The Optimization Design of the Explosion-Proof Steel Frame Structure Considering the Material Plastic

2011 ◽  
Vol 243-249 ◽  
pp. 160-164
Author(s):  
Ya Ting Zang ◽  
Yong Sheng Zhang

Taking the structure construction cost as the optimized goal, the optimization design is carried on the steel frame structure considering the material plastic, under the explosion load. According to the prevailing steel structure design codes GB50017-2002, the model of steel frame structures is established. The results show that the theory and calculation method is reasonable, which will have a guide in the future.

2010 ◽  
Vol 163-167 ◽  
pp. 600-604
Author(s):  
Ke Dong Tang ◽  
Jian Fu ◽  
Jun Dai ◽  
Peng Zhang ◽  
Rui Feng Yu

According to the finite element analysis of a circulating fluidized bed boiler steel frame structure, the essay concludes to the calculation results of the main steel structure, moreover the structure and the composition of bars are adjusted and optimized which improve the safety of the structure reliability and reduce the volume of steel. All of the above contents have certain reference value on the similar structure.


2021 ◽  
Vol 907 (1) ◽  
pp. 012010
Author(s):  
J Aloysius ◽  
J A Sumito ◽  
D Prayogo ◽  
H Santoso

Abstract Damages resulted from earthquakes are a loss in the economic sector. The structure of multi-story buildings needs an earthquake-proof design with higher performance to reduce such losses. By utilizing the metaheuristic algorithm, this study aims to identify the most compatible brace configuration and profile used in a concentrically braced steel frame structures with minimal total weight and that will meet the safety requirements. This algorithm is suitable owing to the fact that it is able to find solutions to any known optimization problem either through Particle Swarm Optimization (PSO), Symbiotic Organisms Search (SOS), or Differential Evolution (DE). The performance of these algorithms will demonstrated in a form of comparison through a case study of optimizing a 5-span, 6-story steel frame structure. These systems will determine the lightest frame weight, which also correlates to a lower construction cost, without compromising the constraints of SNI 1726:2019, SNI 1727:2020, SNI 1729:2020, and AISC 341-16. Based on the results of data processing, SOS is shown to achieve the highest algorithm performance compared to PSO and DE.


2018 ◽  
Vol 4 (1) ◽  
pp. 27
Author(s):  
Osman Fatih Bayrak ◽  
Seda Yedek ◽  
Muhammet Musab Erdem ◽  
Murat Bikce

Infill walls consisting of materials such as hollow concrete, hollow clay and autoclaved aerated concrete bricks are not only preferred in reinforced concrete buildings but also in steel frame structures. It is a well-known fact that infill walls limit the displacement of frames under horizontal loads. However, they may also bring about certain problems due to being placed randomly in horizontal and discontinuously in vertical directions for some architectural reasons. Moreover, cracks in frame-wall joints are observed in steel frame structures in which ductile behaving steel and brittle behaving infill walls are used together. In this study, the effect of infill walls on steel frames has been investigated. In the steel frame structure chosen for the study, four different situations consisting of different combinations of infill walls have been modeled by using ETABS Software. Later, the pushover analyses have been performed for all the models and their results have been compared. As a result of the analyses done by using the equivalent diagonal strut model, it has been found out that infill walls limit the displacement of steel frames and increase the performance of a structure. However, it has been also determined that in the steel frame structure in which the infill walls have been placed discontinuously in vertical and asymmetrically in horizontal, infill walls may lead to torsional and soft story irregularities. As a result, it is possible to observe cracks in the joints of infill walls and steel frame, the deformation properties of which differ, unless necessary precautions are taken.


2014 ◽  
Vol 1065-1069 ◽  
pp. 1245-1248
Author(s):  
Zhuo Jun Zeng ◽  
Jun Ping Wang ◽  
Yan Xiang Li

This article analysis stairs effect on steel frame structure under seismic loading by using the finite element software MIDAS Gen. Detailed analyzing impact of stairs on the self-vibration period, period ratio, the story drift and other design indexes in designing of the impact under seismic loading. Analysis shows that stairs have great effects on the design index of steel frame structure. Therefore the stair effect must be considered in analysis of structure design and modeling.


2011 ◽  
Vol 255-260 ◽  
pp. 2560-2567
Author(s):  
Peng Bo Zhang ◽  
Yu Ping Sun ◽  
Shi Chun Zhao

Analytical study was conducted to investigate effect of friction dampers on vibration control of steel frame structures. The friction dampers installed in a ten-storey sample frame structure have two levels of fictional resistances. Unlike the conventional friction damper which has one frictional resistance, the friction dampers with variable resistances (VRFD) can apply two levels of frictional resistances, the lower resistance of which is attended to absorb the seismic energy by a moderate earthquake or a strong wind, and the higher one of which is expected to dissipate the seismic energy induced by a severe earthquake. The time-historey analytical results of the sample frame have indicated that the VRFD could not only mitigate the seismic response of the frame structure under a moderate earthquake more effectively than the conventional frictional damper, but also provide the same level of damping effect to the structure under severe earthquake as the conventional one.


Author(s):  
Maurizio De Angelis ◽  
Salvatore Perno ◽  
Anna Reggio ◽  
Gerardo De Canio ◽  
Nicola Ranieri

The present work refers to steel frame structures in industrial plants. A passive isolation system for seismic protection of a considerable equipment, already present on a frame support structure and rigidly constrained to it, is investigated through both numerical simulations (1+1 DOF system) and shaking table tests on a 1:5 scale two-story steel frame structure. The equipment (e.g. a pipeline, a compressor unit, ...) is modelled as a rigid mass. The optimal design is determined by minimizing the dynamic response of the isolated mass. In order to ensure strenght and serviceability, the response of the frame is also monitored.


2014 ◽  
Vol 638-640 ◽  
pp. 244-249
Author(s):  
Ya Bo Wang ◽  
Gao Feng Dou ◽  
Chuan Hao Xi ◽  
Lei Qian ◽  
Han Ting Liu

The types of assembly floor slab member and the present development situation of assembly floor slab standardization at home and abroad is presented in the article, as well as assembly floor slab layout schemes and its advantage and disadvantage is presented, and the assembly floor slab standardization scheme is proposed to promote the application of assembly floor slab in steel frame structures.


2012 ◽  
Vol 256-259 ◽  
pp. 905-910
Author(s):  
Chuan Qing Liu ◽  
Zuo Yun Mei ◽  
Xue Guang Gao

In order to improve the capacity of resistance to progressive collapse for steel frame structures, a new measure, which uses bracing systems to help damaged frame to bridge across the local damage caused by abnormal loads, is presented in this study. The dynamic progressive collapse analysis is carried out to investigate the effect of resistance to progressive collapse in two different cases of column removal. Analytical results show that bracing systems on the top of steel frame structure have obvious effects on collapse prevention. Comparison with the unbraced steel frame structure, fixing bracing system could decrease the vertical displacement of the node corresponding to the top of the removed columns, and reduce the moment peak value at the end section of beams. And after column removal, plastic hinges come into being in the unbraced steel frame, on the other hand, there are no plastic hinges formed in the steel frame with bracing system.


2012 ◽  
Vol 166-169 ◽  
pp. 978-983
Author(s):  
Yanhui Ge ◽  
Guo Su

In order to study the seismic behavior of steel frame structure, based on the verification of the finite element program, two different end-plate connections under monotonic load and cyclic load are analysed with the finite-element software ANSYS, considering geometry, material and status nonlinearity. Some parameters such as height of endplate, array of blot, diameter of blot are analysed to study their effects on the seismic behavior of beam-to-column end-plate connection, the bearing capacity of the joint of the framework, the initial rotation stiffness, the ultimate turning power, power-wasting capacity and ductility. The results show that reasonable connection have better power-wasting capacity and ductility , so it can be applicated in multiple-story steel frame structure.


2011 ◽  
Vol 243-249 ◽  
pp. 6197-6201
Author(s):  
You Liang Fang ◽  
Bing Yin Gao ◽  
Jing Yao Duan

In this paper, different types of steel frame structure under earthquake are adopted as the analyzed object of structural collapse. Seismic waves can be applyed into the structure in form of dynamic acceleration in ANSYS/LS-DYNA. The whole process of earthquake effects on the structure is simulated truly. It is helpful to realize and understand the failure mechanism and space mechanism of the different forms of steel frame structures. This paper can also provide a reference for reinforcement and maintenance of structure and a basis of anti-seism design of structure.