scholarly journals Intellectual Thermoconductometric Unit Based on Aerosol Printed Ceramic MEMS Sensor for the Measurement of Natural Gas Composition

Proceedings ◽  
2018 ◽  
Vol 2 (13) ◽  
pp. 736 ◽  
Author(s):  
Alexey Vasiliev ◽  
Ilia Shakhnovich ◽  
Nikolay Samotaev ◽  
Daniil Anisimov ◽  
Jan Dziuban ◽  
...  

The online control of natural gas quality is important for customers, because for them the important value is calorific value of consumed gas, but not its volume. The application of thermoconductometric sensor gives simple possibility to fabricate imbedded intellectual plug-and-play device for this control. The ceramic MEMS sensor based on a combination of this ceramic LTCC membrane and aerosol jet printed platinum microheater was used as a sensing element of this unit. The electronic unit controlling the sensor was designed to stabilize the temperature of the microheater and to measure power necessary to maintain this temperature at different concentrations of N2and CO2 in natural gas. The application of this unit enables the measurement of admixtures of nitrogen and CO2 with detection limit of about 1 vol. % sufficient for the application in gas meter instruments.

2021 ◽  
Author(s):  
Pan Luo ◽  
Jonathan Harrist ◽  
Rabah Mesdour ◽  
Nathan Stmichel

Abstract Natural gas is sampled or produced throughout the lifespan of a field, including geochemical surface survey, mud gas logging, formation and well testing, and production. Detecting and measuring gas is a common practice in many upstream operations, providing gas composition and isotope data for multiple purposes, such as gas show, petroleum system analysis, fluid characterization, and production monitoring. Onsite gas analysis is usually conducted within a mud gas unit, which is operationally unavailable after drilling. Gas samples need be taken from the field and shipped back to laboratory for gas chromatography and isotope-ratio mass spectrometry analyses. Results take a considerable time and lack the resolution needed to fully characterize the heterogeneity and dynamics of fluids within the reservoir. We are developing and testing advanced sensing technology to move gas composition and isotope analyses to field for near real-time and onsite fluid characterization and monitoring. We have developed a novel QEPAS (quartz-enhanced photoacoustic spectroscopy) sensor system, employing a single interband cascade laser, to measure concentrations of methane (C1), ethane (C2), and propane (C3) in gas phase. The quartz fork detection module, laser driver, and interface are integrated as a small sensing box. The sensor, sample preparation enclosures and a computer are mounted in a rack as a gas analyzer prototype for the bench testing for oil industry application. Software is designed for monitoring sample preparation, collecting data, calibration and continuous reporting sample pressure and concentration data. The sensor achieved an ultimate detection limit of 90 ppb (parts per billion), 7 ppb and 3 ppm (parts per million) for C1, C2, and C3, respectively, for one second integration time. The detection limit for C2 made a record for QEPAS technique, and measuring C3 added a new capability to the technique. However, the linearity of the QEPAS sensing were previously reported in the range of 0 to 1000 ppm, which is mainly for trace gas detection. In the study, the prototype was separately tested on standard C1, C2, and C3 with different concentrations diluted in dry nitrogen (N2). Good linearity was obtained for all single components and the ranges of linearity were expanded to their typical concentrations (per cent, %) in natural gas samples from oil and gas fields. The testing on the C1-C2 mixtures confirms that accurate C1 and C2 concentrations in % level can be achieved by the prototype. The testing results on C1-C2-C3 mixtures demonstrate the capability of simultaneous detection of three hydrocarbon components and the probability to determine their precise concentrations by QEPAS sensing. This advancement of simultaneous measuring C1, C2 and C3 concentrations, with previously demonstrated capability for hydrogen sulfide (H2S) and carbon dioxide (CO2) and potential to analyze carbon isotopes (13C/12C), promotes QEPAS as a prominent optical technology for gas detection and chemical analysis. The capability of measuring multiple gas components and the advantages in small sensor size, high sensitivity, quick analysis, and continuous sensing (monitoring) open the way to use QEPAS technique for in-situ and real-time gas sensing in oil industry. The iterations of QEPAS sensor might be applied in geochemical survey, on-site fluid characterization, time-lapse monitoring of production, and gas linkage detection in the oil industry.


2020 ◽  
Vol 4 (1) ◽  
pp. 1-7
Author(s):  
Made Dirgantara ◽  
Karelius Karelius ◽  
Marselin Devi Ariyanti, Sry Ayu K. Tamba

Abstrak – Biomassa merupakan salah satu energi terbarukan yang sangat mudah ditemui, ramah lingkungan dan cukup ekonomis. Keberadaan biomassa dapat dimaanfaatkan sebagai pengganti bahan bakar fosil, baik itu minyak bumi, gas alam maupun batu bara. Analisi diperlukan sebagai dasar biomassa sebagai energi seperti proksimat dan kalor. Analisis terpenting untuk menilai biomassa sebagai bahan bakar adalah nilai kalori atau higher heating value (HHV). HHV secara eksperimen diukur menggunakan bomb calorimeter, namun pengukuran ini kurang efektif, karena memerlukan waktu serta biaya yang tinggi. Penelitian mengenai prediksi HHV berdasarkan analisis proksimat telah dilakukan sehingga dapat mempermudah dan menghemat biaya yang diperlukan peneliti. Dalam makalah ini dibahas evaluasi persamaan untuk memprediksi HHV berdasarkan analisis proksimat pada biomassa berdasarkan data dari penelitian sebelumnya. Prediksi nilai HHV menggunakan lima persamaan yang dievaluasi dengan 25 data proksimat biomassa dari penelitian sebelumnya, kemudian dibandingkan berdasarkan nilai error untuk mendapatkan prediksi terbaik. Hasil analisis menunjukan, persamaan A terbaik di 7 biomassa, B di 6 biomassa, C di 6 biomassa, D di 5 biomassa dan E di 1 biomassa.Kata kunci: bahan bakar, biomassa, higher heating value, nilai error, proksimat  Abstract – Biomass is a renewable energy that is very easy to find, environmentally friendly, and quite economical. The existence of biomass can be used as a substitute for fossil fuels, both oil, natural gas, and coal. Analyzes are needed as a basis for biomass as energy such as proximate and heat. The most critical analysis to assess biomass as fuel is the calorific value or higher heating value (HHV). HHV is experimentally measured using a bomb calorimeter, but this measurement is less effective because it requires time and high costs. Research on the prediction of HHV based on proximate analysis has been carried out so that it can simplify and save costs needed by researchers. In this paper, the evaluation of equations is discussed to predict HHV based on proximate analysis on biomass-based on data from previous studies. HHV prediction values using five equations were evaluated with 25 proximate biomass data from previous studies, then compared based on error value to get the best predictions. The analysis shows that Equation A predicts best in 7 biomass, B in 6 biomass, C in 6 biomass, D in 5 biomass, and E in 1 biomass. Key words: fuel, biomass, higher heating value, error value, proximate 


2021 ◽  
Vol 143 (3) ◽  
Author(s):  
Serena Romano ◽  
Roberto Meloni ◽  
Giovanni Riccio ◽  
Pier Carlo Nassini ◽  
Antonio Andreini

Abstract This paper addresses the impact of natural gas composition on both the operability and emissions of lean premixed gas turbine combustion system. This is an issue of growing interest due to the challenge for gas turbine manufacturers in developing fuel-flexible combustors capable of operating with variable fuel gases while producing very low emissions at the same time. Natural gas contains primarily methane (CH4) but also notable quantities of higher order hydrocarbons such as ethane (C2H6) can also be present. A deep understanding of natural gas combustion is important to obtain the highest combustion efficiency with minimal environmental impact. For this purpose, Large Eddy Simulations of an annular combustor sector equipped with a partially premixed burner are carried out for two different natural gas compositions with and without including the effect of flame strain rate and heat loss resulting in a more adequate description of flame shape, thermal field, and extinction phenomena. Promising results, in terms of NOx, compared against available experimental data, are obtained including these effects on the flame brush modeling, enhancing the fuel-dependency under nonadiabatic condition.


2019 ◽  
Vol 42 (3) ◽  
pp. 690-698
Author(s):  
Steven Wang ◽  
Woo Jin Lee ◽  
Chao'en Li ◽  
Benny Kuan ◽  
Nick Burke ◽  
...  

2022 ◽  
Vol 13 (1) ◽  
Author(s):  
Xiaoqin Si ◽  
Rui Lu ◽  
Zhitong Zhao ◽  
Xiaofeng Yang ◽  
Feng Wang ◽  
...  

AbstractNatural gas is one of the foremost basic energy sources on earth. Although biological process appears as promising valorization routes to transfer biomass to sustainable methane, the recalcitrance of lignocellulosic biomass is the major limitation for the production of mixing gas to meet the natural gas composition of pipeline transportation. Here we develop a catalytic-drive approach to directly transfer solid biomass to bio-natural gas which can be suitable for the current infrastructure. A catalyst with Ni2Al3 alloy phase enables nearly complete conversion of various agricultural and forestry residues, the total carbon yield of gas products reaches up to 93% after several hours at relative low-temperature (300 degrees Celsius). And the catalyst shows powerful processing capability for the production of natural gas during thirty cycles. A low-carbon footprint is estimated by a preliminary life cycle assessment, especially for the low hydrogen pressure and non-fossil hydrogen, and technical economic analysis predicts that this process is an economically competitive production process.


Author(s):  
K. M. Shynkaruk

In connection with the increase in prices for natural gas, the urgent issue is to calculate not only the amount of gas consumed, but also its quality precisely with the consumer. The quality of gas is the compliance of its physicochemical parameters with established regulatory documents. With the current gas accounting and payment system in Ukraine, consumers using the same number of cubic meters receive different heat of combustion. The paper analyzes the regulatory framework for assessing the energy performance of natural gas. The necessity of the transition to accounting for natural gas in energy units is substantiated. Existing methods and means for determining the calorific value of natural gas that are used in Ukraine and abroad are considered. Currently, direct and indirect methods are used to determine the calorific value of natural value of natural gas. The most common is the calculation method based on chromatographic analysis, the implementation of which requires expensive equipment. Other methods for determining the calorific value of natural gas is correlation. The essence of which is to establish the relationship between a certain physicochemical property of natural gas and calorific value, which can be established by experimental observations and based on theoretical analysis, which makes it possible to draw a conclusion about the calorific value of natural gas. Based on the analysis, it was found that currently there are no simple in design and not expensive means of controlling the qualitative characteristics of natural gas commercially available. Therefore, it is relevant to solve the problem of operational control of the quality of natural gas, through scientific justification, development and improvement of tools that enable the indirect accounting of the energy value of natural gas in accordance with global trends in energy accounting. A correlation analysis was carried out to establish the relationship between the thermal conductivity and the calorific value of natural gas. The use of the thermocatalytic method for determining the calorific value of gas is proposed, which will allow designing a relatively cheap and easy-to-use device for monitoring the quality of natural gas specifically for the consumer.


Sign in / Sign up

Export Citation Format

Share Document