Study on Granulation of Anaerobic Sludge in UASB Reactor Adding Cationic Polymer Treating Low Strength Wastewater at Room Temperature

2011 ◽  
Vol 71-78 ◽  
pp. 2974-2977 ◽  
Author(s):  
Zong Lian She ◽  
Jian Wu ◽  
Xiao Hui Fu ◽  
En Shi ◽  
Bao Shi Li ◽  
...  

Effect of cationic polymer on granulation and COD removal efficiency in lab scale UASB reactors was examined, treating low-strength wastewater (COD 300-500mg l-1) at room temperature. It was shown that cationic polymer was more effective for enhancing sludge granulation and COD removal efficiency as compared to the control experiment (without additives). After day 166 of operation, the amount of granules size above 0.5mm accounted for 32.1% of total sludge, higher than that of control experiment (19.3%). At 1.03 kg COD m-3 d-1 of OLR and 9.8 h of HRT, the effluent VFA had a maximum value of 168mg l-1 and 240mg l-1 in Reactor A and B respectively. The polymer-amended reactor took 36days to receive 1.44 kg COD m-3 d-1 of OLR at the 7.8 h of HRT, shorter than the control reactor (54days). The two reactors obtained above 80% in COD removal efficiency. It is shown that UASB reactor can also achieve higher COD removal treating low strength wastewater at room temperature.

1991 ◽  
Vol 24 (3-4) ◽  
pp. 149-160 ◽  
Author(s):  
J. Rintala ◽  
J. L. Sanz Martin ◽  
G. Lettinga

Anaerobic treatment of sulfate - rich (COD/SO4 ratio 1.4-2.1) clarified Whitewater from a thermomechanical pulping (TMP) process was studied in three laboratory-scale upflow anaerobic sludge blanket (UASB) reactors at 55°C and in batch digesters at 55° and 65°C. Different seed materials were used in the UASB reactors. The highest COD removal efficiency (effluent sulfide stripped) achieved was approximately 65 % in the UASB reactors. About 55 % COD removal efficiency was obtained at a loading rate of about 41 kgCODm−3d−1 in the UASB reactor seeded with thermophilic sludge cultivated with volatile fatty acids (VFAs). The total sulfide present in the liquid phase after anaerobic treatment accounted for approximately 65-78 % and 15-61 % of the removed COD in the batch digesters and the UASB reactors, respectively. Sulfate reduction was almost complete in the batch digesters, whereas about 24-64 % of sulfate was reduced in the UASB reactors. Acetate utilization for sulfate reduction was apparent in the batch digesters, whereas that could not be demonstrated in the UASB reactors. Sulfate reduction in the UASB reactors was obviously substrate limited. In conclusion, thermophilic anaerobic treatment is an alternative for the treatment of warm sulfate rich TMP process water.


2008 ◽  
Vol 57 (7) ◽  
pp. 1047-1052 ◽  
Author(s):  
U. Durán ◽  
O. Monroy ◽  
J. Gómez ◽  
F. Ramírez

The biological elimination of polymeric resins compounds (PRC) such as acrylic acid and their esters, vinyl acetate and styrene under methanogenic and oxygen-limited methanogenesis conditions was evaluated. Two UASB reactors (A and B) were used and the removal of the organic matter was studied in four stages. Reactor A was used as methanogenic control during the study. Initially both reactors were operated under methanogenic conditions. From the second stage reactor B was fed with 0.6 and 1 mg/L·d of oxygen (O2). Reactor A had diminution in chemical oxygen demand (COD) removal efficiency from 75±4% to 37±5%, by the increase of PRC loading rate from 750 to 1125 mg COD/L·d. In this reactor there was no styrene elimination. In reactor B the COD removal efficiency was between 73±5% and 80±2%, even with the addition of O2 and increase of the PRC loading rate, owing to oxygen being used in the partial oxidation of these compounds. In this reactor the yields were modified from 0.56 to 0.40 for CH4 and from 0.31 to 0.60 for CO2. The O2 in low concentrations increased 40.7% the consumption rates of acrylic acid, methyl acrylate and vinyl acetate, allowing styrene consumption with a rate of 0.103 g/L·d. Batch cultures demonstrated that under methanogenic and oxygen-limited methanogenesis conditions, the glucose was not used as an electron acceptor in the elimination of PRC.


2018 ◽  
Vol 141 (4) ◽  
Author(s):  
Tao Wang ◽  
Zhenxing Huang ◽  
Hongyan Ren ◽  
Hengfeng Miao ◽  
Minxing Zhao ◽  
...  

This study aimed to investigate the effectiveness of the full-scale internal circulation (IC) reactor in biodegrading of municipal solid waste (MSW) fresh leachate under mesophilic conditions, where the anaerobic process stability, biogas yield, and sludge granulation were intensively investigated. The effects of operational parameters on the influent organic loading rate (OLR), chemical oxygen demand (COD) removal efficiency, alkalinity (ALK), pH, volatile fatty acids (VFAs) accumulation, and effluent recirculation were also studied. The results showed that the reactor operated stably and effectively. The COD removal efficiency and biogas yield could be maintained at (92.8 ± 2.0)% and (0.47 ± 0.05) m3/kg CODremoval, respectively, with the influent OLR (24.5 ± 0.9) kg COD/(m3 d) and hydraulic retention time (HRT) 2.7d during the stable operation phase. Meanwhile, this study demonstrated that 1.5–3.0 m/h would be the optimal Vup for the reactor, corresponding to the effluent recirculation of 32.5–78.0 m3/h. Moreover, it was found that the content of extracellular polymeric substances (EPS) in the anaerobic sludge increased from 50.3 to 140.7 mg/g volatile suspended solids (VSS), and the sludge had good granular performance during the reactor operation.


2013 ◽  
Vol 726-731 ◽  
pp. 2813-2817
Author(s):  
Guang Li ◽  
Jing Li ◽  
Ke Sun

The interior diversion expanded granular sludge bed was concurrently operated for 140d to study the characteristic of the granular sludge bed. The influent COD concentration varied from 2000mg/L to 22300 mg/L, hydraulic retention time was maintained constant at 24 h and the organic loading rate was changed through a change in substrate concentration. The results showed that the reactor had great COD removal efficiency. When the MLSS was 23.1g/L, the influent COD was 18890mg/L, the COD removal efficiency was 80.4%; The interior diversion EGSB could greatly improve the role of gas-dynamic, when the liquid upflow velocity was 3.55m/h, the gas production was 5.96 L/d shows higher sludge bed expansion rate than 2.77 L/d about 9.5%. During the experimental, the anaerobic sludge has the following properties: the average sludge diameter was increased from 0.41mm to 1.66mm. Observed under the scanning electronic microscopy, we found that the sludge appeared obviously granulation, the bacteria amount and species are more than seed sludge after operation of 50d. It was found that rough surface of anaerobic sludge has clear figure with being covered by mucous lamina, with visible hole or cavity on surface.


2002 ◽  
Vol 45 (10) ◽  
pp. 243-248 ◽  
Author(s):  
L. Seghezzo ◽  
R.G. Guerra ◽  
S.M. González ◽  
A.P. Trupiano ◽  
M.E. Figueroa ◽  
...  

The performance of a sewage treatment system consisting of a settler followed by an Upflow Anaerobic Sludge Bed (UASB) reactor is described. Mean ambient and sewage temperature were 16.5 and 21.6°C, respectively. Total Chemical Oxygen Demand (CODt) concentration averaged 224.2 and 152.6 mg/L, for raw and settled sewage, respectively. The effluent concentration was 68.5 mgCODt/L. Total and suspended COD removal efficiencies of approximately 70 and 80%, respectively, have been observed in the system at a mean Hydraulic Retention Time (HRT) of 2 + 5 h. Maximum COD removal efficiency was achieved in the UASB reactor when upflow velocity (Vup) was 0.43 m/h (HRT = 6 h). Mean Specific Methanogenic Activity (SMA) and Volatile Suspended Solids (VSS) concentration in the granular sludge bed were 0.11 gCOD-CH4/gVSS.d and 30.0 gVSS/Lsludge, respectively. SMA was inversely related to VSS concentration, and both parameters varied along the sludge bed height. The Solids Retention Time (SRT) in the reactor was 450 days. Sludge characteristics have not been affected by changes of up to one month in Vup in the range 0.28–0.85 m/h (HRT 3–9 h). This system or two UASB reactors in series could be an alternative for sewage treatment under moderate temperature conditions.


1995 ◽  
Vol 32 (12) ◽  
pp. 121-129 ◽  
Author(s):  
A. Espinosa ◽  
L. Rosas ◽  
K. Ilangovan ◽  
A. Noyola

A laboratory UASB reactor was fed with cane molasses stillage at organic loadings from 5 to 21.5 kg COD/m3 d. With an organic load of 17.4 kg COD/m3 d, an accumulation of VFA, principally propionic acid, was observed due to little bioavailability or lack of trace metals (Fe, Ni, Co and Mo). Associated to this, the performance of the UASB reactor was low (44% COD removal efficiency), with an alkalinity ratio above 0.4. The addition of Fe (100 mg/l), Ni (15 mg/l), Co (10 mg/l) and Mo (0.2 mg/l) to the influent reduced significantly the level of propionic acid (5291mg/l to 251 mg/l) and acetic acid (1100 mg/l to 158 mg/l). The COD removal efficiency increased from 44% to 58%, the biogas production from 10.7 to 14.8 l/d (NTP) and 0.085 to 0.32 g CH4-COD/g SSV d for specific sludge methanogenic activity with propionic acid as substrate. These improved results were obtained with high COD (68.9 g/l) and organic load (21.5 kg COD/m3 d).


2001 ◽  
Vol 44 (4) ◽  
pp. 167-174 ◽  
Author(s):  
R. M.L. Bolaños ◽  
M. B.A. Varesche ◽  
M. Zaiat ◽  
E. Foresti

A bench-scale horizontal-flow anaerobic immobilized biomass (HAIB) reactor was assayed aiming to verify its potential use for phenol degradation. The HAIB reactor consisted of a bore-silicate tube (100 cm long; 5.04 cm diameter) filled with polyurethane foam matrices containing immobilized anaerobic sludge. Before being subjected to phenol, the reactor was fed with synthetic substrate at the influent chemical oxygen demand (COD) of 1,028 mg.l−1 achieving 98% of COD removal efficiency. Thereafter, phenol as the sole carbon source was added under step-increasing concentrations from 50 to 1,200 mg.l−1. Phenol degradation was evaluated by gas chromatographic analysis of influent and effluent samples. Process monitoring included determinations of pH, volatile acids, alkalinity and COD. The HAIB reactor was operated at a constant hydraulic detention time (HDT) of 12 hours. After 33 days with 50 mg/l of phenol in the influent, the reactor achieved 98% of COD removal efficiency. Successful phenol degradation (efficiency removal of 99%) occurred for influent concentrations of 100, 300, 600, 900 and 1,200 mg.l−1 after 148, 58, 47, 29 and 7 days, respectively. The predominance of Methanosaeta-like, rods and methanogenic cocci could be observed in all the operating conditions, besides the presence of phenol oxidizing microorganisms as irregular rods. The results indicate that phenol degradation at very high rates can be accomplished in HAIB reactors containing acclimatized biomass.


2008 ◽  
Vol 58 (2) ◽  
pp. 373-377
Author(s):  
Soosan J. Panicker ◽  
M. C. Philipose ◽  
Ajit Haridas

The Buoyant Filter Bio-Reactor (BFBR) is a novel and very efficient method for the treatment of complex wastewater. Sewage is a complex wastewater containing insoluble COD contributed by fat and proteins. The fat and proteins present in the domestic sewage cause operational problems and underperformance in the Upflow Anaerobic Sludge Blanket Reactor, used now for treating sewage anaerobically. The biogas yield from the BFBR is 0.36 m3/kg COD reduced and the methane content was about 70–80%. Production of methane by anaerobic digestion of organic waste had the benefit of lower energy costs for treatment and is thus environmentally beneficial to the society by providing a clean fuel from renewable feed stocks. The BFBR achieved a COD removal efficiency of 80–90% for an organic loading rate of 4.5 kg/m3/d at a hydraulic retention time of 3.25 hours. The effluent COD was less than 100 mg/l, thus saving on secondary treatment cost. No pretreatment like sedimentation was required for the influent to the BFBR. The BFBR can produce low turbidity effluent as in the activated sludge process (ASP). The land area required for the BFBR treatment plant is less when compared to ASP plant. Hence the problem of scarcity of land for the treatment plant is reduced. The total expenditure for erecting the unit was less than 50% as that of conventional ASP for the same COD removal efficiency including land cost.


2005 ◽  
Vol 52 (1-2) ◽  
pp. 299-305 ◽  
Author(s):  
R.C. Leitão ◽  
J.A. Silva-Filho ◽  
W. Sanders ◽  
A.C. van Haandel ◽  
G. Zeeman ◽  
...  

In this investigation, the performance of Upflow Anaerobic Sludge Blanket (UASB) reactors treating municipal wastewater was evaluated on the basis of: (i) COD removal efficiency, (ii) effluent variability, and (iii) pH stability. The experiments were performed using 8 pilot-scale UASB reactors (120 L) from which some of them were operated with different influent COD (CODInf ranging from 92 to 816 mg/L) and some at different hydraulic retention time (HRT ranging from 1 to 6 h). The results show that decreasing the CODInf, or lowering the HRT, leads to decreased efficiencies and increased effluent variability. During this experiment, the reactors could treat efficiently sewage with concentration as low as 200 mg COD/L. They could also be operated satisfactorily at an HRT as low as 2 hours, without problems of operational stability. The maximum COD removal efficiency can be achieved at CODInf exceeding 300 mg/L and HRT of 6 h.


2010 ◽  
Vol 160-162 ◽  
pp. 1440-1444
Author(s):  
Dou Li ◽  
Dong Wei Li

The cyclohexanone production wastewater includes hazardous material such as cyclohexanone and cyclohexane which can harm the vessel of human body resulting in coagulation necrosis of viscera and brain. Our experiment choosed the cyclohexanone production wastewater to be investigated, and used the self-made anaerobic upflow bed filter (UBF) to deal with it. We try to find the optimal operational parameters which can make the degradation of hazardous materials maximizing. The COD removal efficiency was decreasing with the COD of influent’s increasing in starting stage, the shock load made the microbe in UBF can’t adapt the high VLR temporarily. In the running stage, the anaerobic sludge in UBF was incompact and the settleability of sludge was not very well. As the UBF running, the granular sludge shaped up greatly, the COD removal efficiency kept on 80%. The result showed that the UBF reactor was valid for hazardous material in cyclohexanone production wastewater.