Experimental Investigation of Integrated Heat Pipe Heat Sink for Multi-chip LED Module in Natural Convection

2014 ◽  
Vol 35 (11) ◽  
pp. 1394-1400
Author(s):  
周驰 ZHOU Chi ◽  
左敦稳 ZUO Dun-wen ◽  
孙玉利 SUN Yu-li
Author(s):  
H. B. Ma ◽  
K. P. Lofgreen ◽  
G. P. Peterson

An experimental investigation on a highly efficient heat pipe heat sink was investigated, in which the interline region was optimized using sintered particles. The effects of condenser size, sintered particles, and forced air flow on the heat transfer performance were investigated experimentally. The experimental results indicated that the thin film evaporation could significantly increase the evaporating heat transfer coefficient and remove heat fluxes up to 800 kW/m2. In addition, a theoretical model capable of predicting the temperature drop occurring in the device was developed. The predicted performance was in good agreement with the experimental data. The resulting model can be used to assist in the design of high heat flux, heat pipe heat sinks for applications to both ground based and spacecraft applications.


2005 ◽  
Vol 128 (1) ◽  
pp. 18-22 ◽  
Author(s):  
H. B. Ma ◽  
K. P. Lofgreen ◽  
G. P. Peterson

An experimental investigation of a highly efficient heat pipe heat sink was investigated, in which the interline region was optimized using sintered particles. The effects of condenser size, sintered particles, and forced air flow on the heat transfer performance were investigated experimentally. The experimental results indicated that the thin film evaporation could significantly increase the evaporating heat transfer coefficient and remove heat fluxes up to 800kW∕m2. In addition, a theoretical model capable of predicting the temperature drop occurring in this device was developed. The predicted performance was in good agreement with the experimental data and the resulting model can be used to assist in the design of high heat flux, heat pipe heat sinks.


2019 ◽  
Author(s):  
Sakil Hossen ◽  
AKM M. Morshed ◽  
Amitav Tikadar ◽  
Azzam S. Salman ◽  
Titan C. Paul

Energies ◽  
2020 ◽  
Vol 13 (20) ◽  
pp. 5282
Author(s):  
Eui-Hyeok Song ◽  
Kye-Bock Lee ◽  
Seok-Ho Rhi ◽  
Kibum Kim

A concentric annular heat pipe heat sink (AHPHS) was proposed and fabricated to investigate its thermal behavior. The present AHPHS consists of two concentric pipes of different diameters, which create vacuumed annular vapor space. The main advantage of the AHPHS as a heat sink is that it can largely increase the heat transfer area for cooling compared to conventional heat pipes. In the current AHPHS, condensation takes place along the whole annular space from the certain heating area as the evaporator section. Therefore, the whole inner space of the AHPHS except the heating area can be considered the condenser. In the present study, AHPHSs of different diameters were fabricated and studied experimentally. Basic studies were carried out with a 50 mm-long stainless steel AHPHS with diameter ratios of 1.1 and 1.3 and the same inner tube diameter of 76 mm. Several experimental parameters such as volume fractions of 10–70%, different air flow velocity, flow configurations, and 10–50 W heat inputs were investigated to find their effects on the thermal performance of an AHPHS. Experimental results show that a 10% filling ratio was found to be the optimum charged amount in terms of temperature profile with a low heater surface temperature and water as the working fluid. For the methanol, a 40% filling ratio shows better temperature behavior. Internal working behavior shows not only circular motion but also 3-D flow characteristics moving in axial and circular directions simultaneously.


Sign in / Sign up

Export Citation Format

Share Document