Treatment of synthetic kraft evaporator condensate using thermophilic and mesophilic membrane aerated biofilm reactors

2010 ◽  
Vol 61 (7) ◽  
pp. 1749-1756 ◽  
Author(s):  
B. Q. Liao ◽  
M. R. Zheng ◽  
L. Ratana-Rueangsri

A comparative study on the treatment of synthetic kraft evaporator condensate was conducted using thermophilic (55°C) and mesophilic (30°C) membrane aerated biofilm reactors (MABRs) and sequencing batch reactors (SBRs) for 8 months. Under tested conditions, a chemical oxygen demand (COD) removal efficiency of 80–95% was achieved with both thermophilic and mesophilic MABRs and SBRs. The COD removal efficiency of thermophilic MABR (80–90%) was slightly lower than that of the mesophilic MABR (85–95%) and the thermophilic SBR (90–95%). A significant amount (13–37%) of COD was stripped by conventional aeration in the SBRs, while stripping in MABRs was negligible. Simultaneous COD removal and denitrification were observed in the mesophilic MABR, while the thermophilic MABR contributed mainly for COD removal. Nitrification was not significant in both the thermophilic and mesophilic MABRs. The results suggest that treatment of kraft evaporator condensate is feasible with the use of both thermophilic and mesophilic MABRs in terms of COD removal with the advantages of negligible stripping.

2016 ◽  
Vol 74 (7) ◽  
pp. 1509-1517 ◽  
Author(s):  
Linan Zhu ◽  
Hailing He ◽  
Chunli Wang

The hybrid membrane bioreactor (HMBR) has been applied in ship domestic sewage treatment under high volumetric loading for ship space saving. The mechanism and influence factors on the efficiency, including hydraulic retention time (HRT), dissolved oxygen (DO) of chemical oxygen demand (COD) removal were investigated. The HMBR's average COD removal rate was up to 95.13% on volumetric loading of 2.4 kgCOD/(m3•d) and the COD concentration in the effluent was 48.5 mg/L, far below the International Maritime Organization (IMO) discharge standard of 125 mg/L. DO had a more remarkable effect on the COD removal efficiency than HRT. In addition, HMBR revealed an excellent capability of resisting organics loading impact. Within the range of volumetric loading of 0.72 to 4.8 kg COD/(m3•d), the effluent COD concentration satisfied the discharge requirement of IMO. It was found that the organics degradation in the aeration tank followed the first-order reaction, with obtained kinetic parameters of vmax (2.79 d−1) and Ks (395 mg/L). The original finding of this study had shown the effectiveness of HMBR in organic contaminant degradation at high substrate concentration, which can be used as guidance in the full scale of the design, operation and maintenance of ship domestic sewage treatment devices.


2008 ◽  
Vol 57 (7) ◽  
pp. 1047-1052 ◽  
Author(s):  
U. Durán ◽  
O. Monroy ◽  
J. Gómez ◽  
F. Ramírez

The biological elimination of polymeric resins compounds (PRC) such as acrylic acid and their esters, vinyl acetate and styrene under methanogenic and oxygen-limited methanogenesis conditions was evaluated. Two UASB reactors (A and B) were used and the removal of the organic matter was studied in four stages. Reactor A was used as methanogenic control during the study. Initially both reactors were operated under methanogenic conditions. From the second stage reactor B was fed with 0.6 and 1 mg/L·d of oxygen (O2). Reactor A had diminution in chemical oxygen demand (COD) removal efficiency from 75±4% to 37±5%, by the increase of PRC loading rate from 750 to 1125 mg COD/L·d. In this reactor there was no styrene elimination. In reactor B the COD removal efficiency was between 73±5% and 80±2%, even with the addition of O2 and increase of the PRC loading rate, owing to oxygen being used in the partial oxidation of these compounds. In this reactor the yields were modified from 0.56 to 0.40 for CH4 and from 0.31 to 0.60 for CO2. The O2 in low concentrations increased 40.7% the consumption rates of acrylic acid, methyl acrylate and vinyl acetate, allowing styrene consumption with a rate of 0.103 g/L·d. Batch cultures demonstrated that under methanogenic and oxygen-limited methanogenesis conditions, the glucose was not used as an electron acceptor in the elimination of PRC.


Processes ◽  
2019 ◽  
Vol 7 (7) ◽  
pp. 418 ◽  
Author(s):  
Pedro Cisterna-Osorio ◽  
Verónica Lazcano-Castro ◽  
Gisela Silva-Vasquez ◽  
Mauricio Llanos-Baeza ◽  
Ignacio Fuentes-Ortega

The objective of this work is to evaluate the impact of innovative modifications made to conventional effluent capture and discharge devices used in subsurface flow wetlands (SSFW). The main modifications that have been developed extend the influence of the capture and discharge device in such a way that the SSFW width and height are fully covered. This improved innovative device was applied and evaluated in two subsurface flow wetlands, one on a pilot scale and one on a real scale. To evaluate the impact of the innovative device with respect to the conventional one in the operational functioning of subsurface flow wetlands, the elimination of chemical oxygen demand (COD) was measured and compared. The results show that for the innovative device, the COD removal was 10% higher than for the conventional device, confirming the validity and effectiveness of the modifications implemented in the effluent capture and discharge devices used in SSFW.


2010 ◽  
Vol 37 (3) ◽  
pp. 496-501 ◽  
Author(s):  
K.N. Njau ◽  
M. Renalda

A horizontal subsurface flow constructed wetland (HSSFCW) was employed to remove tannins from the effluent of a tannins extracting company. Two HSSFCW cells with hydraulic retention time (HRT) of 9 d and packed with limestone were used. One cell without macrophytes was used as a control, while the second cell was planted with Phragmites mauritianus . Results indicated that HSSFCW was capable of treating tannin wastewater that has been seeded with primary facultative pond sludge. Tannins and chemical oxygen demand (COD) removal efficiency of 95.9% and 90.6% with outlet concentration of 27 mg/L and 86 mg/L, respectively, were obtained in the planted cell; while the tannins and COD removal efficiency of 91.1% and 89.5% with outlet concentration of 57 mg/L and 96 mg/L, respectively, were obtained in the control cell.


2021 ◽  
Vol 18 (4) ◽  
pp. 135-140
Author(s):  
Sanju Sreedharan

Zero energy technologies and sustainable energy production are the two major concerns of present day researches. Microbial fuel cells (MFCs) are bioreactors that extract chemical energy stored in organic compounds, into electric potential, through bio-degradation. The core reason for the high strength of effluent generated from slaughterhouses is animal blood. The current study evaluates the potential of MFC technology to reduce the pollution strength of cattle blood in terms of chemical oxygen demand (COD). The current study was piloted in three stages using lab scale two chambered MFC: The first stage was to determine the best oxidising agent as compared to natural aeration from three accessible options, KMnO4, diffused aeration and tape grass aquatic plant. KMnO4 was found to be the superlative with a 30% reduction in COD in 100 hrs batch reactor and a maximum power of 0.97 mW using 125 mL livestock blood. The second stage of the study optimised the concentration of KMnO4. At 500 mg/L KMnO4 concentration, 50% COD removal efficiency was acquired in a batch reactor of 60 hrs with an average energy output of 1.3 mW. In the final stage on the addition of coconut shell activated carbon with an Anolyte at a rate of 40 mL/125 mL of substrate COD removal efficiency increased to 74.9%.


2001 ◽  
Vol 44 (4) ◽  
pp. 167-174 ◽  
Author(s):  
R. M.L. Bolaños ◽  
M. B.A. Varesche ◽  
M. Zaiat ◽  
E. Foresti

A bench-scale horizontal-flow anaerobic immobilized biomass (HAIB) reactor was assayed aiming to verify its potential use for phenol degradation. The HAIB reactor consisted of a bore-silicate tube (100 cm long; 5.04 cm diameter) filled with polyurethane foam matrices containing immobilized anaerobic sludge. Before being subjected to phenol, the reactor was fed with synthetic substrate at the influent chemical oxygen demand (COD) of 1,028 mg.l−1 achieving 98% of COD removal efficiency. Thereafter, phenol as the sole carbon source was added under step-increasing concentrations from 50 to 1,200 mg.l−1. Phenol degradation was evaluated by gas chromatographic analysis of influent and effluent samples. Process monitoring included determinations of pH, volatile acids, alkalinity and COD. The HAIB reactor was operated at a constant hydraulic detention time (HDT) of 12 hours. After 33 days with 50 mg/l of phenol in the influent, the reactor achieved 98% of COD removal efficiency. Successful phenol degradation (efficiency removal of 99%) occurred for influent concentrations of 100, 300, 600, 900 and 1,200 mg.l−1 after 148, 58, 47, 29 and 7 days, respectively. The predominance of Methanosaeta-like, rods and methanogenic cocci could be observed in all the operating conditions, besides the presence of phenol oxidizing microorganisms as irregular rods. The results indicate that phenol degradation at very high rates can be accomplished in HAIB reactors containing acclimatized biomass.


2013 ◽  
Vol 67 (11) ◽  
pp. 2549-2559 ◽  
Author(s):  
S. Wang ◽  
J. Hovland ◽  
R. Bakke

The anaerobic biodegradation of reclaimer MEA (monoethanolamine) waste (MEAw) with easily degradable co-substrates was investigated in a laboratory-scale bioreactor at room temperature during a 160 d experimental run. The reactor that was constructed with three phases to facilitate attached biofilm and suspended biomass retention for degradation of the complex and challenging MEAw performed well. A feed strategy of step-wise increasing organic loading rate (OLR) by either increasing feed MEAw concentration or the hydraulic loading rate was applied. The system performance was evaluated by chemical oxygen demand (COD) removal efficiency, methane yield, MEA removal, and the accumulation of ammonia and volatile fatty acid (VFA). The total COD removal efficiency initially was 93% when the feed was mainly easily degradable co-substrate. The total removal dropped to 75% at the end when MEAw constituted 60% of the feed COD. Ion chromatography results show that the MEA and some unidentified feed chemicals were almost completely consumed. The main products of MEAw degradation were ammonia, VFAs and biogas. The ammonia nitrogen concentration reached about 2.0 g/L, which may explain the observed inhibition of acetoclastic methanogenesis leading to acetate accumulation. Methane accounted for up to 80% of the biogas generated. The highest methane yield was 0.34 L/g-COD while the yield was 0.16 L/g-COD at the highest load. This study shows that more than 80% reclaimer MEAw COD degradation with a co-substrate can be maintained in a hybrid anaerobic bioreactor operated in a wide loading range.


2010 ◽  
Vol 62 (11) ◽  
pp. 2527-2535 ◽  
Author(s):  
S. P. Langevin ◽  
B. Q. Liao

In-mill thermophilic treatment of individual wastewater streams to achieve water system closure has received much attention in pulp and paper mills. Aerobic biological treatment of thermomechanical pulping (TMP) condensate was conducted using thermophilic (55°C) and mesophilic (35°C) sequencing batch reactors (SBRs) for a period of 143 days at a cyclic time of 6, 8 and 12 h. A soluble chemical oxygen demand (SCOD) removal efficiency of 77 to 91% was achieved, given an organic loading rate of 0.7–1.3 kg/m3 d. The COD removal efficiency of the thermophilic SBR was slightly lower than that of the mesophilic SBR. Majority of the soluble COD was removed by biodegradation with a small portion (9–13%) of soluble COD stripped by aeration. The settleability (sludge volume index) and the flocculating ability (effluent suspended solids) of thermophilic sludge were comparable to or slightly poorer than that of the mesophilic sludge. The level of filaments in thermophilic sludge was usually higher than that in mesophilic sludge. The results of the study indicate that both thermophilic and mesophilic SBRs can be successfully operated for in-mill treatment of TMP condensate. The treated effluent has the potential for subsequent reuse in the mill.


2017 ◽  
Vol 43 (3) ◽  
pp. 24-31 ◽  
Author(s):  
Jan Paweł Bogacki ◽  
Hussein Al-Hazmi

AbstractAdvanced automotive fleet repair facility wastewater treatment was investigated with Zero-Valent Iron/Hydrogen Peroxide (Air/ZVI/H2O2) process for different process parameters: ZVI and H2O2doses, time, pH. The highest Chemical Oxygen Demand (COD) removal efficiency, 76%, was achieved for ZVI/H2O2doses 4000/1900 mg/L, 120 min process time, pH 3.0. COD decreased from 933 to 227 mg/L. In optimal process conditions odor and color were also completely removed. COD removal efficiency was increasing with ZVI dose. Change pH value below and over 3.0 causes a rapid decrease in the treatment effectiveness. The Air/ZVI/H2O2process kinetics can be described as d[COD]/dt = −a [COD]tm, where ‘t’ corresponds with time and ‘a’ and ‘m’ are constants that depend on the initial reagent concentrations. H2O2influence on process effect was assessed. COD removal could be up to 40% (560 mg/L) for Air/ZVI process. The FeCl3coagulation effect was also evaluated. The best coagulation results were obtained for 700 mg/L Fe3+dose, that was slightly higher than dissolved Fe used in ZVI/H2O2process. COD was decreased to 509 mg/L.


Sign in / Sign up

Export Citation Format

Share Document