Enhanced COD Removal Efficiency by Using an Electro-Shocking Biofilm

2014 ◽  
Vol 1073-1076 ◽  
pp. 693-695
Author(s):  
Zhen Wei Ni ◽  
Yin Mei Wang ◽  
Wen Ping Cao

Two parallel biofilm reactors were developed and applied for treating the simulated wastewater. The experimental results showed that compared with a without electric-shocking biofilm, and a mean removal rate of COD increased by 18.82% by shocking of direct current. Which suggested that the electro-shocking can significantly increase the removal rate of COD.

2016 ◽  
Vol 74 (7) ◽  
pp. 1509-1517 ◽  
Author(s):  
Linan Zhu ◽  
Hailing He ◽  
Chunli Wang

The hybrid membrane bioreactor (HMBR) has been applied in ship domestic sewage treatment under high volumetric loading for ship space saving. The mechanism and influence factors on the efficiency, including hydraulic retention time (HRT), dissolved oxygen (DO) of chemical oxygen demand (COD) removal were investigated. The HMBR's average COD removal rate was up to 95.13% on volumetric loading of 2.4 kgCOD/(m3•d) and the COD concentration in the effluent was 48.5 mg/L, far below the International Maritime Organization (IMO) discharge standard of 125 mg/L. DO had a more remarkable effect on the COD removal efficiency than HRT. In addition, HMBR revealed an excellent capability of resisting organics loading impact. Within the range of volumetric loading of 0.72 to 4.8 kg COD/(m3•d), the effluent COD concentration satisfied the discharge requirement of IMO. It was found that the organics degradation in the aeration tank followed the first-order reaction, with obtained kinetic parameters of vmax (2.79 d−1) and Ks (395 mg/L). The original finding of this study had shown the effectiveness of HMBR in organic contaminant degradation at high substrate concentration, which can be used as guidance in the full scale of the design, operation and maintenance of ship domestic sewage treatment devices.


2012 ◽  
Vol 610-613 ◽  
pp. 1691-1695
Author(s):  
Chun Juan Dong ◽  
Qing Ye Pan

Treatment of actual domestic wastewater at ambient temperature, even low temperature is considered to be difficult by traditional systems. The present study is related to treatment of actual domestic wastewater in an EGSB reactor. The study showed the effectiveness of biological treatment of actual domestic wastewater involving appropriate microorganism and granules in an EGSB reactor. At 26°C, the reactor was operated at 18.7kg COD.m−3.d−1 of average organic loading and 83% high COD removal efficiency, and even at the highest loading rate of 57.12kgCOD.m−3.d−1, the COD removal efficiency still could attain to 68%. Varied influent flow need to supply varied optimal and thus to ensure the optimal removal effect. Low temperature would cause pollutant removal rate decrease. However, enhancing could optimize the contact of sludge and wastewater and thus strengthen the performance effect. Modified Stover–Kincannon model was applied to data obtained from experimental studies in EGSB reactor. Treatment efficiencies of the reactor were investigated at different hydraulic retention times (0.5-1.3h) and different operation temperature (15°C, 26°C). The modified Stover–Kincannon model was best fitted to the EGSB reactor, and the substrate utilization rate( ), saturation constant value( ), and actual pollutant removal rate( ) were found to be , , and for 26°C, , , and for 15°C( before increasing ), and , , and for 15°C(after increasing ). Low temperature could cause decrease and thus cause distinct decreasing of COD removal efficiency. However, increasing could increase and accordingly increase COD removal efficiency.


2013 ◽  
Vol 295-298 ◽  
pp. 1307-1310
Author(s):  
Xi Tian ◽  
Ming Xin Huo ◽  
De Jun Bian ◽  
Sheng Shu Ai ◽  
Qing Kai Ren

The wastewater produced from the polytetrahydrofuran (PolyTHF) was treated with iron-carbon micro electrolysis process. This paper had studied the COD removal efficiency influences of primary PH value, reaction time, the quality ratio of the iron-carbon, the quality and volume ratio of Fe-wastewater. The results show that when pH value is 3, the quality ratio of the iron-carbon is 11 and the quality and volume ratio of Fe and wastewater is 17 with contact time of 90 min, the wastewater COD removal rate can reach as high as 95.0%.


2010 ◽  
Vol 61 (7) ◽  
pp. 1749-1756 ◽  
Author(s):  
B. Q. Liao ◽  
M. R. Zheng ◽  
L. Ratana-Rueangsri

A comparative study on the treatment of synthetic kraft evaporator condensate was conducted using thermophilic (55°C) and mesophilic (30°C) membrane aerated biofilm reactors (MABRs) and sequencing batch reactors (SBRs) for 8 months. Under tested conditions, a chemical oxygen demand (COD) removal efficiency of 80–95% was achieved with both thermophilic and mesophilic MABRs and SBRs. The COD removal efficiency of thermophilic MABR (80–90%) was slightly lower than that of the mesophilic MABR (85–95%) and the thermophilic SBR (90–95%). A significant amount (13–37%) of COD was stripped by conventional aeration in the SBRs, while stripping in MABRs was negligible. Simultaneous COD removal and denitrification were observed in the mesophilic MABR, while the thermophilic MABR contributed mainly for COD removal. Nitrification was not significant in both the thermophilic and mesophilic MABRs. The results suggest that treatment of kraft evaporator condensate is feasible with the use of both thermophilic and mesophilic MABRs in terms of COD removal with the advantages of negligible stripping.


2013 ◽  
Vol 777 ◽  
pp. 122-126
Author(s):  
Li Ping Wang ◽  
Xin Ying Li ◽  
Xiang Mei Li

Used Fenton reagent and fly ash combined process to treat dioctyl phthalate (DOP) simulated wastewater. Influences of pH, concentration of H2O2, Fe2+ concentration, fly ash dosage and other factors effect of COD were studied. The results showed that, under the synergies of the fly ash, Fenton reagent on the COD removal efficiency was better than Fenton reagent used alone. When the pH was 5, H2O2 concentration was 1.2 g/L, Fe2+ concentration was 1.0g/L, fly ash dosage was 4 g, and COD removal efficiency reached 83.21%.


2011 ◽  
Vol 183-185 ◽  
pp. 1400-1403
Author(s):  
Xue Zheng Meng ◽  
Xiang Sheng Cao ◽  
Jie Rui Li

The effects of molybdenum (Ⅵ) on the denitrification efficiency of activated sludge process were investigated with batch tests. The results indicated that up to 5 mg/L of Molybdenum (Ⅵ) concentrations in the liquor of activated sludge process could accelerate the nitrate removal rate, exhibiting maximum stimulation at 1 mg/L. Up to 4 mg/L of Molybdenum (Ⅵ) concentrations, the COD removal efficiency was enhanced. Up to 1mg/L of Molybdenum (Ⅵ) concentrations, the TTC-DHA was enhanced but higher concentration showed inhibitory effects. Based on the integrated effects of Molybdenum (Ⅵ) on nitrate and COD removal with the TTC-DHA change, 1mg/L of Molybdenum (Ⅵ) is proposed as the best concentration for denitrification of activated sludge.


2013 ◽  
Vol 726-731 ◽  
pp. 2300-2304
Author(s):  
Hai Shan Dong ◽  
Jing Jing Liu ◽  
Peng Yan ◽  
Rong Yang

This topic used the method of demulsification-Fenton oxidation to deal with the waste emulsion, and analyzed the influencing factors of COD removal efficiency . Experimental results show that when the dosage of demulsifier is 10g/L ,optimum aeration for 1h , dosage of Fe2+ is 500mg/L, the dosage of hydrogen peroxide is 50ml/L, After Fenton reagent has oxided for 1.5 h, the COD removal rate can up to 93.4%.


2019 ◽  
Vol 2019 ◽  
pp. 1-9
Author(s):  
Quang-Minh Nguyen ◽  
Duy-Cam Bui ◽  
Thao Phuong ◽  
Van-Huong Doan ◽  
Thi-Nham Nguyen ◽  
...  

The effect of copper, zinc, chromium, and lead on the anaerobic co-digestion of waste activated sludge and septic tank sludge in Hanoi was studied in the fermentation tests by investigating the substrate degradation, biogas production, and process stability at the mesophilic fermentation. The tested heavy metals were in a range of concentrations between 19 and 80 ppm. After the anaerobic tests, the TS, VS, and COD removal efficiency was 4.12%, 9.01%, and 23.78% for the Cu(II) added sample. Similarly, the efficiencies of the Zn(II) sample were 1.71%, 13.87%, and 16.1% and Cr(VI) efficiencies were 15.28%, 6.6%, and 18.65%, while the TS, VS, and COD removal efficiency of the Pb(II) added sample was recorded at 16.1%, 17.66%, and 16.03% at the concentration of 80 ppm, respectively. Therefore, the biogas yield also decreased by 36.33%, 31.64%, 31.64%, and 30.60% for Cu(II), Zn(II), Cr(VI), and Pb(II) at the concentration of 80 ppm, compared to the raw sample, respectively. These results indicated that Cu(II) had more inhibiting effect on the anaerobic digestion of the sludge mixture than Zn(II), Cr(VI), and Pb(II). The relative toxicity of these heavy metals to the co-digestion process was as follows: Cu (the most toxic) > Zn > Cr > Pb (the least toxic). The anaerobic co-digestion process was inhibited at high heavy metal concentration, which resulted in decreased removal of organic substances and produced biogas.


2017 ◽  
Vol 77 (3) ◽  
pp. 565-575 ◽  
Author(s):  
Zhenchao Zhang

Abstract Hydroxypropyl guar gum is considered to be a main component of oilfield fracturing wastewater (OFW). This work is intended to optimize the experimental conditions for the maximum oxidative degradation of hydroxypropyl guar gum by the coagulation and UV/H2O2/ferrioxalate complexes process. Optimal reaction conditions were proposed based on the chemical oxygen demand (COD) removal efficiency and UV_vis spectra analysis. The overall removal efficiency of COD reached 83.8% for a dilution ratio of raw wastewater of 1:2, pH of 4 and FeCl3 loading of 1,000 mg/L in the coagulation process; the dosage of H2O2 (30%,v/v) was 0.6% (v/v) and added in three steps, the n(H2O2)/n(Fe2+) was 2:1, n(Fe2+)/n(C2O42−) was 3:1 and pH was 4 in the UV/H2O2/ferrioxalate complexes process; pH was adjusted to 8.5–9 by NaOH and then cationic polyacrylamide (CPAM) of 2 mg/L was added in the neutralization and flocculation process. The decrease in COD during the coagulation process reduced the required H2O2 dosage and improved efficiency in the subsequent UV/H2O2/ferrioxalate complexes process. Furthermore, COD removal efficiency significantly increased by more than 13.4% with the introduction of oxalate compared with UV/Fenton. The UV_vis spectra analysis results indicated that the coagulation and UV/H2O2/ferrioxalate complexes process could efficiently remove the hydroxypropyl guar gum dissolved in OFW. An optimal combination of these parameters produced treated wastewater that met the GB8978-1996 Integrated Wastewater Discharge Standard level III emission standard.


2012 ◽  
Vol 441 ◽  
pp. 589-592
Author(s):  
Zhi Min Fu ◽  
Yu Gao Zhang ◽  
Xiao Jun Wang

A combined process of biological wriggle bed and ozone biological aerated filter was utilized to treat textile wastewater. Results showed that COD removal efficiency was almost 90.4%. The average effluent COD was 85.87 mg/L. The effluent colority was 64-32 times. This study indicated that the combined process is potentially useful for treating textile wastewater.


Sign in / Sign up

Export Citation Format

Share Document