particulate emissions
Recently Published Documents


TOTAL DOCUMENTS

1088
(FIVE YEARS 193)

H-INDEX

56
(FIVE YEARS 9)

Fuel ◽  
2022 ◽  
Vol 312 ◽  
pp. 122965
Author(s):  
Faisal Lodi ◽  
Ali Zare ◽  
Priyanka Arora ◽  
Svetlana Stevanovic ◽  
Zoran D Ristovski ◽  
...  

Fuel ◽  
2022 ◽  
Vol 310 ◽  
pp. 122283
Author(s):  
Siqi Liu ◽  
Guangqing Zhu ◽  
Yanqing Niu ◽  
Liping Wen ◽  
Yu Lei ◽  
...  

Catalysts ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 70
Author(s):  
Barouch Giechaskiel ◽  
Anastasios Melas ◽  
Victor Valverde ◽  
Marcos Otura ◽  
Giorgio Martini

The emission limit of non-volatile particles (i.e., particles that do not evaporate at 350 °C) with size >23 nm, in combination with the real driving emissions (RDE) regulation in 2017, resulted in the introduction of gasoline particulate filters (GPFs) in all light-duty vehicles with gasoline direct injection engines in Europe. Even though there are studies that have examined the particulate emissions at or beyond the current RDE boundary conditions, there is a lack of studies combining most or all worst cases (i.e., conditions that increase the emissions). In this study, we challenged a fresh (i.e., no accumulation of soot or ash) “advanced” prototype GPF at different temperatures (down to −9 °C), aggressive drive cycles and hard accelerations (beyond the RDE limits), high payload (up to 90%), use of all auxiliaries (air conditioning, heating of the seats and the rear window), and cold starts independently or simultaneously. Under hot engine conditions, the increase of the particulate emissions due to higher payload and lower ambient temperature was 30–90%. The cold start at low ambient temperature, however, had an effect on the emissions of up to a factor of 20 for particles >23 nm or 300 when considering particles <23 nm. We proposed that the reason for these high emissions was the incomplete combustion and the low efficiency of the three-way oxidation catalyst. This resulted in a high concentration of species that were in the gaseous phase at the high temperature of the close-coupled GPF and thus could not be filtered by the GPF. As the exhaust gas cooled down, these precursor species formed particles that could not be evaporated at 350 °C (the temperature of the particle number system). These results highlight the importance of the proper calibration of the engine out emissions at all conditions, even when a GPF is installed.


2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Hoseung Yi ◽  
Jihwan Seo ◽  
Young Soo Yu ◽  
Yunsung Lim ◽  
Sanguk Lee ◽  
...  

AbstractGasoline direct injection (GDI) engines emit less carbon dioxide (CO2) than port fuel injection (PFI) engines when fossil fuel conditions are the same. However, GDI engines emit more ultrafine particulate matter, which can have negative health effects, leading to particulate emission regulations. To satisfy these regulations, various studies have been done to reduce particulate matter, and several studies focused on lubricants. This study focuses on the influence of lubricant on the formation of particulate matter and its effect on particulate emissions in GDI engines. An instrumented, combustion and optical singe-cylinder GDI engine fueled by four different lubricant-gasoline blends was used with various injection conditions. Combustion experiments were used to determine combustion characteristics, and gaseous emissions indicated that the lubricant did not influence mixture homogeneity but had an impact on unburned fuels. Optical experiments showed that the lubricant did not influence spray but did influence wall film formation during the injection period, which is a major factor affecting particulate matter generation. Particulate emissions indicated that lubricant included in the wall film significantly affected PN emissions depending on injection conditions. Additionally, the wall film influenced by the lubricant affected the overall particle size and its distribution.


2022 ◽  
Vol 12 (1) ◽  
pp. 445
Author(s):  
Bartosz Wieczorek ◽  
Mateusz Kukla ◽  
Łukasz Warguła

The purpose of this article was to present an algorithm for creating an ellipse for any data set represented on a two-dimensional reference frame. The study objective was to verify the developed method on real results of experimental tests with different subject matter. This article contains a mathematical algorithm to describe a set of points with elliptical areas. In addition, four results of tests with different subject matter are cited, based on which the developed method was verified. The verification of the method included checking the deviation of the geometric dimensions of the ellipse, the number of points contained within the ellipse, and the area of the ellipse. The implemented research methodology allowed to demonstrate the possibility of using the method of describing a set of points with elliptical areas, in order to determine quantitative parameters evaluating the results of the test. The presented results show the method’s applicability for the results obtained in four different operational tests: measurement of the human body’s gravity center position for a person propelling a wheelchair, measurement of marker position using motion capture methods, measurement of particulate emissions when using equipment powered by an internal combustion engine, and measurement of the muscle activity of the upper limb when propelling a hybrid manual-electric wheelchair. The performed experiments demonstrated that the method allows to describe about 85% of all measurement points with an ellipse.


Author(s):  
Bogdan Manolin JURCHIȘ

The aim of this research was to highlight the impact of using different types of fuels on particulate emissions and also on the operation on particulate filters on diesel engines. For all the results obtained from the experimental tests, comparative studies were performed to find the optimal fuel mixture that can be used in order to obtain the optimal performance of the particle filter, without affecting the engine performance. Following the initial tests performed without DPF, the case with the highest smoke emission value (2000 1/min) was identified. For this case, continuous measurement tests were then performed. For this reason, a more detailed analysis was made only for this case.


2021 ◽  
pp. 128124
Author(s):  
Qixia Zhang ◽  
Shuai Liu ◽  
Zhong Wang ◽  
Ruina Li ◽  
Libin Zhang ◽  
...  

Fuel ◽  
2021 ◽  
pp. 122710
Author(s):  
Di Yage ◽  
Zhang Junjie ◽  
Cheung Chun Shun ◽  
Miao Xuelong ◽  
Zheng Jinbao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document