Static Loading Investigation on Well Cover of Reactive Powder Concrete

Author(s):  
Feng Xing ◽  
Liang Peng Deng ◽  
Zheng Liang Cao ◽  
Li Dong Huang
Author(s):  
Mohammad Makki Abbass Bilal ◽  
Mohamad Adnan Mohamad

Many types of loading the structure must sustain in addition to dead and live loads according to the function of structural element type that must be taken in analysis.  Dynamic resistance to loading of reinforced concrete slabs using self-compact reactive powder concrete, with different boundary conditions at the sides in addition of static loading was studied. The reinforced concrete slabs were designed under static load according to ACI-318R-2014 and then the adequacy was checked under harmonic dynamic loading. The static loading consists of dead load and residential live load considering according to ASCE-07-2010. Modeling analysis was performed to determine the eigenvalues and eigenvectors values and then frequency response analyses of the slab by finite elements method that adopted for analysis. The results indicated that in case of self-compacted reactive powder concrete rather than normal concrete gave deflection less and also there was a different result of deflection according the type of slab boundary condition supports.


2006 ◽  
Vol 302-303 ◽  
pp. 556-560
Author(s):  
Feng Xing ◽  
Liang Peng Deng ◽  
Zheng Liang Cao ◽  
Li Dong Huang

Reactive powder concrete (RPC), which is a new cement-based composite material with ultra-high strength, low-brittleness, excellent durability, is adopted to make well covers. In addition, static loading tests of the well covers are carried out. The test results show that the loading capacity of the RPC well covers can meet the requirements for different situations, such as the special roads, the city motorway, footway, various parking places, etc.


2020 ◽  
Vol 62 (9) ◽  
pp. 951-956
Author(s):  
Luo Xuguo ◽  
Tan Zheng Long ◽  
Y. Frank Chen

2012 ◽  
Vol 568 ◽  
pp. 39-42
Author(s):  
Yu Zhuo Jia ◽  
Li Lin

SAP2000 structural analysis software is used to designed two of 500kV partially prestressed reactive powder concrete pole cross arm; moreover, poles of the two cross arm program have been compared. The results show that the triangular truss cross arm has good mechanical properties, improving the main mate’rial of the stress state, the pole reduced height 10m, by the analysis of the structure shows, this cross arm has higher reliability under the operating conditions, which can be used in 500kV transmission line; from economic and technical performance, the pole cost of this program is greatly reduced, while speeding up the construction progress and improving the comprehensive benefits of the poles in the transmission line.


2013 ◽  
Vol 671-674 ◽  
pp. 1761-1765
Author(s):  
Yong Liu ◽  
Chun Ming Song ◽  
Song Lin Yue

In order to get mechanical properties ,some RPC samples with 5% steel fiber are tested, many groups data were obtained such as compressive strength, shear strength and fracture toughness. And a group of tests on RPC with 5% steel-fiber under penetration were also conducted to validate the performance to impact. The penetration tests are carried out by the semi-AP projectiles with the diameter of 57 mm and earth penetrators with the diameter of 80 mm, and velocities of the two kinds of projectiles are 300~600 m/s and 800~900 m/s, respectively. By contrast between the experimental data and the calculation results of C30 reinforced concrete by using experiential formula under penetration, it shows that the resistance of steel-fiber RPC to penetration is 3 times as that of general C30 reinforced concrete.


Sign in / Sign up