scholarly journals Analysis of Primary Energy Consumption in the United States

2021 ◽  
Vol 16 ◽  
pp. 178-184
Author(s):  
A. A. Vysotskaya ◽  
A. A. Vorontsov ◽  
R. I. Dzerzhinsky

This article examines the overall trend in primary energy consumption from 1635 to 2020 in the United States. Based on the exponential growth model, the annual energy consumption average growth rate and the process characteristic time are determined. The anamorphosis method is used to search for the logistic model parameters. Long-term trends analysis and the corresponding time series fluctuations are carried out. For the fluctuations' analysis, the trend component is preliminarily excluded based on the proportions theory. Near-period values are determined using shift and autocorrelation functions. To predict further energy consumption dynamics, the ARIMA autoregressive model is used, on which basis a local increase in the annual energy consumption level to 97.66 quads Btu is expected by 2025. The US energy consumption dynamics by resource type is considered. A forecast up to 2025 for the primary energy resources consumption shares in their total volume is built on an autoregressive model basis

2012 ◽  
Vol 9 (2) ◽  
pp. 65
Author(s):  
Alhassan Salami Tijani ◽  
Nazri Mohammed ◽  
Werner Witt

Industrial heat pumps are heat-recovery systems that allow the temperature ofwaste-heat stream to be increased to a higher, more efficient temperature. Consequently, heat pumps can improve energy efficiency in industrial processes as well as energy savings when conventional passive-heat recovery is not possible. In this paper, possible ways of saving energy in the chemical industry are considered, the objective is to reduce the primary energy (such as coal) consumption of power plant. Particularly the thermodynamic analyses ofintegrating backpressure turbine ofa power plant with distillation units have been considered. Some practical examples such as conventional distillation unit and heat pump are used as a means of reducing primary energy consumption with tangible indications of energy savings. The heat pump distillation is operated via electrical power from the power plant. The exergy efficiency ofthe primary fuel is calculated for different operating range ofthe heat pump distillation. This is then compared with a conventional distillation unit that depends on saturated steam from a power plant as the source of energy. The results obtained show that heat pump distillation is an economic way to save energy if the temperaturedifference between the overhead and the bottom is small. Based on the result, the energy saved by the application of a heat pump distillation is improved compared to conventional distillation unit.


Author(s):  
Hongtao Liu ◽  
Karen R. Polenske ◽  
Joaquim Guilhoto ◽  
Youmin Xi

Energies ◽  
2021 ◽  
Vol 14 (9) ◽  
pp. 2538
Author(s):  
Praveen K. Cheekatamarla

Electrical and thermal loads of residential buildings present a unique opportunity for onsite power generation, and concomitant thermal energy generation, storage, and utilization, to decrease primary energy consumption and carbon dioxide intensity. This approach also improves resiliency and ability to address peak load burden effectively. Demand response programs and grid-interactive buildings are also essential to meet the energy needs of the 21st century while addressing climate impact. Given the significance of the scale of building energy consumption, this study investigates how cogeneration systems influence the primary energy consumption and carbon footprint in residential buildings. The impact of onsite power generation capacity, its electrical and thermal efficiency, and its cost, on total primary energy consumption, equivalent carbon dioxide emissions, operating expenditure, and, most importantly, thermal and electrical energy balance, is presented. The conditions at which a cogeneration approach loses its advantage as an energy efficient residential resource are identified as a function of electrical grid’s carbon footprint and primary energy efficiency. Compared to a heat pump heating system with a coefficient of performance (COP) of three, a 0.5 kW cogeneration system with 40% electrical efficiency is shown to lose its environmental benefit if the electrical grid’s carbon dioxide intensity falls below 0.4 kg CO2 per kWh electricity.


Energies ◽  
2019 ◽  
Vol 12 (19) ◽  
pp. 3775 ◽  
Author(s):  
Khaled Bawaneh ◽  
Farnaz Ghazi Nezami ◽  
Md. Rasheduzzaman ◽  
Brad Deken

Healthcare facilities in the United States account for 4.8% of the total area in the commercial sector and are responsible for 10.3% of total energy consumption in this sector. The number of healthcare facilities increased by 22% since 2003, leading to a 21% rise in energy consumption and an 8% reduction in energy intensity per unit of area (544.8 kWh/m2). This study provides an analytical overview of the end-use energy consumption data in healthcare systems for hospitals in the United States. The energy intensity of the U.S. hospitals ranges from 640.7 kWh/m2 in Zone 5 (very hot) to 781.1 kWh/m2 in Zone 1 (very cold), with an average of 738.5 kWh/m2. This is approximately 2.6 times higher than that of other commercial buildings. High energy intensity in the healthcare facilities, particularly in hospitals, along with energy costs and associated environmental concerns make energy analysis crucial for this type of facility. The proposed analysis shows that U.S. healthcare facilities have higher energy intensity than those of most other countries, especially the European ones. This necessitates the adoption of more energy-efficient approaches to the infrastructure and the management of healthcare facilities in the United States.


2018 ◽  
Vol 882 ◽  
pp. 215-220
Author(s):  
Matthias Koppmann ◽  
Raphael Lechner ◽  
Tom Goßner ◽  
Markus Brautsch

Process cooling and air conditioning are becoming increasingly important in the industry. Refrigeration is still mostly accomplished with compression chillers, although alternative technologies are available on the market that can be more efficient for specific applications. Within the scope of the project “EffiCool” a technology toolbox is currently being developed, which is intended to assist industrials users in selecting energy efficient and eco-friendly cooling solutions. In order to assess different refrigeration options a consistent methodology was developed. The refrigeration technologies are assessed regarding their efficiency, CO2-emissions and primary energy consumption. For CCHP systems an exergetic allocation method was implemented. Two scenarios with A) a compression chiller and B) an absorption chiller coupled to a natural gas CHP system were calculated exemplarily, showing a greater overall efficiency for the CCHP system, although the individual COP of the chiller is considerably lower.


Author(s):  
Viral K. Patel ◽  
Kyle R. Gluesenkamp

This paper provides an overview of a thermoelectric heat pump clothes dryer which was developed with the aim of reducing the significant primary energy consumption attributed to residential electric clothes drying in the United States (623 TBtu/yr). The use of thermoelectric modules in place of the conventional electric resistance heater resulted in a 40% reduction in the energy consumption of the system, compared to the minimum energy efficiency standard. This was achieved for the first time for a standard test load of 8.45 lb, using a clothes dryer prototype with a thermoelectric heat pump module as the sole heating mechanism. The current experimental prototype was developed after extensive modeling, system design and control optimization, and experimental system-level evaluation of control parameters. The demonstration of improved energy consumption has laid the foundation for future development of this technology.


Author(s):  
J Harrod ◽  
P J Mago

Due to the soaring costs and demand of energy in recent years, combined cooling, heating, and power (CCHP) systems have arisen as an alternative to conventional power generation based on their potential to provide reductions in cost, primary energy consumption, and emissions. However, the application of these systems is commonly limited to internal combustion engine prime movers that use natural gas as the primary fuel source. Investigation of more efficient prime movers and renewable fuel applications is an integral part of improving CCHP technology. Therefore, the objective of this study is to analyse the performance of a CCHP system driven by a biomass fired Stirling engine. The study is carried out by considering an hour-by-hour CCHP simulation for a small office building located in Atlanta, Georgia. The hourly thermal and electrical demands for the building were obtained using the EnergyPlus software. Results for burning waste wood chip biomass are compared to results obtained burning natural gas to illustrate the effects of fuel choice and prime mover power output on the overall CCHP system performance. Based on the specified utility rates and including excess production buyback, the results suggest that fuel prices of less than $23/MWh must be maintained for savings in cost compared to the conventional case. In addition, the performance of the CCHP system using the Stirling engine is compared with the conventional system performance. This comparison is based on operational cost and primary energy consumption. When electricity can be sold back to the grid, results indicate that a wood chip fired system yields a potential cost savings of up to 50 per cent and a 20 per cent increase in primary energy consumption as compared with the conventional system. On the other hand, a natural gas fired system is shown to be ineffective for cost and primary energy consumption savings with increases of up to 85 per cent and 24 per cent compared to the conventional case, respectively. The variations in the operational cost and primary energy consumption are also shown to be sensitive to the electricity excess production and buyback rate.


2005 ◽  
Vol 9 (3) ◽  
pp. 7-14 ◽  
Author(s):  
Hiromi Yamamoto ◽  
Kenji Yamaji

The uses of fossil fuels cause not only the resources exhaustion but also the environmental problems such as global warming. The purposes of this study are to evaluate paths to ward sustainable energy systems and roles of each renewable. In order to realize the purposes, the authors developed the global land use and energy model that figured the global energy supply systems in the future considering the cost minimization. Using the model the authors conducted a simulation in C30R scenario, which is a kind of strict CO2 emission limit scenarios and reduced CO2 emissions by 30% compared with Kyoto protocol forever scenario, and obtained the following results. In C30R scenario bio energy will supply 33% of all the primary energy consumption. How ever, wind and photo voltaic will supply 1.8% and 1.4% of all the primary energy consumption, respectively, because of the limits of power grid stability. The results imply that the strict limits of CO2 emissions are not sufficient to achieve the complete renewable energy systems. In order to use wind and photo voltaic as major energy resources we need not only to reduce the plant costs but also to develop unconventional renewable technologies. .


Sign in / Sign up

Export Citation Format

Share Document