Asbestos fiber identification in liver from cholangiocarcinoma patients living in an asbestos polluted area: a preliminary study

2019 ◽  
Vol 105 (5) ◽  
pp. 404-410 ◽  
Author(s):  
Federica Grosso ◽  
Alessandro Croce ◽  
Roberta Libener ◽  
Narciso Mariani ◽  
Massimo Pastormerlo ◽  
...  

Purpose: To assess whether asbestos fibers may be observed in liver tissue of patients with cholangiocarcinoma (CC) with environmental or working asbestos exposure. Methods: Detection of fibers was performed directly on histologic sections of liver from 7 patients with CC using optical microscope and variable pressure scanning electron microscopy equipped with energy-dispersive spectroscopy (VP-SEM/EDS). All patients were from Casale Monferrato, Italy, a highly asbestos-polluted town. Due to ethical constraints, observers were blinded to patients’ clinical features. Results: Fibers/bundles of fibers of chrysotile were detected in 5 out of 7 patients (71%). The boundary between healthy and neoplastic tissue or the fibrocollagen tissue produced by the neoplasia were identified as areas of fiber incorporation. Conclusions: This study is the first report about the detection of chrysotile asbestos fibers in the liver of patients with CC. Further studies on larger cohorts are needed to corroborate our preliminary findings.

Author(s):  
M. Yamada ◽  
K. Ueda ◽  
K. Kuboki ◽  
H. Matsushima ◽  
S. Joens

Use of variable Pressure SEMs is spreading among electron microscopists The variable Pressure SEM does not necessarily require specimen Preparation such as fixation, dehydration, coating, etc which have been required for conventional scanning electron microscopy. The variable Pressure SEM allows operating Pressure of 1˜270 Pa in specimen chamber It does not allow microscopy of water-containing specimens under a saturated vapor Pressure of water. Therefore, it may cause shrink or deformation of water-containing soft specimens such as plant cells due to evaporation of water. A solution to this Problem is to lower the specimen temperature and maintain saturated vapor Pressures of water at low as shown in Fig. 1 On this technique, there is a Published report of experiment to have sufficient signal to noise ratio for scondary electron imaging at a relatively long working distance using an environmental SEM. We report here a new low temperature microscopy of soft Plant cells using a variable Pressure SEM (Hitachi S-225ON).


Author(s):  
J. R. Millette ◽  
R. S. Brown

The United States Environmental Protection Agency (EPA) has labeled as “friable” those building materials that are likely to readily release fibers. Friable materials when dry, can easily be crumbled, pulverized, or reduced to powder using hand pressure. Other asbestos containing building materials (ACBM) where the asbestos fibers are in a matrix of cement or bituminous or resinous binders are considered non-friable. However, when subjected to sanding, grinding, cutting or other forms of abrasion, these non-friable materials are to be treated as friable asbestos material. There has been a hypothesis that all raw asbestos fibers are encapsulated in solvents and binders and are not released as individual fibers if the material is cut or abraded. Examination of a number of different types of non-friable materials under the SEM show that after cutting or abrasion, tuffs or bundles of fibers are evident on the surfaces of the materials. When these tuffs or bundles are examined, they are shown to contain asbestos fibers which are free from binder material. These free fibers may be released into the air upon further cutting or abrasion.


Biology ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 51
Author(s):  
Michela Relucenti ◽  
Giuseppe Familiari ◽  
Orlando Donfrancesco ◽  
Maurizio Taurino ◽  
Xiaobo Li ◽  
...  

Several imaging methodologies have been used in biofilm studies, contributing to deepening the knowledge on their structure. This review illustrates the most widely used microscopy techniques in biofilm investigations, focusing on traditional and innovative scanning electron microscopy techniques such as scanning electron microscopy (SEM), variable pressure SEM (VP-SEM), environmental SEM (ESEM), and the more recent ambiental SEM (ASEM), ending with the cutting edge Cryo-SEM and focused ion beam SEM (FIB SEM), highlighting the pros and cons of several methods with particular emphasis on conventional SEM and VP-SEM. As each technique has its own advantages and disadvantages, the choice of the most appropriate method must be done carefully, based on the specific aim of the study. The evaluation of the drug effects on biofilm requires imaging methods that show the most detailed ultrastructural features of the biofilm. In this kind of research, the use of scanning electron microscopy with customized protocols such as osmium tetroxide (OsO4), ruthenium red (RR), tannic acid (TA) staining, and ionic liquid (IL) treatment is unrivalled for its image quality, magnification, resolution, minimal sample loss, and actual sample structure preservation. The combined use of innovative SEM protocols and 3-D image analysis software will allow for quantitative data from SEM images to be extracted; in this way, data from images of samples that have undergone different antibiofilm treatments can be compared.


2019 ◽  
Vol 7 (1) ◽  
Author(s):  
Liu Liu ◽  
Decai Gong ◽  
Zhengquan Yao ◽  
Liangjie Xu ◽  
Zhanyun Zhu ◽  
...  

Abstract Historically, sutras played an important role in spreading Buddhist faith and doctrine, and today these remain important records of Buddhist thought and culture. A Mahamayuri Vidyarajni Sutra with polychrome paintings was found inside the cavity on top of the Nanmen Buddhist pagoda, built in the early Tang dynasty (618–627 CE) and located in Anhui Province, China. Textile was found on the preface which is strongly degraded and fragile. Unfortunately, the whole sutra is under severe degradation and is incomplete. Technical analysis based on scientific methods will benefits the conservation of the sutra. Optical microscopy (OM), micro-Raman spectroscopy combined with optical microscope (Raman), scanning electron microscopy in combination with energy dispersive X-ray analysis (SEM–EDS) and Fourier Transform Infrared Spectroscopy (FTIR) were used to characterize the pigment and gilded material, as well as the paper fiber and textile. Pigments such as cinnabar, minium, paratacamite, azurite, lead white were found. Gilded material was identified as gold. A five-heddle warp satin, made of silk, was found as the textile on the preface of the sutra. The sutra’s preface and inner pages were made of paper comprised of bamboo and bark. As a magnificent yet recondite treasure of Buddhism, the sutra was analyzed for a better understanding of the material. A conservation project of the sutra will be scheduled accordingly.


Author(s):  
SadıkAlper Yıldızel

Structural plaster properties of the residence type buildings that were constructed during prerepublic and early republic periods in Demirci were investigated within the scope of this study. Samples taken from the existing structures were dried in laboratory conditions and made ready for micro-structure examination. Proper samples were examined with scanning electron microscopy (SEM) with the sensitivity of 5 nm and a magnification of 20.000 times, and the optical microscope (magnification: 250 x). In the light of obtained results, it has been determined that the microstructure of the composite used in the Demirci county in the preRepublican period and early republic period is similar to the resultant of mixes produced with the modern fiber added composite production technology. It is thought that this study will contribute to the study of the production of the related building materials to be improved in the future within the limits of the district.


2012 ◽  
Vol 562-564 ◽  
pp. 204-207
Author(s):  
Dong Wang ◽  
Hui Qin Li ◽  
Han Yu Zhao

In this study, 45 carbon steel was boronized and borosulphurized at 950°C for 2, 3, 4, 5, 6 and 8 h, respectively. The samples were characterized by scanning electron microscopy, optical microscope, microhardness tester and ring-on-block wear tester. It is found that the surface of borosulphurized samples was dense, compact and relatively smooth; Although the boride layers produced by boro- sulphurizing at 950°C showed a lower microhardness value compared with that produced by boronizing, the wear resistance of the borosulphurized carbon steel is higher than that of boronized sample due to formation of FeS phase in the boride layer.


Sign in / Sign up

Export Citation Format

Share Document