scholarly journals River Flow Monitoring by Sentinel-3 OLCI and MODIS: Comparison and Combination

2020 ◽  
Vol 12 (23) ◽  
pp. 3867
Author(s):  
Angelica Tarpanelli ◽  
Filippo Iodice ◽  
Luca Brocca ◽  
Marco Restano ◽  
Jérôme Benveniste

The monitoring of rivers by satellite is an up-to-date subject in hydrological studies as confirmed by the interest of space agencies to finance specific missions that respond to the quantification of surface water flows. We address the problem by using multi-spectral sensors, in the near-infrared (NIR) band, correlating the reflectance ratio between a dry and a wet pixel extracted from a time series of images, the C/M ratio, with five river flow-related variables: water level, river discharge, flow area, mean flow velocity and surface width. The innovative aspect of this study is the use of the Ocean and Land Colour Instrument (OLCI) on board Sentinel-3 satellites, compared to the Moderate Resolution Imaging Spectroradiometer (MODIS) used in previous studies. Our results show that the C/M ratio from OLCI and MODIS is more correlated with the mean flow velocity than with other variables. To improve the number of observations, OLCI and MODIS products are combined into multi-mission time series. The integration provides good quality data at around daily resolution, appropriate for the analysis of the Po River investigated in this study. Finally, the combination of only MODIS products outperforms the other configurations with a frequency slightly lower (~1.8 days).

Author(s):  
Christoph Jörg ◽  
Michael Wagner ◽  
Thomas Sattelmayer

The thermoacoustic stability of gas turbines depends on a balance of acoustic energy inside the engine. While the flames produce acoustic energy, other areas like the impingement cooling system contribute to damping. In this paper, we investigate the damping potential of an annular impingement sleeve geometry embedded into a realistic environment. A cold flow test rig was designed to represent real engine conditions in terms of geometry, and flow situation. High quality data was delivered by six piezoelectric dynamic pressure sensors. Experiments were carried out for different mean flow velocities through the cooling holes. The acoustic reflection coefficient of the impingement sleeve was evaluated at a downstream reference location. Further parameters investigated were the number of cooling holes, and the geometry of the chamber surrounding the impingement sleeve. Experimental results show that the determining parameter for the reflection coefficient is the mean flow velocity through the impingement holes. An increase of the mean flow velocity leads to significantly increased damping, and to low values of the reflection coefficient.


Water ◽  
2020 ◽  
Vol 12 (6) ◽  
pp. 1786
Author(s):  
Jitendra Kumar Vyas ◽  
Muthiah Perumal ◽  
Tommaso Moramarco

Streamflow measurements during high floods is a challenge for which the World Meteorological Organization fosters the development of innovative technologies for achieving an accurate estimation of the discharge. The use of non-contact sensors for monitoring surface flow velocities is of interest to turn these observed values into a cross-sectional mean flow velocity, and subsequently, into discharge if bathymetry is given. In this context, several techniques are available for the estimation of mean flow velocity, starting from observed surface velocities. Among them, the entropy-based methodology for river discharge assessment is often applied by leveraging the theoretical entropic principles of Shannon and Tsallis, both of which link the maximum flow velocity measured at a vertical of the flow area, named the y-axis, and the cross-sectional mean flow velocity at a river site. This study investigates the performance of the two different entropic approaches in estimating the mean flow velocity, starting from the maximum surface flow velocity sampled at the y-axis. A velocity dataset consisting of 70 events of measurements collected at two gauged stations with different geometric and hydraulic characteristics on the Po and Tiber Rivers in Italy was used for the analysis. The comparative evaluation of the velocity distribution observed at the y-axis of all 70 events of measurement was closely reproduced using both the Shannon and Tsallis entropy approaches. Accurate values in terms of the cross-sectional mean flow velocity and discharge were obtained with average errors not exceeding 10%, demonstrating that the Shannon and Tsallis entropy concepts were equally efficient for discharge estimation in any flow conditions.


Stroke ◽  
2017 ◽  
Vol 48 (suppl_1) ◽  
Author(s):  
Christopher G Favilla ◽  
Ashwin B Parthasarathy ◽  
John A Detre ◽  
Michael T Mullen ◽  
Scott E Kasner ◽  
...  

Background: Optimization of cerebral blood flow is the cornerstone of clinical management in a number of neurologic diseases, most notably ischemic stroke. Intra-thoracic pressure influences cardiac output and has the potential to impact cerebral blood flow (CBF). Here we aim to quantify cerebral hemodynamic changes in response to increased respiratory impedance using a non-invasive respiratory device. Methods: Cerebral perfusion was measured under varying levels of respiratory impedance (6cm H 2 0, 9cm H 2 0, and 12 cm H 2 0) in 20 healthy volunteers. Simultaneous measurements of microvascular CBF and middle cerebral artery mean flow velocity (MFV), respectively, were performed with optical diffuse correlation spectroscopy (DCS) and transcranial Doppler ultrasound (TCD). Results: At the high level of respiratory impedance, mean flow velocity increased by 6.4% compared to baseline (p=0.004), but changes in cortical CBF were smaller and non-significant (Figure). Heart rate, cardiac output, respiratory rate, and end tidal CO 2 remained stable during all levels of respiratory impedance. There was small increase in mean arterial blood pressure, 1.7% (p=0.006), at the high level of respiratory impedance. In a multivariable linear regression model accounting for end tidal CO 2 and individual variability, respiratory impedance was associated with increases in both mean flow velocity (coefficient: 0.49, p<0.001) and cortical CBF (coefficient: 0.13, p<0.001). Conclusions: Manipulating intrathoracic pressure via non-invasive respiratory impedance was well tolerated and produced a small but measurable increase in cerebral perfusion in healthy individuals. Future studies in acute ischemic stroke patients with impaired cerebral autoregulation is warranted in order to assess whether respiratory impedance is feasible as a novel non-invasive therapy for stroke.


1994 ◽  
Vol 120 (12) ◽  
pp. 1385-1400 ◽  
Author(s):  
Martin J. Teal ◽  
Robert Ettema ◽  
John F. Walker

Owing to observational difficulties the distinction between a ‘suspended’ load of solids transported by a stream and a ‘ bed-load ’ has long remained undefined. Recently, however, certain critical experiments have thrown much light on the nature of bed-load transport. In particular, it has been shown that bed-load transport, by saltation, occurs in the absence of fluid turbulence and must therefore be due to a separate dynamic process from that of transport in suspension by the internal eddy motion of a turbulent fluid. It has been further shown that the forward motion of saltating solids is opposed by a frictional force of the same order as the immersed weight of the solids, the friction coefficient approximating to that given by the angle of slip. The maintenance of steady motion therefore requires a predictable rate of energy dissipation by the transporting fluid. The fluid thrust necessary to maintain the motion is shown to be exerted by virtue of a mean slip velocity which is predictable in the same way as, and approxim ates to, the terminal fall velocity of the solid. The mean thrust, and therefore the transport rate of saltating solids, are therefore predictable in terms of the fluid velocity close to the bed, at a distance from it, within the saltation zone, of a ‘centre of fluid thrust’ analogous to the ‘centre of pressure’. This velocity, which is not directly measurable in water streams, can be got from a knowledge of stream depth and mean flow velocity. Thus a basic energy equation is obtained relating the rate of transporting work done to available fluid transporting power. This is shown to be applicable to the transport both of wind-blown sand, and of water-driven solids of all sizes and larger than that of medium sand. Though the mean flow velocity is itself unpredictable, the total stream power, which is the product of this quantity times the bed shear stress, is readily measurable. But since the mean flow velocity is an increasing function of flow depth, the transport of solids expressed in terms of total stream power must decrease with increasing flow depth/grain size ratio. This considerable variation with flow depth has not been previously recognised. It explains the gross inconsistencies found in the existing experimental data. The theoretical variation is shown to approximate very closely to that found in recent critical experiments in which transport rates were measured at different constant flow depths. The theory, which is largely confirmed by these and other earlier experiments, indicates that suspension by fluid turbulence of mineral solids larger than those of medium sands does not become appreciable until the bed shear stress is increased to a value exceeding 12 times its threshold value for the bed material considered. This range of unsuspended transport decreases rapidly, however, as the grain size is reduced till, at a certain critical size, suspension should occur at the threshold of bed movement.


2020 ◽  
Vol 17 (5) ◽  
pp. 1221-1236
Author(s):  
Hui-Huang Fang ◽  
Shu-Xun Sang ◽  
Shi-Qi Liu

Abstract The three-dimensional (3D) structures of pores directly affect the CH4 flow. Therefore, it is very important to analyze the 3D spatial structure of pores and to simulate the CH4 flow with the connected pores as the carrier. The result shows that the equivalent radius of pores and throats are 1–16 μm and 1.03–8.9 μm, respectively, and the throat length is 3.28–231.25 μm. The coordination number of pores concentrates around three, and the intersection point between the connectivity function and the X-axis is 3–4 μm, which indicate the macro-pores have good connectivity. During the single-channel flow, the pressure decreases along the direction of CH4 flow, and the flow velocity of CH4 decreases from the pore center to the wall. Under the dual-channel and the multi-channel flows, the pressure also decreases along the CH4 flow direction, while the velocity increases. The mean flow pressure gradually decreases with the increase of the distance from the inlet slice. The change of mean flow pressure is relatively stable in the direction horizontal to the bedding plane, while it is relatively large in the direction perpendicular to the bedding plane. The mean flow velocity in the direction horizontal to the bedding plane (Y-axis) is the largest, followed by that in the direction horizontal to the bedding plane (X-axis), and the mean flow velocity in the direction perpendicular to the bedding plane is the smallest.


2009 ◽  
Vol 111 (1) ◽  
pp. 22-27 ◽  
Author(s):  
Satoshi Tateshima ◽  
Kazuo Tanishita ◽  
Yasuhiro Hakata ◽  
Shin-ya Tanoue ◽  
Fernando Viñuela

Object Development of a flexible self-expanding stent system and stent-assisted coiling technique facilitates endovascular treatment of wide-necked brain aneurysms. The hemodynamic effect of self-expandable stent placement across the neck of a brain aneurysm has not been well documented in patient-specific aneurysm models. Methods Three patient-specific silicone aneurysm models based on clinical images were used in this study. Model 1 was constructed from a wide-necked internal carotid artery–ophthalmic artery aneurysm, and Models 2 and 3 were constructed from small wide-necked middle cerebral artery aneurysms. Neuroform stents were placed in the in vitro aneurysm models, and flow structures were compared before and after the stent placements. Flow velocity fields were acquired with particle imaging velocimetry. Results In Model 1, a clockwise, single-vortex flow pattern was observed in the aneurysm dome before stenting was performed. There were multiple vortices, and a very small fast flow stream was newly formed in the aneurysm dome after stenting. The mean intraaneurysmal flow velocity was reduced by ~ 23–40%. In Model 2, there was a clockwise vortex flow in the aneurysm dome and another small counterclockwise vortex in the tip of the aneurysm dome before stenting. The small vortex area disappeared after stenting, and the mean flow velocity in the aneurysm dome was reduced by 43–64%. In Model 3, a large, counterclockwise, single vortex was seen in the aneurysm dome before stenting. Multiple small vortices appeared in the aneurysm dome after stenting, and the mean flow velocity became slower by 22–51%. Conclusions The flexible self-expandable stents significantly altered flow velocity and also flow structure in these aneurysms. Overall flow alterations by the stent appeared favorable for the long-term durability of aneurysm embolization. The possibility that the placement of a low-profile self-expandable stent might induce unfavorable flow patterns such as a fast flow stream in the aneurysm dome cannot be excluded.


1997 ◽  
Vol 10 (2_suppl) ◽  
pp. 43-45
Author(s):  
M. Santoni ◽  
M. Mascalchi ◽  
M. Cellerini ◽  
A. Cuttano ◽  
G. Dal Pozzo

The aqueductal CSF and superior sagittal sinus (SSS) blood flow were quantified in 9 healthy volunteers using a Phase Contrast Cine MR technique with retrospective cardiac gating and velocity of encoding of 10 and 30 cm/s. All subjects were examined in basal conditions, during hypocapnia determined by sustained hyperventilation and during hypercapnia (>5%) obtained with rebreathing in a plastic bag. In basal conditions, the aqueductal CSF flow area showed a mean increase of 24% synchronous with the cerebral systole, whereas variations of the SSS flow area during the cardiac cycle were negligible (>9%). The mean flow velocity and volume in the SSS were 11.7 cm/s and 236 ml/min. Mean peak systolic and diastolic aqueductal CSF velocity were + 2 cm/s and −2 cm/s. Hypocapnia determined in all but one subjects a decrease of the SSS blood and aqueductal CSF velocities. During hypocapnia a decrease of the aqueductal CSF flow area was also observed. Hypercapnia was associated with a decrease of the SSS flow velocity in 3 subjects and to minor changes in the remaining 6 subjects. Hypercapnia determined an increase (up to 30%) in the peak systolic and diastolic aqueductal CSF flow velocity in 3 subjects, negligible changes in 5 subjects and a decrease of the same parameters in one subject. The aqueductal CSF flow area was decreased in 8 subjects during hypercapnia. Hypocapnia and hypercapnia are relatively simple tests which can be used to modify the intracranial hydrodynamic equilibrium in healthy subjects. Further investigations are however needed before their application to the study of intracranial hydrodynamics in patients with hydrocephalus.


Sign in / Sign up

Export Citation Format

Share Document