Accurate Infrared Tracking System for Immersive Virtual Environments

Author(s):  
Filipe Gaspar ◽  
Rafael Bastos ◽  
Miguel Sales

In large-scale immersive virtual reality (VR) environments, such as a CAVE, one of the most common problems is tracking the position of the user’s head while he or she is immersed in this environment to reflect perspective changes in the synthetic stereoscopic images. In this paper, the authors describe the theoretical foundations and engineering approach adopted in the development of an infrared-optical tracking system designed for large scale immersive Virtual Environments (VE) or Augmented Reality (AR) settings. The system is capable of tracking independent retro-reflective markers arranged in a 3D structure in real time, recovering all possible 6DOF. These artefacts can be adjusted to the user’s stereo glasses to track his or her head while immersed or used as a 3D input device for rich human-computer interaction (HCI). The hardware configuration consists of 4 shutter-synchronized cameras attached with band-pass infrared filters and illuminated by infrared array-emitters. Pilot lab results have shown a latency of 40 ms when simultaneously tracking the pose of two artefacts with 4 infrared markers, achieving a frame-rate of 24.80 fps and showing a mean accuracy of 0.93mm/0.51º and a mean precision of 0.19mm/0.04º, respectively, in overall translation/rotation, fulfilling the requirements initially defined.

Author(s):  
Filipe Gaspar ◽  
Rafael Bastos ◽  
Miguel Sales

In large-scale immersive virtual reality (VR) environments, such as a CAVE, one of the most common problems is tracking the position of the user’s head while he or she is immersed in this environment to reflect perspective changes in the synthetic stereoscopic images. In this paper, the authors describe the theoretical foundations and engineering approach adopted in the development of an infrared-optical tracking system designed for large scale immersive Virtual Environments (VE) or Augmented Reality (AR) settings. The system is capable of tracking independent retro-reflective markers arranged in a 3D structure in real time, recovering all possible 6DOF. These artefacts can be adjusted to the user’s stereo glasses to track his or her head while immersed or used as a 3D input device for rich human-computer interaction (HCI). The hardware configuration consists of 4 shutter-synchronized cameras attached with band-pass infrared filters and illuminated by infrared array-emitters. Pilot lab results have shown a latency of 40 ms when simultaneously tracking the pose of two artefacts with 4 infrared markers, achieving a frame-rate of 24.80 fps and showing a mean accuracy of 0.93mm/0.51º and a mean precision of 0.19mm/0.04º, respectively, in overall translation/rotation, fulfilling the requirements initially defined.


2014 ◽  
Vol 1049-1050 ◽  
pp. 1233-1236
Author(s):  
Hui Qin Sun

This paper is to build a interior Large-scale multi-target precise positioning and tracking system.In-depth resear of a visual-based optical tracking technology, inertial tracking technology and multi-sensor data fusion technology.Breaking the graphics, images, data fusion, tracking and other related key technologies.Develop high versatility, real-time, robustness of a wide range of high-precision optical tracking system for interior Large-scale multi-target precise positioning and tracking system.


2012 ◽  
Vol 249-250 ◽  
pp. 1277-1282
Author(s):  
Bo Yang ◽  
Ya Zhou ◽  
Xiao Ming Hu ◽  
Jun Qin Lin ◽  
Qiao Na Xing

Endoscopic surgery is increasing for minimally invasive treatment in recent years.But the conventional two-dimensional endoscope technique cannot provide three-dimensional information for surgeon. Lacking depth and other 3D information often made doctorshave to carry out the surgery depending heavily clinical experience.In response to the above described issues,this paper proposed a method based on improved SIFT algorithmto recover 3D structure information of the endoscopic environment, with the help of an optical tracking system which can provide the orientation of the camera in real time. The proposed approach is evaluated on sequence digital images gotten from an 1394 camera and the experimental results show that the proposed approach iseffective.


2021 ◽  
Vol 11 (9) ◽  
pp. 3947
Author(s):  
Marco Farronato ◽  
Gianluca M. Tartaglia ◽  
Cinzia Maspero ◽  
Luigi M. Gallo ◽  
Vera Colombo

Clinical use of portable optical tracking system in dentistry could improve the analysis of mandibular movements for diagnostic and therapeutic purposes. A new workflow for the acquisition of mandibular kinematics was developed. Reproducibility of measurements was tested in vitro and intra- and inter-rater repeatability were assessed in vivo in healthy volunteers. Prescribed repeated movements (n = 10) in three perpendicular directions of the tracking-device coordinate system were performed. Measurement error and coefficient of variation (CV) among repetitions were determined. Mandibular kinematics of maximum opening, left and right laterality, protrusion and retrusion of five healthy subjects were recorded in separate sessions by three different operators. Obtained records were blindly examined by three observers. Intraclass correlation coefficient (ICC) was calculated to estimate inter-rater and intra-rater reliability. Maximum in vitro measurement error was 0.54 mm and CV = 0.02. Overall, excellent intra-rater reliability (ICC > 0.90) for each variable, general excellent intra-rater reliability (ICC = 1.00) for all variables, and good reliability (ICC > 0.75) for inter-rater tests were obtained. A lower score was obtained for retrusion with “moderate reliability” (ICC = 0.557) in the inter-rater tests. Excellent repeatability and reliability in optical tracking of primary movements were observed using the tested portable tracking device and the developed workflow.


Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2528
Author(s):  
Songlin Bi ◽  
Yonggang Gu ◽  
Jiaqi Zou ◽  
Lianpo Wang ◽  
Chao Zhai ◽  
...  

A high precision optical tracking system (OTS) based on near infrared (NIR) trinocular stereo vision (TSV) is presented in this paper. Compared with the traditional OTS on the basis of binocular stereo vision (BSV), hardware and software are improved. In the hardware aspect, a NIR TSV platform is built, and a new active tool is designed. Imaging markers of the tool are uniform and complete with large measurement angle (>60°). In the software aspect, the deployment of extra camera brings high computational complexity. To reduce the computational burden, a fast nearest neighbor feature point extraction algorithm (FNNF) is proposed. The proposed method increases the speed of feature points extraction by hundreds of times over the traditional pixel-by-pixel searching method. The modified NIR multi-camera calibration method and 3D reconstruction algorithm further improve the tracking accuracy. Experimental results show that the calibration accuracy of the NIR camera can reach 0.02%, positioning accuracy of markers can reach 0.0240 mm, and dynamic tracking accuracy can reach 0.0938 mm. OTS can be adopted in high-precision dynamic tracking.


2020 ◽  
Vol 31 (01) ◽  
pp. 040-049 ◽  
Author(s):  
Robert W. Koch ◽  
Hasan Saleh ◽  
Paula Folkeard ◽  
Sheila Moodie ◽  
Conner Janeteas ◽  
...  

AbstractProbe-tube placement is a necessary step in hearing aid verification which needs ample hands-on experience and confidence before performing in clinic. To improve the methods of training in probe-tube placement, a manikin-based training simulator was developed consisting of a 3D-printed head, a flexible silicone ear, and a mounted optical tracking system. The system is designed to provide feedback to the user on the depth and orientation of the probe tube, and the time required to finish the task. Although a previous validation study was performed to determine its realism and teachability with experts, further validation is required before implementation into educational settings.This study aimed to examine the skill transference of a newly updated probe-tube placement training simulator to determine if skills learned on this simulator successfully translate to clinical scenarios.All participants underwent a pretest in which they were evaluated while performing a probe-tube placement and real-ear-to-coupler difference (RECD) measurement on a volunteer. Participants were randomized into one of two groups: the simulator group or the control group. During a two-week training period, all participants practiced their probe-tube placement according to their randomly assigned group. After two weeks, each participant completed a probe-tube placement on the same volunteer as a posttest scenario.Twenty-five novice graduate-level student clinicians.Participants completed a self-efficacy questionnaire and an expert observer completed a questionnaire evaluating each participant’s performance during the pre- and posttest sessions. RECD measurements were taken after placing the probe tube and foam tip in the volunteer’s ear. Questionnaire results were analyzed through nonparametric t-tests and analysis of variance, whereas RECD results were analyzed using a nonlinear mixed model method.Results suggested students in the simulator group were less likely to contact the tympanic membrane when placing a probe tube, appeared more confident, and had better use of the occluding foam tip, resulting in more improved RECD measurements.The improved outcomes for trainees in the simulator group suggest that supplementing traditional training with the simulator provides useful benefits for the trainees, thereby encouraging its usage and implementation in educational settings.


Sign in / Sign up

Export Citation Format

Share Document