scholarly journals The Performance of V-Trough Solar Concentrator Photovoltaic Systems at Varying Panel Surface Temperatures

The photovoltaic (PV) panel performances are dependent upon many factors. A study was executed to ascertain the effect of a V-Trough Concentrator (VTC) to be engaged on a PV Panel in this research where the performance of PV panels are compared at different surface temperatures both back and front. The experiment was conducted using two similar rated monocrystalline PV panels. One of the PV panels was installed with a VTC while the other is without the VTC that served as Control for benchmark purposes. The optimum VTC selected is a 60° VTC. Both PV systems were built with a lower supporting mechanism and were placed to operate under similar operating and weather situations, while the PV panel surface temperature both front surface and back surface, Open Circuit Voltage (Voc), as well as Short-Circuit Current (Isc) readings are being recorded down at specific time. The theoretical output is determined and compared. This paper ends with a presentation of the results obtained in a study on the PV panel surfaces temperature in relation to its performance by PV system using a 60o VTC.

2021 ◽  
Vol 54 (6) ◽  
pp. 847-852
Author(s):  
Asadi Suresh Kumar ◽  
Vyza Usha Reddy

One of the major concerns for continuous solar photovoltaic (PV) generation is partial shading. The movement of clouds, shadow of buildings, trees, birds, litter and dust, etc., can lead to partial shadow conditions (PSCs). The PSCs have caused inconsistent power losses in the PV modules. This leads to a shortage of electricity production and the presence in the PV curve of several peaks. One of the simplest solutions to PSC’s is the PV configurations. The objective of this paper is modelling and simulation of solar PV system in various shading scenarios for KC200GT 200 W, 5 x 5 configurations that includes Series/Parallel (SP), Total-Cross-Tied (TCT), Triple-Tied (TT), Bridge-Link (BL) configurations. Real time PSC’s such as corner, center, frame, random, diagonal, right side end shading conditions are evaluated under all PV array configurations. A comparative analysis is carried out for the parameters such as open circuit voltage, short circuit current, maximum power point, panel mismatch losses, fill factor, efficiency under all PV configurations considering PSC’s. From the comparison analysis best configuration will be presented.


2018 ◽  
Vol 144 ◽  
pp. 04004 ◽  
Author(s):  
Tripathi Abhishek Kumar ◽  
Ch. S. N Murthy ◽  
Aruna Mangalpady

The surface temperature of PV panel has an adverse impact on its performance. The several electrical parameters of PV panel, such as open circuit voltage, short circuit current, power output and fill factor depends on the surface temperature of PV panel. In the present study, an experimental work was carried out to investigate the influence of PV panel surface temperature on its electrical parameters. The results obtained from this experimental study show a significant reduction in the performance of PV panel with an increase in panel surface temperature. A 5W PV panel experienced a 0.4% decrease in open circuit voltage for every 1°C increase in panel surface temperature. Similarly, there was 0.6% and 0.32% decrease in maximum power output and in fill factor, respectively, for every 1°C increase in panel surface temperature. On the other hand, the short circuit current increases with the increase in surface temperature at the rate of 0.09%/°C.


2017 ◽  
Vol 6 (3) ◽  
pp. 225
Author(s):  
Abhishek Kumar Tripathi ◽  
M. Aruna ◽  
Ch.S.N. Murthy

The performance of PV panel depends on the incoming sunlight on its surface. The accumulated airborne dust particles on panel surface creates a barrier in the path of sunlight and panel surface, which significantly reduces the amount of solar radiation falling on the panel surface. The present study shows a significant reduction in short circuit current and power output of PV panel due to dust deposition on its surface, whereas the reduction in open circuit voltage is not much prominent. This study has been carried in the field as well as in the laboratory. The reduction in maximum power output of PV panel for both the studies ensures a linear relation with the dust deposition on its surface. In the field study, the reduction in the power output due to 12.86gm of dust deposition on the panel surface was 43.18%, whereas in the laboratory study it was 44.75% due to 11gm of dust depositionArticle History: Received July 10th 2017; Received in revised form Sept 15th 2017x; Accepted 1st Oct 2017; Available onlineHow to Cite This Article: Tripathi, A.K., Aruna, M. and Murthy, Ch.,S.N. (2017). Performance Evaluation of PV Panel Under Dusty Condition. International Journal of Renewable Energy Develeopment, 6(3), 225-233.https://doi.org/10.14710/ijred.6.3.225-233 


Author(s):  
Adnan Hussein Ali ◽  
Hassan Salman Hamad ◽  
Ali Abdulwahhab Abdulrazzaq

<p>Photovoltaic (PV) systems are normally modeled by employing accurate equations dealing with a behavior the PV system. This model has Characteristic of PV array cells, which are influenced by both irradiation and temperature variations. Grid-connected PV system is considered as electricity generated solar cell system which is connected to the grid utilities. This paper characterizes an exhibiting and simulating of PV system that executed with MATLAB /Simulink. The impact of solar irradiances as well as ambient temperature performances of PV models is investigated and noted that a lower temperature provides maximum power higher so that the open circuit voltage is larger. Furthermore, if the temperature is low, then a considerably short circuit current is low too.</p>


2020 ◽  
Vol 92 (2) ◽  
pp. 20901
Author(s):  
Abdul Kuddus ◽  
Md. Ferdous Rahman ◽  
Jaker Hossain ◽  
Abu Bakar Md. Ismail

This article presents the role of Bi-layer anti-reflection coating (ARC) of TiO2/ZnO and back surface field (BSF) of V2O5 for improving the photovoltaic performance of Cadmium Sulfide (CdS) and Cadmium Telluride (CdTe) based heterojunction solar cells (HJSCs). The simulation was performed at different concentrations, thickness, defect densities of each active materials and working temperatures to optimize the most excellent structure and working conditions for achieving the highest cell performance using obtained optical and electrical parameters value from the experimental investigation on spin-coated CdS, CdTe, ZnO, TiO2 and V2O5 thin films deposited on the glass substrate. The simulation results reveal that the designed CdS/CdTe based heterojunction cell offers the highest efficiency, η of ∼25% with an enhanced open-circuit voltage, Voc of 0.811 V, short circuit current density, Jsc of 38.51 mA cm−2, fill factor, FF of 80% with bi-layer ARC and BSF. Moreover, it appears that the TiO2/ZnO bi-layer ARC, as well as ETL and V2O5 as BSF, could be highly promising materials of choice for CdS/CdTe based heterojunction solar cell.


Author(s):  
Mohammed Bouzidi ◽  
Abdelkader Harrouz ◽  
Tadj Mohammed ◽  
Smail Mansouri

<p>The inverter is the principal part of the photovoltaic (PV) systems that assures the direct current/alternating current (DC/AC) conversion (PV array is connected directly to an inverter that converts the DC energy produced by the PV array into AC energy that is directly connected to the electric utility). In this paper, we present a simple method for detecting faults that occurred during the operation of the inverter. These types of faults or faults affect the efficiency and cost-effectiveness of the photovoltaic system, especially the inverter, which is the main component responsible for the conversion. Hence, we have shown first the faults obtained in the case of the short circuit. Second, the open circuit failure is studied. The results demonstrate the efficacy of the proposed method. Good monitoring and detection of faults in the inverter can increase the system's reliability and decrease the undesirable faults that appeared in the PV system. The system behavior is tested under variable parameters and conditions using MATLAB/Simulink.</p>


2012 ◽  
Vol 472-475 ◽  
pp. 1846-1850
Author(s):  
Shan Shan Dai ◽  
Gao Jie Zhang ◽  
Xiang Dong Luo ◽  
Jing Xiao Wang ◽  
Wen Jun Chen ◽  
...  

In this work, the effect of aluminum back surface field formed by screen printed various amount of Al paste on the effective rear surface recombination velocity (Seff) and the internal rear reflectance coeffeicient (Rb) of commercial mono-silicon solar cells was investigated. We demonstrated the effect of Seffand Rbon the performance of Al-BSF solar cells by simulating them with PC1D. The simulated results showed that the lower Seffcould get higher open circuit voltage (Voc), at the same time, the larger Rbcould get higher short-circuit current (Isc). Experimentally, we investigated the Seffand Rbthrough depositing Al paste with various amount (3.7, 5, 6, and 8 mg/cm2) for fabricating Al-BSF mono-silicon solar cells. Four group cells were characterized by light I-V, spectral response, hemispherical reflectance and scanning electron microscope (SEM) measurements. It was found that, a minimum Seffof 350 cm/s was gotten from the cells with Al paste of 8 mg/cm2, which was extracted by matching quantum efficiency (QE) from 800 nm to 1200 nm with PC1D, and a maximum Rbof 53.5% was obtained from Al paste of 5 mg/cm2by calculating at 1105 nm with PC1D. When the amount of Al paste was higher than 5mg/cm2, there were less Seffand lower Rb. On the other hand, when Al amount was 3.7mg/cm2, it was too little to form a closed BSF. Based on the SEM graphs and simulations with PC1D, a simple explaination was proposed for the experimental results.


Electronics ◽  
2019 ◽  
Vol 8 (3) ◽  
pp. 321 ◽  
Author(s):  
Dmitry Baimel ◽  
Saad Tapuchi ◽  
Yoash Levron ◽  
Juri Belikov

This paper proposes two new Maximum Power Point Tracking (MPPT) methods which improve the conventional Fractional Open Circuit Voltage (FOCV) method. The main novelty is a switched semi-pilot cell that is used for measuring the open-circuit voltage. In the first method this voltage is measured on the semi-pilot cell located at the edge of PV panel. During the measurement the semi-pilot cell is disconnected from the panel by a pair of transistors, and bypassed by a diode. In the second Semi-Pilot Panel method the open circuit voltage is measured on a pilot panel in a large PV system. The proposed methods are validated using simulations and experiments. It is shown that both methods can accurately estimate the maximum power point voltage, and hence improve the system efficiency.


2013 ◽  
Vol 16 (1) ◽  
pp. 48-56
Author(s):  
Vu Ngoc Hoang ◽  
Linh Ngoc Tran ◽  
Lan Truong ◽  
Khoa Thanh Nhat Phan ◽  
Chien Mau Dang ◽  
...  

In this report we present series of experiments during which the short circuit current of mono crystalline silicon solar cell was improved step by step so as a consequence the efficiency was increased. At first, the front contact of solar cell was optimized to reduce the shadow loss and the series resistance. Then surface treatments were prepared by TMAH solution to reduce the total light reflectance and to improve the light trapping effect. Finally, antireflection coatings were deposited to passivate the front surface either by silicon nitride thin layer or to increase the collection probability by indium tin oxide layer, and to reduce the reflectance of light. As a result, solar cells of about 13% have been obtained, with the average open circuit voltage Voc about 527mV, with the fill factor about 68% and the short circuit current about 7.92 mA/cm2 under the irradiation density of 21 mW/cm2.


2021 ◽  
Vol 19 ◽  
pp. 598-603 ◽  
Author(s):  
C.B. Nzoundja Fapi ◽  
◽  
P. Wira ◽  
M. Kamta ◽  

To substantially increase the efficiency of photovoltaic (PV) systems, it is important that the Maximum Power Point Tracking (MPPT) system has an output close to 100%.This process is handled by MPPT algorithms such as Fractional Open-Circuit Voltage (FOCV), Perturb and Observe (P&O), Fractional Short-Circuit Current (FSCC), Incremental Conductance (INC), Fuzzy Logic Controller (FLC) and Neural Network (NN) controllers. The FSCC algorithm is simple to be implemented and uses only one current sensor. This method is based on the unique existence of the linear approximation between the Maximum Power Point (MPP) current and the short-circuit current in standard conditions. The speed of this MPPT optimization technic is fast, however this algorithm needs to short-circuit the PV panel each time in order to obtain the short circuit current. This process leads to energy losses and high oscillations. In order to improve the FSCC algorithm, we propose a method based on the direct detection of the shortcircuit current by simply reading the output current of the PV panel. This value allows directly calculating the short circuit current by incrementing or decrementing the solar irradiation. Experimental results show time response attenuation, little oscillations, power losses reduction and better MPPT accuracy of the enhanced algorithm compared to the conventional FSCC method.


Sign in / Sign up

Export Citation Format

Share Document