scholarly journals The efficiency of municipal sewage treatment plants inspiration for water recovery

2021 ◽  
Vol 2021 ◽  
Author(s):  
Karolina Wójcicka

This article presents a detailed analysis of the functioning of municipal sewage treatment plants. The presented findings are based on questionnaires from over seventy wastewater treatment facilities, covering from several hundred to several hundred thousand inhabitants. The required quality of treated sewage and the necessary efficiency level of the treatment plant were determined in the context of the content of the applicable regulations, and were then compared with the actual data obtained from sewage treatment plants. The findings provided the basis for formulating an evaluation of the efficiency of municipal sewage treatment plants and for further analyses of the possibility of the recovery of water from sewage and its reuse.

2008 ◽  
Vol 37 (2) ◽  
Author(s):  
Maciej Walczak

Changes of microbial indices of water quality in the Vistula and Brda rivers as a result of sewage treatment plant operationThis paper reports the results of studies of microbiological changes in the water quality of the Vistula and Brda rivers after the opening of sewage treatment plants in Bydgoszcz. The study involved determining the microbiological parameters of water quality. Based on the results obtained, it was found that the quality of the water in both rivers had improved decidedly after the opening of the plants, although an increased number of individual groups of microorganisms was found at the treated sewage outlet from one of the plants.


Proceedings ◽  
2019 ◽  
Vol 16 (1) ◽  
pp. 18
Author(s):  
Magdalena Łój-Pilch ◽  
Anita Zakrzewska ◽  
Ewa Zielewicz

Risk management, an aspect of which is risk assessment, is a process supporting the proper function of municipal sewage treatment plants. Many factors affect the quality of treated wastewater. Risk assessment, its analysis, and hierarchization permit the elimination of events with the most destructive impacts on the purification process.


2019 ◽  
Vol 29 (3) ◽  
pp. 209-217
Author(s):  
Dariusz Królik ◽  
Przemysław Wypych ◽  
Jakub Kostecki

Abstract Sewage sludge produced in municipal sewage treatment plants, because of its physicochemical and sanitary properties, is a serious threat to the environment. In order to neutralize it, various methods of processing are used, which directly affect the quantity and quality of produced sewage sludge, which in the final stage can be used naturally. Properly managed sludge management is presented on the example of a sewage treatment plant, conducting the methane fermentation process with the production of biogas.


2013 ◽  
Vol 671-674 ◽  
pp. 2736-2741
Author(s):  
Yin An Ming ◽  
Tao Tao

To reuse municipal sewage sludge safely, experiment was carried out on grapefruit trees fertilized with composted sludge from Shiweitou Sewage Treatment Plant in Xiamen City of China, and a method was introduced of how to assess the environmental quality of grapefruit trees soil fertilized with sludge by Set Pair Analysis (SPA) model. The results showed that the soil in the surface layer (0-15cm) and the deeper layer (15-30cm) was less clean, and the environment of soil was not polluted. Thus it was feasible to use sludge as fruit fertilizer. The maximum service life of sludge for continuous land application was estimated by taking Cd as the limiting factor, which would provide scientific guide and technical support for safe land application of sludge.


2019 ◽  
Vol 85 ◽  
pp. 02011
Author(s):  
Alexandru Fodorean ◽  
Adrian Cureu ◽  
Oana Giurgiu ◽  
Dan Opruţa

Sewage treatment remains a delicate subject and requires technical improvements to increase the efficiency of the systems responsible for the treatment. Numerical simulations are also a very useful tool, especially if they are used during the design phase. Thus, the paper aims to present the results obtained by CFD numerical simulations in the case of an important element within an existing wastewater treatment plant, namely the waste water treatment well, thus obtaining constructive solutions of a better functionally to the designed version. Through these, the work demonstrates the necessity of analyzes with CFD methods during design of the main elements of hydrotechnical constructions, but also the necessity of adjusting the numerical models with results obtained from experiments, measurements. The results show that the modifications described in the paper would bring significant improvements in waste disposal.


Author(s):  
R. Babko ◽  
V. Pliashechnyk ◽  
T. Kuzmina ◽  
Y. Danko ◽  
J. Szulżyk-Cieplak ◽  
...  

Abstract The work is devoted to the task of simplifying the assessment of the effect of effluents from treatment facilities on the river hydrobiocenosis. The studies were carried out on the mountain river Uzh (Uzhgorod, Ukraine). Our approach to assessing the impact of waste treatment facilities on the river receiver is based on the estimate of the similarity of species composition and quantitative characteristics of populations of organisms from the aerotank and from the river. It is shown that the quantitative development of populations of species of ciliates from the aeration tank is a good indicator for assessing the degradation of organic matter coming with wastewater. The use of qualitative and quantitative characteristics of the protozoa from the wastewater treatment plant as a criterion for assessing the quality of the environment in the area of wastewater discharge showed their representativeness and effectiveness. The use of a limited number of species makes it possible to conduct an express assessment of the effect of effluents on receiving reservoirs for specialists working with activated sludge in the laboratories of treatment facilities.


2018 ◽  
Vol 45 ◽  
pp. 00036
Author(s):  
Zbigniew Kowalewski

The process of designing and exploiting municipal sewage treatment plants has become much simpler and more efficient thanks to mathematical modeling. The ASM model family is able to simulate the operation of existing or designed objects in a satisfactory manner. The basic problem in Poland is the insufficient amount of data for simulations coming from plant monitoring. It is provided to create unstable model results with difficulties in calibration and validation. The aim of this article is to confirm how the amount of data and its completeness will affect the quality of the simulation performed in the ASM model. The study object is a sewage treatment plant located in Chicago in the USA. It is a sewage treatment plant operating with activated sludge technology, with regular monitoring of the quality of raw and treated wastewater. For modeling, a variant of the ASM model built into the BioWin 5.2 software was used.


2019 ◽  
Vol 252 ◽  
pp. 09009
Author(s):  
Dariusz Majerek ◽  
Sylwia Duda ◽  
Roman Babko ◽  
Marcin K. Widomski

The assessment of the ratio of self-purification processes in the natural environment, including the water bodies of streams and rivers is possible by the means of the numerical modelling. Nonetheless, the reliability of results of the qualitative numerical calculations may be affected by the quality of the collected input data and efficiency of the model calibration. The commonly required input data include pollutants characteristics and coefficients for empirical equations of their transport and decay, while calibration of a model requires series of measurements of selected pollutants concentration in water. This paper presents studies of concentration of pollutants measured in the treated sanitary wastewater discharged to the Bystrzyca river from municipal wastewater treatment plant, and their concentrations measured directly in the river, above and below the location of discharge point. The performed qualitative measurements of treated sewage discharged from municipal wastewater treatment plant and water of the Bystrzyca river included determination of COD, BOD5, N-NH4, N-NO2, N-NNO3, TKN, TN, TP and TSS concentration. The presented results of measurements are the first step in development and calibration of the model, allowing to successfully predict the influence of discharged sanitary wastewater on quality of water in the river.


1994 ◽  
Vol 30 (4) ◽  
pp. 25-34
Author(s):  
M. Ettala ◽  
E. Rossi

Seven operational mishaps were specified on the basis of a questionnaire on wastewater treatment plants, some of them large. In this study a process was developed for screening the chemical spill risks to municipal biological sewage treatment plant. Data on wastewater treatment processes, potential spill sources and chemical properties were combined to determine the threshold chemical quantities which may inhibit the removal of carbonaceous material, prevent nitrification and methanogenesis, cause sludge contamination or lead to the aeration capacity being exceeded. Two sewage treatment plants and eleven industrial sites were chosen for field studies. The influence of spill duration and maintenance activities on threshold quantities are discussed. A field survey lasting 1-2 hours at each site was long enough for the most relevant data to be obtained when the screening method developed was applied. Several chemical spill risks to the plants studied were specified. In addition, cases were identified in which failure of the pretreatment facilities for industrial wastewaters could cause severe mishaps at a biological wastewater treatment plant.


2017 ◽  
Vol 21 (3) ◽  
pp. 16-20 ◽  
Author(s):  
V.V. Kul’nev ◽  
V.I. Stupin ◽  
A.A. Borzenkov

The article deals with theoretical and practical aspects of biological waste water rehabilitation of sugar factories by algocoenosis correction. This technology allows you to transfer domestic sewage treatment plant of filtration mode fields in the biological treatment ponds mode, significantly reducing the area of sewage treatment plants, thus improving the quality of treated waste water, which will, in turn, use them repeatedly reducing total water consumption.


Sign in / Sign up

Export Citation Format

Share Document