Frost Resistance of Steel Fiber Reinforced Micro-Expansive Concrete Filled Steel Tube

2012 ◽  
Vol 204-208 ◽  
pp. 3956-3960 ◽  
Author(s):  
Ting Min Mou ◽  
Xiao Jun Zhou ◽  
Bi Kun Fan ◽  
Qing Jun Ding

Abstract. This investigation was done based on the concrete filled steel tube (CFST) winter construction of Ganhaizi Bridge. Steel fiber reinforced micro-expansive concrete (SREC) with high frost-resistance ability, excellent fluidity and good self-compacting ability was prepared. Strength development mode under low temperature was illustrated. Scanning electron microscope (SEM) was used to analyze the morphology features of hydration products at the age of 28 days. It was confirmed that when the content of sodium nitrite was 0.4%, SREC did not frost under -5°C. In addition, SEM showed that ettringite and CSH gels were in good growth state, and concrete structure was very dense. Furthermore, 6 CFST short columns were poured in the winter construction site of Ganhaizi Bridge, and another 27 short columns were cut from emitting slurry pipe filling with concrete emitted from main girder. The bearing capacity of all the CFST specimens was tested when the environment temperature rose to about 25°C. The experimental results indicated that the mechanical performances of CFST specimens with anti-freezing admixture did not exhibit degradation when cast in site under a low temperature and tested at 24.3°C. The concrete presented in this research substantially met the need of Ganhaizi Bridge CFST construction in winter.

2012 ◽  
Vol 204-208 ◽  
pp. 4083-4087 ◽  
Author(s):  
Xiao Jun Zhou ◽  
Ting Min Mou ◽  
Bi Kun Fan ◽  
Qing Jun Ding

Abstract: Steel fiber reinforced micro-expansive concrete (SREC) with excellent fluidity, high resistance to segregation and good self-compacting ability was prepared. Compressive test, splitting tensile test and flexural test were performed. Self-developed confined expansion test instrument of concrete filled steel tube (CFST) was used to evaluate the deformation behaviors of SREC confined in the steel tube. The structure behavior of steel fiber reinforced micro-expansive concrete filled steel tube (SECFST) was investigated through 12 short column specimens. Expansion agent invariant and steel fiber contents were the dominant variables. The results showed that when compared to common micro-expansive concrete, the splitting tensile and flexural strength of SREC were increased by 78.0% and 64.7%, respectively. When the expansion agent amount was 40kg and volume fraction of steel fiber was less than 1%, SECFST exhibited stable expansive deformation. The use of steel fiber combined with expansion agent moderately improved the yield load and ultimate load of CFST.


2021 ◽  
pp. 136943322110093
Author(s):  
Zhenzhen Liu ◽  
Yiyan Lu ◽  
Shan Li ◽  
Jiancong Liao

A comprehensive study of the shear characteristics of steel fiber reinforced recycled concrete-filled steel tube (SRCFST) columns is conducted. 50 CFST stub columns are tested with the variables of steel tube diameter-thickness ratio ( D/t), shear span-to-depth ratio (λ), axial compression ratio ( n), and concrete mix. Two types of cements, three recycled aggregate percentages, three water-cement ratios, and three steel fiber contents are considered in design of concrete mixes. The experimental results show that SRCFST columns present the coincident shear behavior of the ordinary CFST columns. As λ is increased, shear resistance shows a downtrend, while the flexural strength presents an increasing trend. Imposing axial compression or thickening steel tube contributes to an adequate safety margin in plastic period. Based on the contributions superposition method, a predicted model of the shear capacity of SRCFST columns is proposed in consideration of shear-span ratio, axial compression, and self-stress.


2012 ◽  
Vol 424-425 ◽  
pp. 1228-1232
Author(s):  
Su Qi ◽  
Jin Xing He ◽  
Nian Liu ◽  
Wei Wu

There are changes in material properties of concrete when compared axially loaded short columns with micro-expansive concrete filled steel tube with axially loaded short columns with common reinforced concrete and these changes will inevitably lead to the change of axially loaded short columns with micro-expansive concrete filled steel tube in performance. It is impossible to fully use the existing research results of axially loaded short columns with common reinforced concrete; therefore, it is necessary to do experimental research on the working performance of axially loaded short columns with micro-expansive concrete filled steel tube. This paper studied the hydration heat, self-stress and failure load according to the test conditions of the 15 axially loaded short columns with micro-expansive concrete filled steel tube specimen; determined the optimum mix amount of axially loaded short columns with micro-expansive concrete filled steel tube and proposed the increase rate of ultimate failure load of axially loaded short columns with micro-expansive concrete filled steel tube compared with axially loaded short columns with common reinforced concrete. This will facilitate the practical application of engineering.


2010 ◽  
Vol 163-167 ◽  
pp. 596-599 ◽  
Author(s):  
Yi Yan Lu ◽  
Shan Li ◽  
Juan Chen

Many in-fill materials are used to improve ductility of concrete filled steel tube (CFST), due to meeting need for a change of seismic design perspective form the previous emphasis on structural strength to emphasis on structural ductility and energy absorption. Among the various in-fill materials, steel fiber is gaining attention in the CFST column. This paper investigates effect of volume fractions of steel fiber to concrete on the behavior of short steel fiber reinforced concrete filled steel tube columns under axial compression. The volume fractions of steel fiber to concrete are 0.6, 0.9 and 1.2%. The results indicate that steel fiber reinforced concrete filled steel tube columns appears to have a significant increasing trend in ductility, and have a slight increasing trend in load capacity with volume fraction of steel fiber to concrete increasing. The failure mode of the composite columns is similar with that of CFST.


2013 ◽  
Vol 790 ◽  
pp. 181-184
Author(s):  
Hai Lun Tong ◽  
Tian Hong Wang ◽  
Jian Qi Lu ◽  
Xin Tang Wang

The post-fire axial compressive behavior of a set of steel fiber reinforced ceramsite concrete filled steel tubular short columns (noted as SFCC-SSC) was experimentally studied. Effect of the maximum value of fire response temperatures of the specimens and some parameters on the axial compression performance of the specimens was especially discussed. The results show that the surface of the steel tubes after fire presented dark red for 700°Cof furnace temperature and orange red for 900°C, and there was no obvious descending segment in post-fire load-displacement curves of the most specimens subjected to fire load. It was concluded that the axial bearing capacity of the specimens aftersuffering the furnace temperature of 900°C is much less than that of the specimens not subjected to fire load, and the volume of steel fiber of 0.5% of has the greatest effect on post-fire bearing capacity of specimens of SFCC-SSC.


2011 ◽  
Vol 368-373 ◽  
pp. 357-360
Author(s):  
Lei Jiang ◽  
Di Tao Niu ◽  
Min Bai

Based on the fast freeze-thaw test in 3.5% NaCl solution, the frost resistance of steel fiber reinforced concrete (SFRC) was studied in this paper. On the basis of scanning electron microscope (SEM) and mercury intrusion method, the microstructure and pore structure of SFRC was analysed. The reinforced mechanism of SFRC under the cooperation of freeze-thaw and NaCl solution was discussed. The test results show that adding appropriate amount of steel fibers into concrete can reduce the pore porosity and improve the compactness of concrete. The effects of steel fiber with proper volume fraction can inhibit the peeling of the concrete and reduce its damage rate. The volume of steel fiber on the frost-resisting property of SFRC is obvious.


Sign in / Sign up

Export Citation Format

Share Document