a total CV of 3.4%. The presence of potentially interfering/cross-reacting substances showed minimal impact on assay specificity with %bias within ±8% of control. Testing of biosimilars (infliximab-dyyb and infliximab-abda) showed good recovery. A good correlation to the Theradiag infliximab ELISA was obtained for both serum (slope=1.01; r=0.99) and whole blood (slope=1.01; r=0.98) samples (Figure 1). Conclusion Results indicate that the Procise IFX assay is sensitive, specific, and precise yielding results within 5 minutes from both whole blood and serum without the operator needing to specify sample type. Additionally, it shows very good correlation to a comparator assay that takes several hours and sample manipulation to yield results. This makes the Procise IFX assay ideal for obtaining fast and accurate IFX quantitation, thus allowing for immediate drug level dosing decisions to be made by the physician during patient treatment.


2013 ◽  
Vol 7 (06) ◽  
pp. 484-488 ◽  
Author(s):  
Mugundu Ramien Parthasarathy ◽  
Prakash Narayanan ◽  
Anjana Das ◽  
Anup Gurung ◽  
Parimi Prabhakar ◽  
...  

Introduction: Documented experiences from India on the implementation of syphilis screening in large-scale HIV prevention programs for “key populations at higher risk’ (KPs) are limited. Avahan is a large-scale HIV prevention program providing services to more than 300,000 KPs in six high HIV prevalence states of India since 2004. Avahan clinics provide a sexually transmitted infection service package which includes bi-annual syphilis screening. The trends in the coverage of syphilis screening among Avahan clinic attendees were studied retrospectively. Methodology: Screening was performed using either the Rapid Plasma Reagin (RPR) test or point-of-care immunochromatographic strip test (ICST). Clinic records from 2005 to 2009 were collated in an individual tracking database and analyzed with STATA-10. Results: Initially the coverage of syphilis screening (2.6% in 2005) was constrained by the availability and operational complexity of the RPR test. After its introduction in 2007, the use of ICST for screening increased from 7.4% to 77.0% and the proportion of clinic attendees screened increased from 9.0% to 21.6% during 2007-2009. The RPR reactivity rates declined from 6.6% (2006) to 4.4% (2009). Conclusion: The data showed improved rates of screening of clinic attendees and declining trends in sero-reactivity over time. The introduction of point-of-care syphilis tests may have contributed to the improved coverage of syphilis screening. The ICST may be considered for initial syphilis screening at other resource-constrained primary care sites in India such as ante-natal clinics and other KP interventions.


2021 ◽  
Vol 8 (7) ◽  
pp. 98
Author(s):  
Ernst Emmanuel Etienne ◽  
Bharath Babu Nunna ◽  
Niladri Talukder ◽  
Yudong Wang ◽  
Eon Soo Lee

COVID-19, also known as SARS-CoV-2 is a novel, respiratory virus currently plaguing humanity. Genetically, at its core, it is a single-strand positive-sense RNA virus. It is a beta-type Coronavirus and is distinct in its structure and binding mechanism compared to other types of coronaviruses. Testing for the virus remains a challenge due to the small market available for at-home detection. Currently, there are three main types of tests for biomarker detection: viral, antigen and antibody. Reverse Transcription-Polymerase Chain Reaction (RT-PCR) remains the gold standard for viral testing. However, the lack of quantitative detection and turnaround time for results are drawbacks. This manuscript focuses on recent advances in COVID-19 detection that have lower limits of detection and faster response times than RT-PCR testing. The advancements in sensing platforms have amplified the detection levels and provided real-time results for SARS-CoV-2 spike protein detection with limits as low as 1 fg/mL in the Graphene Field Effect Transistor (FET) sensor. Additionally, using multiple biomarkers, detection levels can achieve a specificity and sensitivity level comparable to that of PCR testing. Proper biomarker selection coupled with nano sensing detection platforms are key in the widespread use of Point of Care (POC) diagnosis in COVID-19 detection.


2021 ◽  
Vol 27 (1) ◽  
Author(s):  
Bruna de Oliveira Coelho ◽  
Heloisa Bruna Soligo Sanchuki ◽  
Dalila Luciola Zanette ◽  
Jeanine Marie Nardin ◽  
Hugo Manuel Paz Morales ◽  
...  

Abstract Background SARS-CoV-2 Reverse Transcription Loop-mediated Isothermal Amplification (RT-LAMP) colorimetric detection is a sensitive and specific point-of-care molecular biology technique used to detect the virus in only 30 min. In this manuscript we have described a few nuances of the technique still not properly described in the literature: the presence of three colors clusters; the correlation of the viral load with the color change; and the importance of using an internal control to avoid false-negative results. Methods To achieve these findings, we performed colorimetric RT-LAMP assays of 466 SARS-CoV-2 RT-qPCR validated clinical samples, with color quantification measured at 434 nm and 560 nm. Results First we determinate a sensitivity of 93.8% and specificity of 90.4%. In addition to the pink (negative) and yellow (positive) produced colors, we report for the first time the presence of an orange color cluster that may lead to wrong diagnosis. We also demonstrated using RT-qPCR and RT-LAMP that low viral loads are related to Ct values > 30, resulting in orange colors. We also demonstrated that the diagnosis of COVID-19 by colorimetric RT-LAMP is efficient until the fifth symptoms day when the viral load is still relatively high. Conclusion This study reports properties and indications for colorimetric RT-LAMP as point-of-care for SARS-CoV-2 diagnostic, reducing false results, interpretations and optimizing molecular diagnostics tests application.


BMJ Open ◽  
2021 ◽  
Vol 11 (1) ◽  
pp. e040648
Author(s):  
Nanna Lind ◽  
Dorte Lindqvist Hansen ◽  
Signe Sætre Rasmussen ◽  
Kirsten Nørgaard

IntroductionMedical treatment options for type 2 diabetes (T2D) have increased over the last decade and enhance the possibility of individualised treatment strategies where insulin is still one of them. In spite of the advancements in treatment options, less than one-third of the population with T2D obtain their optimal glycaemic goal. In persons with type 1 diabetes, continuous glucose monitoring (CGM) has shown to be the most important driver for improvement in glycaemic control, even more than insulin-pump therapy. The use of technology in T2D has only been investigated in few studies.The overall objective of the research study is to examine the effectiveness of the use of CGM versus self-monitoring of blood glucose (SMBG) in persons with insulin-treated T2D on glycaemic variables and patient-reported outcomes on treatment satisfaction, health behaviour and well-being. The independent effect of peer support will also be studied.Methods and analysisThe study is a single centre, prospective, randomised, open-labelled, three-armed study with the randomisation 2:1:2 in group A with CGM, group B with CGM and peer support, and group C as a control group with SMBG. The participants receive a training course unique for the allocation group. The study runs for 12 months and includes 100 adult participants with insulin-treated T2D, treated at the outpatient clinic at Steno Diabetes Center Copenhagen. Primary outcome is difference in change in time in range. Recruitment begins in August 2020 and ends in July 2021. Final 12-month follow-up is anticipated to be in August 2022.Ethics and disseminationThe study will be carried out in accordance with the Helsinki Declaration and is approved by the Scientific Ethics Committee of the Capital Region (H-20000843). Data collection and handling will be performed in accordance with the General Data Protection Regulation and is approved by the Danish Data Protection Agency (J-2020-100). Dissemination will be in international peer-reviewed journals, conferences and a plain-language summary for participants.Trial registration numberClinicalTrials.gov Registry (NCT04331444).Protocol versionV.3, 11 December 2020.


2018 ◽  
Vol 12 (2) ◽  
pp. 273-281 ◽  
Author(s):  
Roberto Visentin ◽  
Enrique Campos-Náñez ◽  
Michele Schiavon ◽  
Dayu Lv ◽  
Martina Vettoretti ◽  
...  

Background: A new version of the UVA/Padova Type 1 Diabetes (T1D) Simulator is presented which provides a more realistic testing scenario. The upgrades to the previous simulator, which was accepted by the Food and Drug Administration in 2013, are described. Method: Intraday variability of insulin sensitivity (SI) has been modeled, based on clinical T1D data, accounting for both intra- and intersubject variability of daily SI. Thus, time-varying distributions of both subject’s basal insulin infusion and insulin-to-carbohydrate ratio were calculated and made available to the user. A model of “dawn” phenomenon based on clinical T1D data has been also included. Moreover, the model of subcutaneous insulin delivery has been updated with a recently developed model of commercially available fast-acting insulin analogs. Models of both intradermal and inhaled insulin pharmacokinetics have been included. Finally, new models of error affecting continuous glucose monitoring and self-monitoring of blood glucose devices have been added. Results: One hundred in silico adults, adolescent, and children have been generated according to the above modifications. The new simulator reproduces the intraday glucose variability observed in clinical data, also describing the nocturnal glucose increase, and the simulated insulin profiles reflect real life data. Conclusions: The new modifications introduced in the T1D simulator allow to extend its domain of validity from “single-meal” to “single-day” scenarios, thus enabling a more realistic framework for in silico testing of advanced diabetes technologies including glucose sensors, new insulin molecules and artificial pancreas.


Sign in / Sign up

Export Citation Format

Share Document