Theoretical Studies on the Application of Pulsating Heat Pipe in Vapour Compression Refrigeration System

2014 ◽  
Vol 592-594 ◽  
pp. 1801-1806 ◽  
Author(s):  
Rudra Naik ◽  
Linford Pinto ◽  
K. Rama Narasimha ◽  
G. Pundarika

This paper proposes a simplified theoretical model of Pulsating Heat Pipe (PHP) employed in a vapour compression refrigeration system. The model developed is mainly based on well known physical equations and partially based on empirical correlation. The present theoretical investigation of PHP is focused to explore its suitability as a heat exchanger in the condenser of vapour compression refrigeration system. A parametric analysis is carried out to design the vapour compression refrigeration system with PHP as the condenser. The performance of the system is evaluated for different PHP diameters, working fluids, evaporator and condenser temperatures and evaporator and condenser lengths. The effect of super heating and sub cooling the refrigerant are also studied. The results showed an increase in performance of the system at higher evaporator and lower condenser temperatures. The best results are obtained with R-12 as the working fluid. Also there is an increase in the COP of the system due to decrease in pressure drop in the condenser.

2006 ◽  
Vol 17 (1) ◽  
pp. 50-57 ◽  
Author(s):  
A Meyer ◽  
R T R T Dobson

This paper considers the thermal design and the experimental testing of a heat pipe (thermosyphon) heat exchanger for a relatively small commercially available mini-drier. The purpose of the heat exchanger is to recover heat from the moist waste air stream to preheat the fresh incoming air. The working fluid used was R134a and the correlations are given for the evaporator and condenser inside heat transfer coefficients as well as for the maximum heat transfer rate. The theoretical model and computer simulation program used for the thermal design calculations are described. The validity of the as-designed and manufactured heat exchanger coupled to the drier is experimentally verified. The theoretical model accurately predicted the thermal performance and a significant energy savings and a reasonable payback period was achieved.


Energies ◽  
2020 ◽  
Vol 13 (1) ◽  
pp. 269 ◽  
Author(s):  
Kai-Shing Yang ◽  
Ming-Yean Jiang ◽  
Chih-Yung Tseng ◽  
Shih-Kuo Wu ◽  
Jin-Cherng Shyu

In this study, the vertically-oriented pulsating heat pipe (PHP) heat exchangers charged with either water or HFE-7000 in a filling ratio of 35% or 50% were fabricated to exchange the thermal energy between two air streams in a parallel-flow arrangement. Both the effectiveness of the heat exchangers and the thermal resistance of PHP with a size of 132 × 44 × 200 mm, at a specific evaporator temperature ranging from 55 to 100 °C and a specific airflow velocity ranging from 0.5 to 2.0 m/s were estimated. The results show that the heat pipe charged with HFE-7000 in either filling ratio is likely to function as an interconnected array of thermosiphon under all tested conditions because of the unfavorable tube inner diameter, whereas the water-charged PHP possibly creates the pulsating movement of the liquid and vapor slugs once the evaporator temperature is high enough, especially in a filling ratio of 50%. The degradation in the thermal performance of the HFE-7000-charged PHP heat exchanger resulted from the non-condensable gas in the tube became diminished as the evaporator temperature was increased. By examining the effectiveness of the present heat exchangers, it is suggested that water is a suitable working fluid while employing the PHP heat exchanger at an evaporator temperature higher than 70 °C. On the other hand, HFE-7000 is applicable to the PHP used at an evaporator temperature lower than 70 °C.


Author(s):  
Kenneth C. Brown

A remote area power supply using cold thermal storage and wind as the energy source is proposed. The primary objective is to provide a renewable energy remote area power supply with cheaper and more robust storage than lead-acid batteries. The proposal amalgamates a vapour compression refrigeration system with a Rankine cycle engine, both using the same working fluid. A tank of freezing brine acts as the condenser in the Rankine cycle and as the evaporator in the refrigeration cycle but also provides the “energy storage”. Analysis of the system indicates that it is practical and that its performance is comparable with existing battery based systems.


In this investigation of multi heat pipe induced in heat exchanger shows the developments in heat transfer is to improve the efficiency of heat exchangers. Water is used as a heat transfer fluid and acetone is used as a working fluid. Rotameter is set to measure the flow rate of cold water and hot water. To maintain the parameter as experimental setup. Then set the mass flow rate of hot water as 40 LPH, 60LPH, 80 LPH, 100LPH, 120 LPH and mass flow rate of cold water as 20 LPH, 30 LPH, 40 LPH, 50 LPH, and 60 LPH. Then 40 C, 45 ºC, 50 ºC, 55 C, 60 ºC are the temperatures of hot water at inlet are maintained. To find some various physical parameters of Qc , hc , Re ,, Pr , Rth. The maximum effectiveness of the investigation obtained from condition of Thi 60 C, Tci 32 C and 100 LPH mhi, 60 LPH mci the maximum effectiveness attained as 57.25. Then the mhi as 100 LPH, mci as 60 LPH and Thi at 40 C as 37.6%. It shows the effectiveness get increased about 34.3 to the maximum conditions.


2019 ◽  
Vol 8 (4) ◽  
pp. 2704-2712

The refrigerants are usually provided in the conventional refrigeration system despite the fact that, they produce CFCs and HCFCs, which are hazardous to the environment. However, these disadvantages can be overcome using air or inert gas in the thermoacoustic refrigeration system. The present research involves the effect of spacing of parallel plate stack on the performance of thermoacoustic refrigerator (TAR) in terms of temperature difference (∆T). The entire resonator system as well as other structural parts of the refrigerator are fabricated by using PVC to reduce conduction heat loss. Three parallel plate stacks have been used to study the performance of TAR considering different porosity ratios by varying the gap between the parallel plates (0.28 mm, 0.33 mm and 0.38 mm). The parallel plate stacks are fabricated by using aluminium and mylar sheet material and the working fluid used for the experimental study is helium. The experiments have been carried out with different drive ratios ranging from 0.6% to 1.6% with operating frequencies of 200 – 600 Hz. Also the mean operating pressure used for the experiment is 2 to 10 bar and cooling load of 2 to 10W are considered. The ∆T between the hot heat exchanger and cold heat exchanger is recorded using RTDs and Bruel and Kjaer data acquisition system. Experimental results shows that the lowest temperature measured at cold heat exchanger is -2.1 oC by maintaining the hot heat exchanger temperature at about 32 oC. The maximum temperature difference of 32.90 oC is achieved.


Author(s):  
Mitchell P. Hoesing ◽  
Gregory J. Michna

The ongoing development of faster and smaller electronic components has led to a need for new technologies to effectively dissipate waste thermal energy. The pulsating heat pipe (PHP) shows potential to meet this need, due to its high heat flux capacity, simplicity, and low cost. A 20-turn flat plate PHP was integrated into an aluminum flat plate heat sink with a simulated electronic load. The PHP heat sink used water as the working fluid and had 20 parallel channels with dimensions 2 mm × 2 mm × 119 mm. Experiments were run under various operating conditions, and thermal resistance of the PHP was calculated. The performance enhancement provided by the PHP was assessed by comparing the thermal resistance of the heat sink with no working fluid to that of it charged with water. Uncharged, the PHP was found to have a resistance of 1.97 K/W. Charged to a fill ratio of approximately 75% and oriented vertically, the PHP achieved a resistance of .49 K/W and .53 K/W when the condenser temperature was set to 20°C and 30°C, respectively. When the PHP was tilted to 45° above horizontal the PHP had a resistance of .76 K/W and .59 K/W when the condenser was set 20°C and 30°C, respectively. The PHP greatly improves the heat transfer properties of the heat sink compared to the aluminum plate alone. Additional considerations regarding flat plate PHP design are also presented.


2014 ◽  
Vol 1082 ◽  
pp. 309-314 ◽  
Author(s):  
Diogo L.F. Santos ◽  
Larissa S. Marquardt ◽  
Paulo H.D. Santos ◽  
Thiago Antonini Alves

This work presents a theoretical and experimental analysis of a heat exchanger assisted by five heat pipes made of copper with a metallic mesh 100 of stainless steel which was used as capillary structure. All heat pipes used water as the working fluid and were designed based on the capillary limit model. The heat pipes were developed and tested under heat loads varying from 20 to 50 W before application into the heat exchanger. The theoretical and experimental results were compared and all heat pipes worked satisfactorily. Thereafter, it is presented the development of heat pipe heat exchanger which was tested under heat loads varying from 100 to 250 W. The highest temperature measured on the external surface of the heat pipes was 90 oC and the heat exchanger thermal efficiency varied from 74 to 80%. It is showed that the use of a stainless steel mesh as a porous wick was proved to work successfully in heat pipes.


2018 ◽  
Vol 207 ◽  
pp. 04004
Author(s):  
Radovan Nosek ◽  
Tatiana Liptáková ◽  
Libor Trško ◽  
Zuzana Kolková ◽  
Milan Malcho ◽  
...  

You Heat pipe is a high efficiency heat transfer element, depends on the evaporation, condensation and circulation of inside working fluid. The working fluid of a high temperature pulsating heat pipe is generally alkali metals, and sodium heat pipe can operate in range of 500-1100°C. In order to investigate terminal velocity of working fluid, the glass pulsating heat pipe was produced for experimental purposes. The experiment was carried out, in order to simulate real operating conditions in range of 500-1100°C. Sudden boiling of liquid sodium (b.p. = 883°C at 1 atm) inside the all quartz-made heat pipe results in high-temperature reaction of sodium vapour with the inner wall surface. The reaction became more aggressive with increasing vapour temperature and resulted in heat pipe explosion. The evaluation of damage character is analysed in this paper.


Sign in / Sign up

Export Citation Format

Share Document