scholarly journals Dimensional Changes of Tracheids during Drying of Radiata Pine (Pinus radiata D. Don) Compression Woods: A Study Using Variable-Pressure Scanning Electron Microscopy (VP-SEM)

Plants ◽  
2018 ◽  
Vol 7 (1) ◽  
pp. 14 ◽  
Author(s):  
Miao Zhang ◽  
Bronwen Smith ◽  
Brian McArdle ◽  
Ramesh Chavan ◽  
Bryony James ◽  
...  
Author(s):  
M. Yamada ◽  
K. Ueda ◽  
K. Kuboki ◽  
H. Matsushima ◽  
S. Joens

Use of variable Pressure SEMs is spreading among electron microscopists The variable Pressure SEM does not necessarily require specimen Preparation such as fixation, dehydration, coating, etc which have been required for conventional scanning electron microscopy. The variable Pressure SEM allows operating Pressure of 1˜270 Pa in specimen chamber It does not allow microscopy of water-containing specimens under a saturated vapor Pressure of water. Therefore, it may cause shrink or deformation of water-containing soft specimens such as plant cells due to evaporation of water. A solution to this Problem is to lower the specimen temperature and maintain saturated vapor Pressures of water at low as shown in Fig. 1 On this technique, there is a Published report of experiment to have sufficient signal to noise ratio for scondary electron imaging at a relatively long working distance using an environmental SEM. We report here a new low temperature microscopy of soft Plant cells using a variable Pressure SEM (Hitachi S-225ON).


Author(s):  
Alan Beckett

Low temperature scanning electron microscopy (LTSEM) has been evaluated with special reference to its application to the study of morphology and development in microorganisms. A number of criteria have been considered and have proved valuable in assessing the standard of results achieved. To further aid our understanding of these results, it has been necessary to compare those obtained by LTSEM with those from more conventional preparatory procedures such as 1) chemical fixation, dehydration and critical point-drying; 2) freeze-drying with or without chemical vapour fixation before hand.The criteria used for assessing LTSEM for the above purposes are as follows: 1)Specimen immobilization and stabilization2)General preservation of external morphology3)General preservation of internal morphology4)Exposure to solvents5)Overall dimensional changes6)Cell surface texture7)Differential conformational changes8)Etching frozen-hydrated material9)Beam damage10)Specimen resolution11)Specimen life


Biology ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 51
Author(s):  
Michela Relucenti ◽  
Giuseppe Familiari ◽  
Orlando Donfrancesco ◽  
Maurizio Taurino ◽  
Xiaobo Li ◽  
...  

Several imaging methodologies have been used in biofilm studies, contributing to deepening the knowledge on their structure. This review illustrates the most widely used microscopy techniques in biofilm investigations, focusing on traditional and innovative scanning electron microscopy techniques such as scanning electron microscopy (SEM), variable pressure SEM (VP-SEM), environmental SEM (ESEM), and the more recent ambiental SEM (ASEM), ending with the cutting edge Cryo-SEM and focused ion beam SEM (FIB SEM), highlighting the pros and cons of several methods with particular emphasis on conventional SEM and VP-SEM. As each technique has its own advantages and disadvantages, the choice of the most appropriate method must be done carefully, based on the specific aim of the study. The evaluation of the drug effects on biofilm requires imaging methods that show the most detailed ultrastructural features of the biofilm. In this kind of research, the use of scanning electron microscopy with customized protocols such as osmium tetroxide (OsO4), ruthenium red (RR), tannic acid (TA) staining, and ionic liquid (IL) treatment is unrivalled for its image quality, magnification, resolution, minimal sample loss, and actual sample structure preservation. The combined use of innovative SEM protocols and 3-D image analysis software will allow for quantitative data from SEM images to be extracted; in this way, data from images of samples that have undergone different antibiofilm treatments can be compared.


2019 ◽  
Vol 105 (5) ◽  
pp. 404-410 ◽  
Author(s):  
Federica Grosso ◽  
Alessandro Croce ◽  
Roberta Libener ◽  
Narciso Mariani ◽  
Massimo Pastormerlo ◽  
...  

Purpose: To assess whether asbestos fibers may be observed in liver tissue of patients with cholangiocarcinoma (CC) with environmental or working asbestos exposure. Methods: Detection of fibers was performed directly on histologic sections of liver from 7 patients with CC using optical microscope and variable pressure scanning electron microscopy equipped with energy-dispersive spectroscopy (VP-SEM/EDS). All patients were from Casale Monferrato, Italy, a highly asbestos-polluted town. Due to ethical constraints, observers were blinded to patients’ clinical features. Results: Fibers/bundles of fibers of chrysotile were detected in 5 out of 7 patients (71%). The boundary between healthy and neoplastic tissue or the fibrocollagen tissue produced by the neoplasia were identified as areas of fiber incorporation. Conclusions: This study is the first report about the detection of chrysotile asbestos fibers in the liver of patients with CC. Further studies on larger cohorts are needed to corroborate our preliminary findings.


2009 ◽  
Vol 46 (1) ◽  
pp. 9-14 ◽  
Author(s):  
Andrew D. Haddow ◽  
John K. Moulton ◽  
Reid R. Gerhardt ◽  
Linda J. McCuiston ◽  
Carl J. Jones

Sign in / Sign up

Export Citation Format

Share Document