Optical System of the Probe for a Micro-Raman Spectrometer

2012 ◽  
Vol 49 (3) ◽  
pp. 032204
Author(s):  
安岩 An Yan ◽  
孙强 Sun Qiang ◽  
朴仁官 Piao Renguan ◽  
刘英 Liu Ying ◽  
李淳 Li Chun
2017 ◽  
Vol 56 (13) ◽  
pp. 3639 ◽  
Author(s):  
Ming Tang ◽  
Fan Xianguang ◽  
Xin Wang ◽  
Jian He ◽  
Hao He ◽  
...  

2016 ◽  
Vol 36 (4) ◽  
pp. 0422001
Author(s):  
范贤光 Fan Xianguang ◽  
汤明 Tang Ming ◽  
王昕 Wang Xin ◽  
许英杰 Xu Yingjie ◽  
李韦 Li Wei ◽  
...  

2016 ◽  
Vol 55 (26) ◽  
pp. 7195 ◽  
Author(s):  
Ming Tang ◽  
Xin Wang ◽  
Fan Xianguang ◽  
Wei Li ◽  
Yingjie Xu ◽  
...  

Optics ◽  
2022 ◽  
Vol 3 (1) ◽  
pp. 1-7
Author(s):  
Muddasir Naeem ◽  
Noor-ul-ain Fatima ◽  
Mukhtar Hussain ◽  
Tayyab Imran ◽  
Arshad Saleem Bhatti

We report the design simulation of the Raman spectrometer using Zemax optical system design software. The design is based on the Czerny–Turner configuration, which includes an optical system consisting of an entrance slit, two concave mirrors, reflecting type diffraction grating and an image detector. The system’s modeling approach is suggested by introducing the corresponding relationship between detector pixels and wavelength, linear CCD receiving surface length and image surface dimension. The simulations were carried out using the POP (physical optics propagation) algorithm. Spot diagram, relative illumination, irradiance plot, modulation transfer function (MTF), geometric and encircled energy were simulated for designing the Raman spectrometer. The simulation results of the Raman spectrometer using a 527 nm wavelength laser as an excitation light source are presented. The present optical system was designed in sequential mode and a Raman spectrum was observed from 530 nm to 630 nm. The analysis shows that the system’s image efficiency was quite good, predicting that it could build an efficient and cost-effective Raman spectrometer for optical diagnostics.


2013 ◽  
Vol 33 (3) ◽  
pp. 0330001
Author(s):  
安岩 An Yan ◽  
刘英 Liu Ying ◽  
孙强 Sun Qiang ◽  
李淳 Li Chun ◽  
刘兵 Liu Bing ◽  
...  

Author(s):  
Michel Troyonal ◽  
Huei Pei Kuoal ◽  
Benjamin M. Siegelal

A field emission system for our experimental ultra high vacuum electron microscope has been designed, constructed and tested. The electron optical system is based on the prototype whose performance has already been reported. A cross-sectional schematic illustrating the field emission source, preaccelerator lens and accelerator is given in Fig. 1. This field emission system is designed to be used with an electron microscope operated at 100-150kV in the conventional transmission mode. The electron optical system used to control the imaging of the field emission beam on the specimen consists of a weak condenser lens and the pre-field of a strong objective lens. The pre-accelerator lens is an einzel lens and is operated together with the accelerator in the constant angular magnification mode (CAM).


Author(s):  
B. Roy Frieden

Despite the skill and determination of electro-optical system designers, the images acquired using their best designs often suffer from blur and noise. The aim of an “image enhancer” such as myself is to improve these poor images, usually by digital means, such that they better resemble the true, “optical object,” input to the system. This problem is notoriously “ill-posed,” i.e. any direct approach at inversion of the image data suffers strongly from the presence of even a small amount of noise in the data. In fact, the fluctuations engendered in neighboring output values tend to be strongly negative-correlated, so that the output spatially oscillates up and down, with large amplitude, about the true object. What can be done about this situation? As we shall see, various concepts taken from statistical communication theory have proven to be of real use in attacking this problem. We offer below a brief summary of these concepts.


Author(s):  
J T Fourie

The attempts at improvement of electron optical systems to date, have largely been directed towards the design aspect of magnetic lenses and towards the establishment of ideal lens combinations. In the present work the emphasis has been placed on the utilization of a unique three-dimensional crystal objective aperture within a standard electron optical system with the aim to reduce the spherical aberration without introducing diffraction effects. A brief summary of this work together with a description of results obtained recently, will be given.The concept of utilizing a crystal as aperture in an electron optical system was introduced by Fourie who employed a {111} crystal foil as a collector aperture, by mounting the sample directly on top of the foil and in intimate contact with the foil. In the present work the sample was mounted on the bottom of the foil so that the crystal would function as an objective or probe forming aperture. The transmission function of such a crystal aperture depends on the thickness, t, and the orientation of the foil. The expression for calculating the transmission function was derived by Hashimoto, Howie and Whelan on the basis of the electron equivalent of the Borrmann anomalous absorption effect in crystals. In Fig. 1 the functions for a g220 diffraction vector and t = 0.53 and 1.0 μm are shown. Here n= Θ‒ΘB, where Θ is the angle between the incident ray and the (hkl) planes, and ΘB is the Bragg angle.


Author(s):  
Fumio Watari ◽  
J. M. Cowley

STEM coupled with the optical system was used for the investigation of the early oxidation on the surface of Cr. Cr thin films (30 – 1000Å) were prepared by evaporation onto the polished or air-cleaved NaCl substrates at room temperature and 45°C in a vacuum of 10−6 Torr with an evaporation speed 0.3Å/sec. Rather thick specimens (200 – 1000Å) with various preferred orientations were used for the investigation of the oxidation at moderately high temperature (600 − 1100°C). Selected area diffraction patterns in these specimens are usually very much complicated by the existence of the different kinds of oxides and their multiple twinning. The determination of the epitaxial orientation relationship of the oxides formed on the Cr surface was made possible by intensive use of the optical system and microdiffraction techniques. Prior to the formation of the known rhombohedral Cr2O3, a thin spinel oxide, probably analogous to γ -Al203 or γ -Fe203, was formed. Fig. 1a shows the distinct epitaxial growth of the spinel (001) as well as the rhombohedral (125) on the well-oriented Cr(001) surface. In the case of the Cr specimen with the (001) preferred orientation (Fig. 1b), the rings explainable by spinel structure appeared as well as the well defined epitaxial spots of the spinel (001). The microdif fraction from 20A areas (Fig. 2a) clearly shows the same pattern as Fig. Ia with the weaker oxide spots among the more intense Cr spots, indicating that the thickness of the oxide is much less than that of Cr. The rhombohedral Cr2O3 was nucleated preferably at the Cr(011) sites provided by the polycrystalline nature of the present specimens with the relation Cr2O3 (001)//Cr(011), and by further oxidation it grew into full coverage of the rest of the Cr surface with the orientation determined by the initial nucleation.


Sign in / Sign up