Current-Fed Flyback Push-Pull DC-DC Converter Based on Three-Phase Transformer

2014 ◽  
Vol 614 ◽  
pp. 164-167
Author(s):  
You Chen Yuan ◽  
Yang Zhang ◽  
Yu Wei Chen

Three-phase current-fed flyback push-pull dc-dc converter is proposed in this paper, which is a new circuit topology putting into practice based on current-fed flyback push-pull dc-dc converter. Structure is simplified; cost is cut down; efficiency and reliability are improved all by the high frequency three-phase transformer technique that carries out functions of flyback transformer as well as push-pull transformer at the same time. Three-phase transformer can be separated into relatively independent functions of flyback transformer and push-pull transformer with the reluctance produced by the magnetic gap in the central phase; the flyback transformer produces only common-mode flux in the magnetic circuit of push-pull transformer and does not influence its output signal; the magnetic flux in push-pull transformer is blocked by the magnetic gap and can only flow through the outer magnetic loop. Investigational device is designed; static and dynamic characteristics are observed and test results are verified by the experimentation.

2014 ◽  
Vol 670-671 ◽  
pp. 1008-1011 ◽  
Author(s):  
Li Ping Li

The experiments of static and dynamic characteristics of rubber bushing for rear suspension telescopic shock absorber were carried out at four directions such as axial, radial, torsion and yaw, by MTS831 and SAGINOMIYA test system. The tests prove that: rubber bushing has great damping, and rubber bushing has obvious nonlinear characteristic; the dynamic stiffness under low frequency and large amplitude excitation is smaller, while the dynamic stiffness under high frequency and small amplitude excitation is greater; at the same amplitude, the dynamic stiffness increases with the increasing excitation frequency. The test results can provide support for the optimization design of rubber bushing.


1980 ◽  
Vol 17 (4) ◽  
pp. 301-307
Author(s):  
Arifur Rahman

This paper describes a simple laboratory test equipment for classroom determination of the normal magnetization curve and hysteresis loop of a built-in ferromagnetic core. The circuit details, steps of design of the magnetic circuit coils and test results are also presented.


1968 ◽  
Vol 11 (1) ◽  
pp. 204-218 ◽  
Author(s):  
Elizabeth Dodds ◽  
Earl Harford

Persons with a high frequency hearing loss are difficult cases for whom to find suitable amplification. We have experienced some success with this problem in our Hearing Clinics using a specially designed earmold with a hearing aid. Thirty-five cases with high frequency hearing losses were selected from our clinical files for analysis of test results using standard, vented, and open earpieces. A statistical analysis of test results revealed that PB scores in sound field, using an average conversational intensity level (70 dB SPL), were enhanced when utilizing any one of the three earmolds. This result was due undoubtedly to increased sensitivity provided by the hearing aid. Only the open earmold used with a CROS hearing aid resulted in a significant improvement in discrimination when compared with the group’s unaided PB score under earphones or when comparing inter-earmold scores. These findings suggest that the inclusion of the open earmold with a CROS aid in the audiologist’s armamentarium should increase his flexibility in selecting hearing aids for persons with a high frequency hearing loss.


2020 ◽  
Vol 64 (1-4) ◽  
pp. 969-975
Author(s):  
Hiroaki Kikuchi ◽  
Yuki Sato

We investigated effects of contact gap on magnetic nondestructive evaluation technique using a magnetic single-yoke probe. Firstly, we evaluated hysteresis curves and impedance related to permeability of the material measured by a single-yoke probe, when an air gap length between the probe and specimens changes. The hysteresis curve gradually inclines to the axis of the magneto-motive force and magneto-motive force at which the magnetic flux is 0 decreases with increasing the gap length. The effective permeability also decreases with increasing the gap thickness. The incremental of gap thickness increases the reluctance inside the magnetic circuit composed of the yoke, specimen and gap, which results in the reduction of flux applying to specimen.


2019 ◽  
Vol 139 (3) ◽  
pp. 339-347 ◽  
Author(s):  
Shotaro Takahashi ◽  
Satoshi Ogasawara ◽  
Masatsugu Takemoto ◽  
Koji Orikawa ◽  
Michio Tamate

2006 ◽  
Vol 14 (2) ◽  
pp. 489-493
Author(s):  
Michael J. Gefell ◽  
Erin C. Rankin ◽  
William R. Jones

Author(s):  
C. Vidhya ◽  
V. Ravikumar ◽  
S. Muralidha

: The objective of this paper is to implement an ac link universal power converter controlled BLDC motor for medical applications. The ac link universal power converter is a soft switched high frequency ac link converter, created using the parallel combination of an inductor and a capacitor. The parallel ac link converter handle the ac voltages and currents with low reactive ratings at the link and offers improved power factor, low power consumption, more efficiency and less weight on comparison with the traditional dc link converter. Because of the high throughput, BLDC motors are preferred widely medical applications. A modulation technique called Space Vector Pulse Width Modulation (SVPWM) is used to generate the three phase power for the BLDC motors from the input DC supply. To validate the proposed system, simulations are performed in MATLAB – Simulink and an experimental prototype is constructed to supplement the simulation results.


Sign in / Sign up

Export Citation Format

Share Document