Nonlinear Seismic Response Analysis of Parallel Base-Isolated System

2012 ◽  
Vol 256-259 ◽  
pp. 2254-2257
Author(s):  
Q. Rong

Based on the bilinear hysteretic model, the elastic-plastic time history analysis of single mass point for parallel base isolation system is carried out. The approximate treatment method of the inflexion point is introduced and the formula of each energy consumption for parallel base-isolated structure is given. Through an engineering example, the time history curve of each energy dissipation for parallel base-isolated system is drawn, and the isolation effect is given.

2012 ◽  
Vol 204-208 ◽  
pp. 3592-3595
Author(s):  
Xiao Song ◽  
Peng Li ◽  
Guang Sheng Xu

Design process and the nonlinear time history analysis for base isolation system is performed in this paper. The results show that the earthquake acceleration and displacement response of isolated structure can be significantly reduced. Application of the isolation system to improve the seismic capacity of the structure,can effectively reduce the response of upper structure of in earthquake.


2012 ◽  
Vol 234 ◽  
pp. 96-101 ◽  
Author(s):  
Donato Cancellara ◽  
Fabio de Angelis

In the present work we have analyzed a particular base isolation system for the seismic protection of a multi-storey reinforced concrete (RC) building. The viscous dampers and friction sliders are the devices adopted in parallel for realizing the base isolation system. The base isolation structure has been designed and verified according to European seismic code EC8 and by considering for the friction sliders the influence of the sliding velocity on the value of the friction coefficient. A dynamic nonlinear analysis for a three-dimensional base isolated structure has been performed. Recorded accelerograms for bi-directional ground motions have been used which comply with the requirements imposed by EC8 for the representation of a seismic action in a time history analysis. In this paper a comparative analysis is presented between the base isolated structure with the described hybrid base isolation system and the traditional fixed base structure.


2013 ◽  
Vol 639-640 ◽  
pp. 896-900
Author(s):  
Ying Yuan ◽  
Ai Hong Zhou ◽  
Yan Li Gao

Different friction bearing ratios have effects on the base isolation property of parallel composite isolation system subjected to the seismic excitation. In order to deeply investigate how the friction bearing ratio affect the isolation property, the numerical simulation was carried out by the time-history analysis method, in which the seismic response of parallel composite isolation system with different friction bearing ratios under different acceleration peak values were calculated. Then, the effects of different friction bearing ratios on the base maximum shear coefficients and base maximum displacements; the hysteretic characteristics and nonlinear properties were analyzed and discussed. The results show that, for the parallel composite isolation system, friction bearing ratio is a key factor affecting the isolation property and the nonlinear properties are tightly related to the friction bearing ratio and acceleration peak values.


2012 ◽  
Vol 602-604 ◽  
pp. 1546-1554
Author(s):  
Donato Cancellara ◽  
Fabio de Angelis ◽  
Mario Pasquino

In this paper we have analyzed the influence of the strain hardening behavior of High Damping Rubber Bearings (HDRBs) adopted for a base isolation system of a Reinforced Concrete (RC) isolated structure. For the modeling of the rubber isolators we have adopted an evolution of the Bouc-Wen’s hysteretic model taking into account the incremental hardening effect which appears when the shear strain of the HDRB exceeds the limit value around 100% usually adopted in design practice. The incremental hardening effect is sometimes neglected in the design but it is an important aspect because it ensures a seismic protection of the base isolated structure also in presence of exceptional seismic events for intensity or frequency content. In this paper we have highlighted the significant influence of this phenomenon in the seismic response of the isolated structure by reporting the cyclic behavior of a HDRB respectively neglecting and considering this aspect.


2020 ◽  
Vol 10 (1) ◽  
pp. 45-54
Author(s):  
Soroush Kherad ◽  
Mahmood Hosseini ◽  
Mehrtash Motamedi

AbstractUsing seesaw structural system equipped with energy dissipating devices has been considered as a low-cost and low-tech way for creation of earthquake-resilient buildings. In this paper by considering three groups of multi-story buildings, including conventional buildings, LRB-based isolated buildings and building with seesaw structure, equipped with a newly introduced type of structural fuses, their seismic performances have been compared through nonlinear time history analyses (NLTHA). The employed fuses in seesaw buildings are a specific type of yielding plate dampers, called Multiple Curved Yielding Plate Energy Dissipater (MCYPED), installed at the bottom of the all circumferential columns of the lowest story of the building. To show the efficiency of the proposed seesaw system in comparison with other two mentioned groups, first, by finite element modeling, verified by experimental results, the initial and secondary stiffness values as well as the yielding and ultimate strengths of the MCYPEDs have been obtained to be modeled by multi-linear plastic springs in the seesaw buildings. Then, a series of NLTHA have been performed on the three groups of buildings by using a set of selected earthquakes. The compared responses include roof displacement and acceleration, base shear, inter-story drift and finally plastic hinges (PHs) formed in the building’s structures. Results show that the proposed seesaw building equipped with MCYPEDs not only results in lower seismic demand, similar to base isolation system, but also leads to remarkable energy dissipation capacity in the building structure at base level, so that the building structure remains basically elastic, and does not need any major repair work, even after large earthquakes, contrary to the conventional building which need to be demolished after the earthquake.


10.29007/pvzx ◽  
2018 ◽  
Author(s):  
Kishan Bhojani ◽  
Vishal Patel ◽  
Snehal Mevada

During the life span of structure there may be an effect of vibration. Due to vibration there may be major or minor damage in building. Base isolation is best method to reduce the seismic response of the structure. This paper gives idea about base isolation system which can be used in multi-story building to reduce seismic response of the structure. This paper represents the initialize study of dynamic parameter like effective damping for four earthquake time history. In this paper the optimum effective damping has been found out under the effect of Loma Prieta earthquake time history. The parametric study has been conducted to evaluate the effect on maximum displacement, maximum acceleration, maximum base shear in bare frame and frame with isolator.


2019 ◽  
Vol 8 (4) ◽  
pp. 12336-12339

In the present paper base isolation system is analyzed and its seismic behavior is investigated using U-shaped steel dampers as an isolator by placing it at the bottom of the structure. It is the most popular way of protecting the structure using control techniques for earthquake ground motion. The dampers significantly reduced damage factors such as displacement and drift. To reduce structural response to external forces, which can be accomplished through the use of special protective systems. So to prevent these damages, seismic isolation technique can be used for newly constructed structures. The time history analysis of the time domain on this structure is conducted by using SAP2000 software


2014 ◽  
Vol 2014 ◽  
pp. 1-13 ◽  
Author(s):  
Stefano Sorace ◽  
Gloria Terenzi

The analysis and design of a multiple residential building, seismically protected by a base isolation system incorporating double friction pendulum sliders as protective devices, are presented in the paper. The building, situated in the suburban area of Florence, is composed of four independent reinforced concrete framed structures, mutually separated by three thermal expansion joints. The plan is L-shaped, with dimensions of about 75 m in the longitudinal direction and about 30 m along the longest side of the transversal direction. These characteristics identify the structure as the largest example of a base-isolated “artificial ground” ever built in Italy. The base isolation solution guarantees lower costs, a much greater performance, and a finer architectural look, as compared to a conventional fixed-base antiseismic design. The characteristics of the building and the isolators, the mechanical properties and the experimental characterization campaign and preliminary sizing carried out on the latter, and the nonlinear time-history design and performance assessment analyses developed on the base isolated building are reported in this paper, along with details about the installation of the isolators and the plants and highlights of the construction works.


Sign in / Sign up

Export Citation Format