scholarly journals Intelligent system for improving dosage control

2017 ◽  
Vol 39 (1) ◽  
pp. 33 ◽  
Author(s):  
Fabio Cosme Rodrigues dos Santos ◽  
André Felipe Henriques Librantz ◽  
Cleber Gustavo Dias ◽  
Sheila Gozzo Rodrigues

Coagulation is one of the most important processes in a drinking-water treatment plant, and it is applied to destabilize impurities in water for the subsequent flocculation stage. Several techniques are currently used in the water industry to determine the best dosage of the coagulant, such as the jar-test method, zeta potential measurements, artificial intelligence methods, comprising neural networks, fuzzy and expert systems, and the combination of the above-mentioned techniques to help operators and engineers in the water treatment process. Current paper presents an artificial neural network approach to evaluate optimum coagulant dosage for various scenarios in raw water quality, using parameters such as raw water color, raw water turbidity, clarified and filtered water turbidity and a calculated Dose Rate to provide the best performance in the filtration process. Another feature in current approach is the use of a backpropagation neural network method to estimate the best coagulant dosage simultaneously at two points of the water treatment plant. Simulation results were compared to the current dosage rate and showed that the proposed system may reduce costs of raw material in water treatment plant. 

2000 ◽  
Vol 42 (3-4) ◽  
pp. 403-408 ◽  
Author(s):  
R.-F. Yu ◽  
S.-F. Kang ◽  
S.-L. Liaw ◽  
M.-c. Chen

Coagulant dosing is one of the major operation costs in water treatment plant, and conventional control of this process for most plants is generally determined by the jar test. However, this method can only provide periodic information and is difficult to apply to automatic control. This paper presents the feasibility of applying artificial neural network (ANN) to automatically control the coagulant dosing in water treatment plant. Five on-line monitoring variables including turbidity (NTUin), pH (pHin) and conductivity (Conin) in raw water, effluent turbidity (NTUout) of settling tank, and alum dosage (Dos) were used to build the coagulant dosing prediction model. Three methods including regression model, time series model and ANN models were used to predict alum dosage. According to the result of this study, the regression model performed a poor prediction on coagulant dosage. Both time-series and ANN models performed precise prediction results of dosage. The ANN model with ahead coagulant dosage performed the best prediction of alum dosage with a R2 of 0.97 (RMS=0.016), very low average predicted error of 0.75 mg/L of alum were also found in the ANN model. Consequently, the application of ANN model to control the coagulant dosing is feasible in water treatment.


2021 ◽  
Vol 11 (3) ◽  
pp. 19-27
Author(s):  
Ali Salim Abd Al-Hussein

The aim of this paper is to explain the advantages of using sulfuric acid in Qarmat Ali water treatment plant belong to Basrah Oil Company, which produces water for injection into the Rumaila reservoirs. Sulfuric acid is a strong acid providing rapid and effective pH reduction. Maintaining the coagulation pH within the optimum value (6.4) by inject specific value of sulfuric acid to RAW water enhances the clarification performances by reducing the clarified water turbidity to minimum value (5.1). It was preferable for  operating at a pH below the saturation pH to prevent the precipitation of minerals such as calcium carbonate which are contributing to blocking the surface filters installed downstream (auto back wash filters) and The clarifiers that cause increased the feed from 500 MBD  to 1000 MBD. With a fast and rapid dissociation in Water, Sulfuric acid is an effective and practical way to lower the pH on Qarmat Ali plant which producing in excess of 1,000MBD of export water.


2019 ◽  
Vol 19 (6) ◽  
pp. 1579-1586 ◽  
Author(s):  
Xiang-Ren Zhou ◽  
Yi-Li Lin ◽  
Tian-Yang Zhang ◽  
Bin Xu ◽  
Wen-Hai Chu ◽  
...  

Abstract The objective of this research was to study the occurrence and seasonal variations of disinfection by-products (DBPs), including traditional carbonaceous and emerging nitrogenous DBPs, in a full-scale drinking water treatment plant (DWTP) for nearly 2 years. The removal efficiencies of each DBP through the treatment processes were also investigated. This DWTP takes raw water from the Yangtze River in East China. The quality of the raw water used in this DWTP varied with different seasons. The results suggested that DBP concentrations of the finished water were higher in spring (82.33 ± 15.12 μg/L) and summer (117.29 ± 9.94 μg/L) with higher dissolved organic carbon (DOC) levels, but lower in autumn (41.10 ± 5.82 μg/L) and winter (78.47 ± 2.74 μg/L) with lower DOC levels. Due to the increase of bromide concentration in spring and winter, more toxic brominated DBPs increased obviously and took up a greater proportion. In this DWTP, DBP concentrations increased dramatically after pre-chlorination, especially in summer. It is noteworthy that the removal of DBPs during the subsequent treatment was more obvious in spring than in the other three seasons because the pH value is more beneficial to coagulation in spring.


2007 ◽  
Vol 7 (15) ◽  
pp. 2006-2010 ◽  
Author(s):  
Duduku Krishnaiah ◽  
Siva Kumar Kumaresan . ◽  
Matthew Isidore . ◽  
Rosalam Sarbatly .

2011 ◽  
Vol 64 (7) ◽  
pp. 1419-1427 ◽  
Author(s):  
Zahiruddin Khan ◽  
Rahimuddin Farooqi

Effective water treatment is the prime goal of every water treatment facility. Chakwal Water Treatment Plant in Pakistan has been treating high-turbidity surface water through crude coagulation, sedimentation and slow sand filtration since the early 1980s. The process has always been tedious in terms of high coagulant dosage, large volumes of sludge and short filter runs especially after wet spells. A laboratory-scale study was conducted to see if roughing filtration, as the pre-treatment process, would help in reducing coagulant dose and sludge volume and improving effluent quality. Results indicated that up-flow rouging filtration with media grades decreasing in the direction of flow could reduce wet weather raw water turbidity (by more than 90%) and coagulant dose. Overall, the plant could save over US $54,000 annually in terms of coagulant cost only. Longer filter runs, improved product water quality leading to lower chlorine dose requirement, would be additional benefits.


2018 ◽  
Vol 1 (1) ◽  
pp. 29 ◽  
Author(s):  
Harissa Gustinawati

Water Treatment Plant (IPA) capacity of 50 liters per second in the district Outer City Jambi Jambi Muaro use raw water source Batang Hari River. This installation was built in 2012 and was completed in late 2012. Air processed IPA Foreign Cities Jambi distributed to 12 regions located in the district of Jambi Outer City (Mendalo). Processing unit which exist in the IPA IPA is based prototype project using raw water source located Musi River in South Sumatra. The technical specifications references drinking water treatment plant should use the applicable standard is ISO 6774 in 2008 regarding the procedure of planning unit package water treatment plant and the literature regarding the design of IPA. There are differences between the dimensions of the design criteria based on ISO 6774-2008 with the existing dimensions of the IPA unit. Some of the units are not in accordance with design specifications. Affixing process chemicals do without testing it first, so it is not known optimal dose of the chemicals needed. This study aims to evaluate and optimize the design of the IPA unit Jambi existing State Affairs with the technical specifications of ISO 6774 in 2008 regarding the procedure of planning unit package water treatment plant and the literature regarding the design of IPA.Keywords :    Evaluation, Water Treatment Plant (IPA), ISO 6774-2008, WTP Optimization


Sign in / Sign up

Export Citation Format

Share Document