Operation Analysis of the Rail Transit Stations Energy-Saving Air-Conditioning System Based on Petri Nets

2014 ◽  
Vol 513-517 ◽  
pp. 3564-3567
Author(s):  
Bing Xu ◽  
Zhong Jin Shi ◽  
Bao Guo Zheng ◽  
Xue Han Zhu ◽  
Yi Huan Hui

In order to fully research and describe the dynamics of the energy consumption of rail transportation equipment operation, this chapter will Petri nets Establishment and analysis of the environmental control system air-conditioning power consumption model, so as to deepen the understanding of the principle of the energy consumption of devices running depth grasp of energy consumption the operational features of the equipment, take appropriate and effective energy-saving measures.

Symmetry ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 344
Author(s):  
Alejandro Humberto García Ruiz ◽  
Salvador Ibarra Martínez ◽  
José Antonio Castán Rocha ◽  
Jesús David Terán Villanueva ◽  
Julio Laria Menchaca ◽  
...  

Electricity is one of the most important resources for the growth and sustainability of the population. This paper assesses the energy consumption and user satisfaction of a simulated air conditioning system controlled with two different optimization algorithms. The algorithms are a genetic algorithm (GA), implemented from the state of the art, and a non-dominated sorting genetic algorithm II (NSGA II) proposed in this paper; these algorithms control an air conditioning system considering user preferences. It is worth noting that we made several modifications to the objective function’s definition to make it more robust. The energy-saving optimization is essential to reduce CO2 emissions and economic costs; on the other hand, it is desirable for the user to feel comfortable, yet it will entail a higher energy consumption. Thus, we integrate user preferences with energy-saving on a single weighted function and a Pareto bi-objective problem to increase user satisfaction and decrease electrical energy consumption. To assess the experimentation, we constructed a simulator by training a backpropagation neural network with real data from a laboratory’s air conditioning system. According to the results, we conclude that NSGA II provides better results than the state of the art (GA) regarding user preferences and energy-saving.


2018 ◽  
Vol 38 ◽  
pp. 04012
Author(s):  
Sai Feng Xu ◽  
Xing Lin Yang ◽  
Zou Ying Le

For ocean-going vessels sailing in different areas on the sea, the change of external environment factors will cause frequent changes in load, traditional ship air-conditioning system is usually designed with a fixed cooling capacity, this design method causes serious waste of resources. A new type of sea-based air conditioning system is proposed in this paper, which uses the sea-based source heat pump system, combined with variable air volume, variable water technology. The multifunctional cabins’ dynamic loads for a ship navigating in a typical Eurasian route were calculated based on Simulink. The model can predict changes in full voyage load. Based on the simulation model, the effects of variable air volume and variable water volume on the energy consumption of the air-conditioning system are analyzed. The results show that: When the VAV is coupled with the VWV, the energy saving rate is 23.2%. Therefore, the application of variable air volume and variable water technology to marine air conditioning systems can achieve economical and energy saving advantages.


2019 ◽  
Vol 17 (1) ◽  
pp. 88
Author(s):  
Herman Nawir ◽  
Kusmanurwira Kusmanurwira ◽  
Alif Firdaus

Abstract In the hotel business, the use of energy is very important, especially in the use of electricity, the portion of usage and allocation of funds for its provision is the largest. It can be seen that equipment such as lights, elevators, refrigerators, laundry, heaters, pumps, to the air conditioning system are some of the dominant tools in operations in the hospitality world. The results of the initial energy audit and detailed audit at the Grand Clarion Hotel Makassar showed that the Energy Consumption Intensity (IKE) is still far from the standard, which is 300 kWh / m2 a year. The building uses the largest amount of electricity in the Grand Clarion Hotel Makassar in Building A, which is in the Guest Room area of the air conditioning unit. The results of the initial energy audit of Energy Consumption Intensity (IKE) electricity were 336.84 kWh / m2 year. Whereas based on the results of a detailed energy audit the electricity consumption intensity (IKE) of electricity is 395.51 kWh / m2 a year. Energy Saving Opportunities (PHE) in this energy audit is to evaluate the AC power in each room and recommend the replacement of lamp types. From the results of the IKE calculation after the application of PHE, it is found that the value is still quite high so that efforts to save must still be done. 


2011 ◽  
Vol 280 ◽  
pp. 71-75
Author(s):  
Zhong Chao Zhao ◽  
Dong Hui Zhang ◽  
Yu Ping Chen

In this paper, the operation mechanism of combined air-conditioning system with temperature and humidity decoupled treatment (CACSTHDT) was presented, and the energy saving potential and economics of CACSTHDT were primarily analyzed through compared with a traditional air-conditioning system. The results indicated that CACSTHDT could save up to 28.64% energy consumption in comparison with a traditional air-conditioning system. The operating cost in one summer only was 71.36% of that cost of traditional air-conditioning system.


2014 ◽  
Vol 672-674 ◽  
pp. 518-521
Author(s):  
Li Fei Song ◽  
Tao Li ◽  
Qi Fen Li ◽  
Lin Hui Zhao ◽  
Xin Zhao ◽  
...  

In this paper, the Unicom's medium-sized IDC room in a city of northern China is the research object for the study. Based on field research of the room refrigeration conditions, data center room air conditioning system is carried out to optimize and for energy conservation research. Through the analytic methods of energy saving-technology, the best energy saving solutions is explored.


2014 ◽  
Vol 493 ◽  
pp. 281-286 ◽  
Author(s):  
Widyastuti ◽  
Ary Bachtiar Krishna Putra ◽  
Ridho Hantoro ◽  
Eky Novianarenti ◽  
Arrad Ghani Safitra

Sepuluh November Institute of Technology (ITS) encourages the ECO Campus program. The program enables ITS to systematically identify, evaluate, manage and improve their environmental performance and practices. One of the program issue is energy saving in building. The energy saving effect of an air-conditioning system retrofit project is analyzed by Energy Conservation Opportunities (ECOs) Method. These ECOs are assessed in terms of their costs and benefits, and an economic comparison to rank the various refrigerants. Finally, an Action Plan is created where certain ECOs are selected for implementation. Civil Engineering Department has a responsibility to design infrastructure and green building concept planning. This department also has the largest energy consumption in this faculty comparing the other department. The energy consumption on this Department is 60829 kWh/month. The value of IKE is 13.39 per month with the largest electrical energy consumption in air-conditioning system is 57% from total consumption. The energy used of air-conditioning sytem is 523.692 kWh. The energy saving opportunities by CFC retrofitting with hydrocarbon can save its power consumption about 20%. It also saving cost and reducing the electricity bill of 1643871.838 IDR/month. The payback period of investment costs of retrofit R-22 to Hydrocarbonis about 13 month.


2014 ◽  
Vol 977 ◽  
pp. 166-169
Author(s):  
Xin Li ◽  
Xin Yu Ma ◽  
Ya Fei Hao

The pharmaceutical industry building adopts the centralized air conditioning system with the characteristics of complicated structure, numerous equipments, relatively concentrated, high level of energy consumption, flexibility larger. In this paper, a clean air conditioning system of freeze-dried powder production workshop at a pharmaceutical company in northern China was been as an example. Energy consumption before and after the use of energy saving technology was been compared. The energy consumption and energy efficiency was been argument. It was a very good reference to other pharmaceutical companies.


2013 ◽  
Vol 712-715 ◽  
pp. 1614-1618
Author(s):  
Jia Jia Ni ◽  
Li Tao ◽  
Yi Jun Wang ◽  
Jin Lei Wu

Through to investigation on present situation of the Changzhou Changrui Hotel air conditioning system energy consumption, by analysis the energy consumption, the power consumption of hotel central air-conditioning system charge 58% of the total electric, accounted for a large proportion. So we should take the necessary measures to reduce the expenses of air conditioning system energy consumption. According to the analysis of data on the survey, we put forward some particular energy-saving measures of central air-conditioning system of the hotel, including strengthening the building envelope insulation, energy saving technology of doors and windows, measures of roof energy saving, setting reasonable indoor temperature, adopting frequency control air-conditioning, reuse waste heat of the central air-conditioning, using the condensation water of central air conditioning to make-up water and reducing temperature of cooling tower , and drying the fresh air independently.


2014 ◽  
Vol 494-495 ◽  
pp. 1674-1677
Author(s):  
Bing Xu ◽  
Fang Hong Yuan ◽  
Bao Guo Zheng ◽  
Zhong Jin Shi ◽  
Yi Huan Hu

This article discusses energy conservation for air conditioning systems in rail transit stations. At first, the paper analyzes the energy consumption condition in the air conditioning systems in rail transit stations. Then, it discusses application of appropriate control strategy for reducing energy consumption. In the end, the paper calculates effiency and amount of the energy saving based on the control strategy.


2012 ◽  
Vol 562-564 ◽  
pp. 1218-1221
Author(s):  
Sheng Hui Guo ◽  
Xue Li Zhu ◽  
Shu Xian Zhu ◽  
Yong Jun Zhu

Building energy research has been focused on the study of improving the efficiency of equipment operation and operating control mode, rather than the management of central air conditioning system terminal. In fact, large amounts of energy can be conserved through that study. And terminal temperature of the central air conditioning with automatic detection is necessary to fulfill the energy-saving with the management of central air conditioning system terminal. An automatic terminal temperature detection of central air conditioning system based on wireless communication mode has been designed. It can transfer data to the monitoring center to provide reference data to fulfill the energy-saving.


Sign in / Sign up

Export Citation Format

Share Document