The Application of Computer Simulations on one Commercial Building to Improve Energy Performance

2010 ◽  
Vol 171-172 ◽  
pp. 364-367
Author(s):  
Jia Fang Song

This paper introduces the application of the TAS simulation support software to determine the energy performance in between a full mechanical ventilated building than that of a hybrid ventilated-- combined mechanical and naturally ventilated (atrium area to be naturally ventilated) building. A modeled three-storey commercial office building will be used as the main subject of this analysis. To determine the thermal comfort level of the central atrium, Parameters will be set in such a way that the full height windows will be 100% open. Results will be then tabularized to determine and analysis the output of the simulation. Recommendations will be then given based on the output performance of the building. In Tropics, it’s very difficult to achieve better thermal comfort in a naturally ventilated building. With the help of these simulation tools we can find whether natural ventilation is possible in this tropical climate in terms of thermal comfort, ventilation system and energy demand.

2011 ◽  
Vol 199-200 ◽  
pp. 1505-1508
Author(s):  
Jia Fang Song

In this paper, the simulation software was applied to evaluate a hybrid ventilated combined mechanical and naturally ventilated (atrium area to be naturally ventilated) building. In order to understand the impact of the usage of natural ventilation on thermal comfort in atrium, we utilized TAS to simulate the air temperature and air velocity distribution for the atrium. A modeled three-storey commercial office building was used as the main subject of this analysis. To determine the thermal comfort level of the central atrium, Parameters will be set in such a way that the full height windows will be 100% open. Results were tabularized to determine and analysis the output of the simulation. Recommendations will be then given based on the output performance of the building.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3311
Author(s):  
Víctor Pérez-Andreu ◽  
Carolina Aparicio-Fernández ◽  
José-Luis Vivancos ◽  
Javier Cárcel-Carrasco

The number of buildings renovated following the introduction of European energy-efficiency policy represents a small number of buildings in Spain. So, the main Spanish building stock needs an urgent energy renovation. Using passive strategies is essential, and thermal characterization and predictive tests of the energy-efficiency improvements achieving acceptable levels of comfort for their users are urgently necessary. This study analyzes the energy performance and thermal comfort of the users in a typical Mediterranean dwelling house. A transient simulation has been used to acquire the scope of Spanish standards for its energy rehabilitation, taking into account standard comfort conditions. The work is based on thermal monitoring of the building and a numerical validated model developed in TRNSYS. Energy demands for different models have been calculated considering different passive constructive measures combined with real wind site conditions and the behavior of users related to natural ventilation. This methodology has given us the necessary information to decide the best solution in relation to energy demand and facility of implementation. The thermal comfort for different models is not directly related to energy demand and has allowed checking when and where the measures need to be done.


2019 ◽  
Vol 29 (7) ◽  
pp. 972-986 ◽  
Author(s):  
Xiang Deng ◽  
Zijing Tan

The utilisation of automatic controlled natural wind in office buildings to maintain indoor thermal comfort has gained wide attention in recent years. Generally, it is not necessary to ensure that the whole internal volume of a building with large open spaces meets thermal comfort requirements. Primary focus should be on occupied areas. Accordingly, the local thermal comfort in an open-plan office with automatic controlled natural ventilation system was investigated numerically and experimentally. A computational fluid dynamics (CFD)-based method was presented for indoor environment and thermal comfort prediction. Long-term in situ measurement was conducted during summer and transition seasons. The meteorological data were collected by a mini weather station located on the roof of the target building. Meanwhile, indoor air velocity, temperature, turbulence intensity and wall temperatures were recorded locally. Three thermal comfort indices, i.e. thermal stratification represented by percentage dissatisfied (PD), the extended predicted mean vote (PMVe) and draught rate were employed to evaluate the thermal comfort level of the interested areas during natural ventilation period. The numerical results revealed a risk of local thermal dissatisfaction under low outdoor temperature and strong windy conditions.


2020 ◽  
Vol 3 (1) ◽  
pp. p1
Author(s):  
Jad Hammoud ◽  
Elise Abi Rached

The increasing of energy demands has considerably increased the requirements for new and traditional buildings in different climate zones. Unprecedented heat waves have increased climate temperature, in particular, in moderate climate zones such as Lebanon. In Beirut, only the residential sector consumes 50% of total electricity consumption. HVAC (Heating, Ventilation and Air conditioning) systems are used to reach acceptable thermal comfort levels in the new residential buildings. In case of the traditional bourgeoisie houses in Beirut, there are no discussions about the use of HVAC systems to achieve the required thermal comfort level. Thus, to reach an acceptable thermal comfort level, these houses which already contain natural ventilation system shall adapt the modern thermal comfort requirements and thermal comfort strategies and technologies where their architectural features and existing materials condition the available solutions. In order to identify the best options within the possible intervention lines (envelopes, passive strategies, equipment, renewable energy systems), it is necessary to perceive the real performance of this type of houses. In this context, the article presents the results of the study of thermal performance and comfort in a three case studies located in Beirut. Detailed field data records collected are analyzed, with a view to identify the indoor thermal environment with respect to outdoor thermal environment in different seasons. Monitoring also included measurement of hygrothermal parameters and surveys of occupant thermal sensation.


Author(s):  
Elvire Katramiz ◽  
Nesreen Ghaddar ◽  
Kamel Ghali

Abstract The mixed-mode ventilation (MMV) system is an energy-friendly ventilation technique that combines natural ventilation (NV) with mechanical air conditioning (AC). It draws in fresh air when the outdoor conditions are favorable or activates otherwise the AC system during occupancy hours. To improve performance of the MMV system, it is proposed to integrate it with an intermittent personalized ventilation (IPV) system. IPV delivers cool clean air intermittently to the occupant and enhances occupant thermal comfort. With the proper ventilation control strategy, IPV can aid MMV by increasing NV mode operational hours, and improve the energy performance of the AC system by relaxing the required macroclimate set point temperature. The aim of this work is to study the IPV+MMV system performance for an office space application in terms of thermal comfort and energy savings through the implementation of an appropriate control strategy. A validated computational fluid dynamics (CFD) model of an office space equipped with IPV is used to assess the thermal fields in the vicinity of an occupant. It is then coupled with a transient bio-heat and comfort models to find the overall thermal comfort levels. Subsequently, a building-performance simulation study is performed using Integrated Environmental Solutions-Virtual Environment (IES-VE) for an office in Beirut, Lebanon for the typical summer month of July. An energy analysis is conducted to predict the savings of the suggested design in comparison to the conventional AC system. Results showed that the use of IPV units and MMV significantly reduced the number of AC operation hours while providing thermal comfort.


2016 ◽  
Vol 78 (8-4) ◽  
Author(s):  
Fawaz Ghaleb Noman ◽  
Nazri Kamsah ◽  
Haslinda Mohamed Kamar

A combined natural ventilation and mechanical fans are commonly used to cool the interior space inside the mosques in Malaysia. This article presents a study on thermal comfort in the Al-Jawahir Mosque, located in Johor Bahru, Malaysia. The objective is to assess the thermal comfort inside the mosque under the present ventilation system by determining the Predicted Mean Vote (PMV) and the Predicted Percentage of Dissatisfied (PPD). These values were then compared to the limits stated in the ASHRAE Standard-55. It was found that the PMV varies from 1.68 to 2.26 while the PPD varies from 61% to 87%. These show that the condition inside the mosque is quite warm. Computational fluid dynamics (CFD) method was used to carry out flow simulations, to identify a suitable strategy to improve the thermal comfort inside the mosque. Results of CFD simulations show that installing four exhaust fans above the windows on the west-side wall of the mosque is the most effective strategy to improve the thermal comfort inside the mosque. Both the PMV and PPD values can potentially be reduced by more than 60%.


2020 ◽  
Vol 41 (3) ◽  
pp. 247-260
Author(s):  
Roy Candra Sigalingging ◽  
David Chow ◽  
Steve Sharples

In a hot and humid tropical climate, natural ventilation brings high levels of moisture into dwellings that, together with occupant activity, can result in very elevated internal relative humidity levels. Coupling these high relative humidities with high internal air temperatures creates occupant thermal discomfort, which is typically ameliorated in the tropics using energy-intensive air conditioning systems. This paper has investigated the potential benefits for thermal comfort and energy usage of applying the German Passivhaus standard to tropical dwellings. By creating a super insulated and air-tight envelope, the Passivhaus standard reduces fabric heat transfer, controls air infiltration and provides low-energy comfort. Applying this approach to a tropical terraced house might be effective but could, potentially, have an adverse impact on mechanical cooling demand. This study took an actual terraced property in Jakarta, Indonesia and thermally modelled its performance as insulation and airtightness levels were incrementally improved up to the Passivhaus standard. Field measurements in the dwelling of air temperature and relative humidity were used to validate the thermal model of the existing house. The validated model then tested the feasibility of meeting the Passivhaus energy standard for cooling in the modified tropical house. Simulation allowed the effects of air conditioning (AC) and dehumidifiers on thermal comfort and cooling loads to be investigated. The research develop the Passivhaus building model that had the floor insulation removed to let the ground floor act as a thermal sink and potentially provide radiant cooling. Analysis revealed that the building’s predicted air temperatures were affected in a beneficial way by having the Passivhaus without floor insulation. Practical application: Cooling in hot and humid tropical region is an energy-intensive approach. Design approaches that can bring comfort and save energy for the occupant are essential. The success of Passivhaus standard in mild climate might be transferable to bring comfort in tropical housing. Best practice can be developed by analysing the Passivhaus building performance in hot and humid tropical region.


2020 ◽  
Vol 12 (9) ◽  
pp. 3540 ◽  
Author(s):  
Yuang Guo ◽  
Dewancker Bart

According to a Chinese building energy demand report of 2016, building consumption is accelerating at a spectacular rate, especially for urban public buildings. In this study, various design parameters that meet the principle of climate adaptation are proposed to achieve the unity of energy utilization and indoor thermal comfort level. According to the local energy conservation codes, five typical benchmark geometric models were established in Open Studio (Sketch-Up plug-in) for sites representative of various climates, meanwhile, adopting the engine of Energy Plus (EP-Launch) to calculate the instrument definition file (IDF), respectively, for assessing the coupling relationship between energy consumption as well as thermal comfort. Results implied that based on the time proportion (8760 h) that met the level 1 comfort range, total energy reductions of different Chinese climate regions were different. Among them, the severe cold zone (SCZ—Changchun) and hot summer and cold winter zone (HSCW—Shanghai) appeared to have the greatest energy saving potential with 18–24% and 16–19%, respectively, while the cold zone (CZ—Beijing) and mild zone (MZ—Kunming) approximately equaled 15% and 12–15%, and the saving space of the hot summer and warm winter zone (HSWW—Haikou) appeared relatively low, only around 5–7%. Although the simulation results may be limited by the number of parameter settings, the main ones are under consideration seriously, which is further indication that there is still much room for appropriate improvements in the local public building energy efficiency codes.


2018 ◽  
Vol 49 ◽  
pp. 00025 ◽  
Author(s):  
Tomasz Gaczoł

In the following article the author proposes the solution for a properly functioning natural ventilation system based on the use of supply and exhaust ducts, i.e. by designing a natural balanced ventilation system. The paper is devoted to test results of air flow through natural ventilation supply-exhaust ducts in the rooms located on the lower floor of the building. The simulations conducted in ANSYS Fluent software relate to such issues as: pressure system inside the room and in the exhaust duct, distribution of air temperatures in the room, vector direction of airflow through supplyexhaust ducts and in the analysed room. Three types of solutions were selected for the tests: air inflow into the room through the air intake located at the basement level, air inflow through the window ventilator (although no longer used, this solution can be found in many existing residential buildings) and the natural ventilation system supported with the so-called “solar chimney”. All simulations were conducted with an outdoor temperature of +3 degrees C. The indoor temperature is + 20 degrees C, considered to be the minimum thermal comfort level. In the era of common building sealing, the presented ventilation system may be a good solution that guarantees proper functioning of natural ventilation. In all cases presented, it meets the normative regulations and requirements for the ventilation air stream and the air exchange rate in the room. The paper (first part) describes test results concerning the room located on the lower floor of the building, i.e. with a short supply duct and a 12-meter long exhaust duct.


2019 ◽  
Vol 158 ◽  
pp. 3319-3324 ◽  
Author(s):  
Vincent J.L. Gan ◽  
M. Deng ◽  
Y. Tan ◽  
W. Chen ◽  
Jack C.P. Cheng

Sign in / Sign up