Seismic Isolation Design of Multistory Building

2012 ◽  
Vol 204-208 ◽  
pp. 3592-3595
Author(s):  
Xiao Song ◽  
Peng Li ◽  
Guang Sheng Xu

Design process and the nonlinear time history analysis for base isolation system is performed in this paper. The results show that the earthquake acceleration and displacement response of isolated structure can be significantly reduced. Application of the isolation system to improve the seismic capacity of the structure,can effectively reduce the response of upper structure of in earthquake.

2014 ◽  
Vol 578-579 ◽  
pp. 1361-1365
Author(s):  
Lin Liu ◽  
Xuan Min Li ◽  
Wei Tian

Friction Pendulum Systems have been used as base isolation systems for both new construction and retrofit around the world. This paper presented its implementation in an office building located in Shanghai. To evaluate its impact on seismic performance of the retrofitted structure, models are needed to capture the intricate nonlinear behavior of both structural components and isolator elements. Nonlinear time history analysis of the building for the original and retrofitted cases was conducted to assess the efficiency of the isolation system at the high earthquake level. The numerical results indicate that the retrofitted structure experiences significantly less damage and less deformation due to the shake isolation and energy dissipation through the isolators.


2021 ◽  
Vol 309 ◽  
pp. 01136
Author(s):  
Siripuram Vamshisheela ◽  
Atulkumar Manchalwar

In this work the performance of U-Shaped Steel Isolator is evaluated for a 5-story building subjected to seismic and blast vibrations. The structure is analysed using SAP 2000 software and a nonlinear time history analysis is carried out. The effectiveness of using base isolation is studied by comparing the structural responses of the building with isolator and without isolator and noticeable difference was observed. As the U-Shaped isolator absorbs the energy in all directions, it effectively controls the structural responses. In this study, the building is subjected to four different seismic and four different blast induced ground motions. It was observed that by the use of supplementary energy device there is reduction in top story acceleration, base shear and less deformation in the structure. This study concludes that the use of isolator has been effective in minimizing structural responses.


2020 ◽  
Vol 10 (1) ◽  
pp. 45-54
Author(s):  
Soroush Kherad ◽  
Mahmood Hosseini ◽  
Mehrtash Motamedi

AbstractUsing seesaw structural system equipped with energy dissipating devices has been considered as a low-cost and low-tech way for creation of earthquake-resilient buildings. In this paper by considering three groups of multi-story buildings, including conventional buildings, LRB-based isolated buildings and building with seesaw structure, equipped with a newly introduced type of structural fuses, their seismic performances have been compared through nonlinear time history analyses (NLTHA). The employed fuses in seesaw buildings are a specific type of yielding plate dampers, called Multiple Curved Yielding Plate Energy Dissipater (MCYPED), installed at the bottom of the all circumferential columns of the lowest story of the building. To show the efficiency of the proposed seesaw system in comparison with other two mentioned groups, first, by finite element modeling, verified by experimental results, the initial and secondary stiffness values as well as the yielding and ultimate strengths of the MCYPEDs have been obtained to be modeled by multi-linear plastic springs in the seesaw buildings. Then, a series of NLTHA have been performed on the three groups of buildings by using a set of selected earthquakes. The compared responses include roof displacement and acceleration, base shear, inter-story drift and finally plastic hinges (PHs) formed in the building’s structures. Results show that the proposed seesaw building equipped with MCYPEDs not only results in lower seismic demand, similar to base isolation system, but also leads to remarkable energy dissipation capacity in the building structure at base level, so that the building structure remains basically elastic, and does not need any major repair work, even after large earthquakes, contrary to the conventional building which need to be demolished after the earthquake.


2019 ◽  
Vol 8 (4) ◽  
pp. 12336-12339

In the present paper base isolation system is analyzed and its seismic behavior is investigated using U-shaped steel dampers as an isolator by placing it at the bottom of the structure. It is the most popular way of protecting the structure using control techniques for earthquake ground motion. The dampers significantly reduced damage factors such as displacement and drift. To reduce structural response to external forces, which can be accomplished through the use of special protective systems. So to prevent these damages, seismic isolation technique can be used for newly constructed structures. The time history analysis of the time domain on this structure is conducted by using SAP2000 software


2012 ◽  
Vol 204-208 ◽  
pp. 2658-2661 ◽  
Author(s):  
Biao Wei ◽  
Shan Shan Li

As to improve bridges’ seismic performance, horizontal earthquake was isolated at the bottom of piers. With one pier system as the object of study, adopting nonlinear time history analysis analyzed the un-isolation system, the traditional isolation system and the new isolation system’s seismic performance especially when the actual earthquake was different from the design earthquake, in which the new isolation system was based on rolling balls. Results shows, as for the new isolation system, the internal force is independent of earthquake accelerations and earthquake periods, therefore, sympathetic vibration will not exist, and the internal force is always too small to destroy the system.


2012 ◽  
Vol 256-259 ◽  
pp. 2254-2257
Author(s):  
Q. Rong

Based on the bilinear hysteretic model, the elastic-plastic time history analysis of single mass point for parallel base isolation system is carried out. The approximate treatment method of the inflexion point is introduced and the formula of each energy consumption for parallel base-isolated structure is given. Through an engineering example, the time history curve of each energy dissipation for parallel base-isolated system is drawn, and the isolation effect is given.


2021 ◽  
Vol 248 ◽  
pp. 01001
Author(s):  
Shu-jiang Jiang ◽  
Shun-zhong Yao ◽  
De-wen Liu

This paper uses SAP2000 finite element software to perform nonlinear time history analysis of nine structural systems, and compares the period, total floor displacement, base shear force, vertex displacement, and top acceleration of the structure under the action of an 8-degree rare earthquake. The research results show that seismic isolation and damping technology can effectively reduce the impact of earthquakes on structures.


2014 ◽  
Vol 2014 ◽  
pp. 1-13 ◽  
Author(s):  
Stefano Sorace ◽  
Gloria Terenzi

The analysis and design of a multiple residential building, seismically protected by a base isolation system incorporating double friction pendulum sliders as protective devices, are presented in the paper. The building, situated in the suburban area of Florence, is composed of four independent reinforced concrete framed structures, mutually separated by three thermal expansion joints. The plan is L-shaped, with dimensions of about 75 m in the longitudinal direction and about 30 m along the longest side of the transversal direction. These characteristics identify the structure as the largest example of a base-isolated “artificial ground” ever built in Italy. The base isolation solution guarantees lower costs, a much greater performance, and a finer architectural look, as compared to a conventional fixed-base antiseismic design. The characteristics of the building and the isolators, the mechanical properties and the experimental characterization campaign and preliminary sizing carried out on the latter, and the nonlinear time-history design and performance assessment analyses developed on the base isolated building are reported in this paper, along with details about the installation of the isolators and the plants and highlights of the construction works.


2014 ◽  
Vol 587-589 ◽  
pp. 1377-1380
Author(s):  
Feng Miao

Larger displacement and inter-force response of the structure will be produced when self-anchored cable-stayed suspension bridge in longitudinal earthquake. For the isolation system of self-anchored cable-stayed suspension bridge, whose main tower is set the lead core rubber isolation bearing. This essay does the nonlinear time history analysis under the longitudinal earthquake about the isolation system when the viscous damper is put in different location. Analysis results show that inter-force and displacement of control section and control node are reduced greatly in hybrid vibration control. The result is obvious when the viscous damper is set both in the main tower, the side block and only in the main tower.


Sign in / Sign up

Export Citation Format

Share Document