scholarly journals Pléiades Tri-Stereo Data for Glacier Investigations—Examples from the European Alps and the Khumbu Himal

2018 ◽  
Vol 10 (10) ◽  
pp. 1563 ◽  
Author(s):  
Lorenzo Rieg ◽  
Christoph Klug ◽  
Lindsey Nicholson ◽  
Rudolf Sailer

In this study, we use Pléiades tri-stereo data to generate a digital elevation model (DEM) from the Pléiades images using a workflow employing semi-global matching (SGM). We examine the DEM accuracy in complex mountain glaciated terrain by comparing the new DEMs with an independent high-quality DEM based on airborne laser scanning (ALS) data for a study area in the Austrian Alps, and with ground control points for a study area in the Khumbu Himal of Nepal. The DEMs derived using the SGM algorithm compare well to the independent high-quality ALS DEM, and the workflow produces models of sufficient quality to resolve ground control points, which are based on Pléiades imagery that are of sufficient quality to perform high spatio-temporal resolution assessments of remote areas for which no field data is available. The relative accuracy is sufficient to investigate glacier surface elevation changes below one meter, and can therefore be applied over relatively short periods of time, such as those required for annual and seasonal assessments of change. The annual geodetic mass balance for the Alpine case derived from our DEM compares well to the glaciological mass balance, and multitemporal DEM analysis is used to resolve the seasonal changes of five glaciers in the Khumbu Himal, revealing that glaciological processes such as accumulation, ablation, and glacier movement mainly take place during the summer season, with the winter season being largely inactive in the year sampled.

2014 ◽  
Vol 8 (5) ◽  
pp. 4849-4883 ◽  
Author(s):  
E. Berthier ◽  
C. Vincent ◽  
E. Magnússon ◽  
Á. Þ. Gunnlaugsson ◽  
P. Pitte ◽  
...  

Abstract. In response to climate change, most glaciers are losing mass and hence contribute to sea-level rise. Repeated and accurate mapping of their surface topography is required to estimate their mass balance and to extrapolate/calibrate sparse field glaciological measurements. In this study we evaluate the potential of Pléiades sub-meter stereo imagery to derive digital elevation models (DEMs) of glaciers and their elevation changes. Our five validation sites are located in Iceland, the European Alps, the Central Andes, Nepal and Antarctica. For all sites, nearly simultaneous field measurements were collected to evaluate the Pléiades DEMs. For Iceland, the Pléiades DEM is also compared to a Lidar DEM. The vertical biases of the Pléiades DEMs are less than 1 m if ground control points (GCPs) are used, but reach up to 6 m without GCPs. Even without GCPs, vertical biases can be reduced to a few decimetres by horizontal and vertical co-registration of the DEMs to reference altimetric data on ice-free terrain. Around these biases, the vertical precision of the Pléiades DEMs is ±1 m and even ±0.5 m on the flat glacier tongues (1-sigma confidence level). We also demonstrate the high potential of Pléiades DEMs for measuring seasonal, annual and multi-annual elevation changes with an accuracy of 1 m or better. The negative glacier-wide mass balances of the Argentière Glacier and Mer de Glace (−1.21 ± 0.16 and −1.19 ± 0.16 m.w.e. yr−1, respectively) are revealed by differencing SPOT5 and Pléiades DEMs acquired in August 2003 and 2012 demonstrating the continuing rapid glacial wastage in the Mont-Blanc area.


2016 ◽  
Author(s):  
Joaquín M. C. Belart ◽  
Etienne Berthier ◽  
Eyjólfur Magnússon ◽  
Leif S. Anderson ◽  
Finnur Pálsson ◽  
...  

Abstract. Sub-meter resolution satellite stereo images allow the generation of high resolution, accurate digital elevation models (DEMs). Repeated acquisitions of stereo images from Pléiades, in October 2014 and May 2015, and from WorldView2 (WV2), in February 2015, over Drangajökull ice cap (NW-Iceland) are used to estimate the geodetic glacier-wide mass balance on sub-annual time scales. Relative adjustment of the DEMs is performed with and without a pre-existing lidar DEM as source of ground control points (GCPs), and resulting statistics in snow-free and ice-free areas reveal similar vertical accuracy


2014 ◽  
Vol 8 (6) ◽  
pp. 2275-2291 ◽  
Author(s):  
E. Berthier ◽  
C. Vincent ◽  
E. Magnússon ◽  
Á. Þ. Gunnlaugsson ◽  
P. Pitte ◽  
...  

Abstract. In response to climate change, most glaciers are losing mass and hence contribute to sea-level rise. Repeated and accurate mapping of their surface topography is required to estimate their mass balance and to extrapolate/calibrate sparse field glaciological measurements. In this study we evaluate the potential of sub-meter stereo imagery from the recently launched Pléiades satellites to derive digital elevation models (DEMs) of glaciers and their elevation changes. Our five evaluation sites, where nearly simultaneous field measurements were collected, are located in Iceland, the European Alps, the central Andes, Nepal and Antarctica. For Iceland, the Pléiades DEM is also compared to a lidar DEM. The vertical biases of the Pléiades DEMs are less than 1 m if ground control points (GCPs) are used, but reach up to 7 m without GCPs. Even without GCPs, vertical biases can be reduced to a few decimetres by horizontal and vertical co-registration of the DEMs to reference altimetric data on ice-free terrain. Around these biases, the vertical precision of the Pléiades DEMs is ±1 m and even ±0.5 m on the flat glacier tongues (1σ confidence level). Similar precision levels are obtained in the accumulation areas of glaciers and in Antarctica. We also demonstrate the high potential of Pléiades DEMs for measuring seasonal, annual and multi-annual elevation changes with an accuracy of 1 m or better if cloud-free images are available. The negative region-wide mass balances of glaciers in the Mont-Blanc area (−1.04 ± 0.23 m a−1 water equivalent, w.e.) are revealed by differencing Satellite pour l'Observation de la Terre 5 (SPOT 5) and Pléiades DEMs acquired in August 2003 and 2012, confirming the accelerated glacial wastage in the European Alps.


Author(s):  
A. M. G. Tommaselli ◽  
F. M. Torres

Unmanned Aerial Vehicles (UAV) have been recognized as a tool for geospatial data acquisition due to their flexibility and favourable cost benefit ratio. The practical use of laser scanning devices on-board UAVs is also developing with new experimental and commercial systems. This paper describes a light-weight laser scanning system composed of an IbeoLux scanner, an Inertial Navigation System Span-IGM-S1, from Novatel, a Raspberry PI portable computer, which records data from both systems and an octopter UAV. The performance of this light-weight system was assessed both for accuracy and with respect to point density, using Ground Control Points (GCP) as reference. Two flights were performed with the UAV octopter carrying the equipment. In the first trial, the flight height was 100 m with six strips over a parking area. The second trial was carried out over an urban park with some buildings and artificial targets serving as reference Ground Control Points. In this experiment a flight height of 70 m was chosen to improve target response. Accuracy was assessed based on control points the coordinates of which were measured in the field. Results showed that vertical accuracy with this prototype is around 30 cm, which is acceptable for forest applications but this accuracy can be improved using further refinements in direct georeferencing and in the system calibration.


Author(s):  
I. Weber ◽  
A. Jenal ◽  
C. Kneer ◽  
J. Bongartz

Research and monitoring in fields like hydrology and agriculture are applications of airborne thermal infrared (TIR) cameras, which suffer from low spatial resolution and low quality lenses. Common ground control points (GCPs), lacking thermal activity and being relatively small in size, cannot be used in TIR images. Precise georeferencing and mosaicing however is necessary for data analysis. Adding a high resolution visible light camera (VIS) with a high quality lens very close to the TIR camera, in the same stabilized rig, allows us to do accurate geoprocessing with standard GCPs after fusing both images (VIS+TIR) using standard image registration methods.


2016 ◽  
Vol 62 (233) ◽  
pp. 486-496 ◽  
Author(s):  
C. PAPASODORO ◽  
A. ROYER ◽  
A. LANGLOIS ◽  
E. BERTHIER

ABSTRACTThe study of glaciers and ice caps in remote and cloudy regions remains difficult using current remote sensing tools. Here the potential of stereo radargrammetry (SRG) with RADARSAT-2 Wide Ultra-Fine images is explored for DEM extraction, elevation changes and mass-balance calculations on Barnes Ice Cap (Nunavut, Canada). Over low-relief terrain surrounding Barnes, a vertical precision of ~7 m (1σ confidence level) is measured, as well as an average vertical bias of ~4 m. Moreover, we show that the C-band penetration depth over the ice cap is insignificant at this time of the year (i.e. late ablation season). This is likely due to a wet surface and the presence of superimposed ice that leads to a surface radar response. Comparing the SRG DEMs with other datasets, an historical glacier-wide mass balance of −0.52 ± 0.19 m w.e. a−1is estimated for 1960–2013, whereas it decreases to −1.06 ± 0.84 m w.e. a−1between 2005 and 2013. This clear acceleration of mass loss is in agreement with other recent studies. Given its all-weather functionality and its possible use without ground control points, the RADARSAT-2 SRG technology represents an appropriate alternative for glacier monitoring in cloudy and remote regions.


2019 ◽  
Vol 11 (11) ◽  
pp. 1352 ◽  
Author(s):  
Alphonse Nahon ◽  
Pere Molina ◽  
Marta Blázquez ◽  
Jennifer Simeon ◽  
Sylvain Capo ◽  
...  

Recurrent monitoring of sandy beaches and of the dunes behind them is needed to improve the scientific knowledge on their dynamics as well as to develop sustainable management practices of those valuable landforms. Unmanned Aircraft Systems (UAS) are sought as a means to fulfill this need, especially leveraged by photogrammetric and LiDAR-based mapping methods and technology. The present study compares different strategies to carry UAS photogrammetric corridor mapping over linear extensions of sandy shores. In particular, we present results on the coupling of a UAS with a mobile laser scanning system, operating simultaneously in Cap Ferret, SW France. This aerial-terrestrial tandem enables terrain reconstruction with kinematic ground control points, thus largely avoiding the deployment of surveyed ground control points on the non-stable sandy ground. Results show how these three techniques—mobile laser scanning, photogrammetry based on ground control points, and photogrammetry based on kinematic ground control points—deliver accurate (i.e., root mean square errors < 15 cm) 3D reconstruction of beach-to-dune transition areas, the latter being performed at lower survey and logistic costs, and with enhanced spatial coverage capabilities. This study opens the gate for exploring longer (hundreds of kilometers) shoreline dynamics with ground-control-point-free air and ground mapping techniques.


Author(s):  
A. M. G. Tommaselli ◽  
F. M. Torres

Unmanned Aerial Vehicles (UAV) have been recognized as a tool for geospatial data acquisition due to their flexibility and favourable cost benefit ratio. The practical use of laser scanning devices on-board UAVs is also developing with new experimental and commercial systems. This paper describes a light-weight laser scanning system composed of an IbeoLux scanner, an Inertial Navigation System Span-IGM-S1, from Novatel, a Raspberry PI portable computer, which records data from both systems and an octopter UAV. The performance of this light-weight system was assessed both for accuracy and with respect to point density, using Ground Control Points (GCP) as reference. Two flights were performed with the UAV octopter carrying the equipment. In the first trial, the flight height was 100 m with six strips over a parking area. The second trial was carried out over an urban park with some buildings and artificial targets serving as reference Ground Control Points. In this experiment a flight height of 70 m was chosen to improve target response. Accuracy was assessed based on control points the coordinates of which were measured in the field. Results showed that vertical accuracy with this prototype is around 30 cm, which is acceptable for forest applications but this accuracy can be improved using further refinements in direct georeferencing and in the system calibration.


Sign in / Sign up

Export Citation Format

Share Document