A Calculation Method of the Optimal Initial Steam Pressure of the Power Plant Based on Model Analysis

2012 ◽  
Vol 516-517 ◽  
pp. 824-829
Author(s):  
Ning Zhao ◽  
Ya Mi Chen ◽  
Hui Jie Wang

The shortage of control system for the air-cooling unit is the lack of theoretical guidance and relative operating experience in the selection of operating mode. The mathematical model is built to optimize the initial steam pressure of the air-cooling unit with the method of systemic analysis. Through calculation of air-cooling unit NZK600-16.7/537/537-Ⅰ, the optimal initial steam pressure curves in different work conditions are obtained. The analysis will improve the optimal system-wide control theory of air-cooling power plant. Limitation of the initial steam pressure curve provided by manufactory is also analyzed in this paper.

Author(s):  
J. Jianguo ◽  
G. Varlamov ◽  
K. Romanova ◽  
L. Suxiang ◽  
L. Zhigang

The research is carried out using a mathematical model of conditions and features of condensation processes with the influence of changes in internal and external thermal resistances of working bodies, which occur during contamination of outside and inside metal pipes of heat exchange surfaces of air condenser. capacitor. Particular attention is paid to the selection, detailing and determination of more than twenty basic parameters that characterize the operation of the direct cooling unit of the condensing unit for the summer, the conditions of heat transfer processes between the working bodies taking into account the finned outer surface of elliptical condenser tubes. The results of experiments on the mathematical model are analyzed and the influence of the incoming air velocity and ambient temperature on the output steam pressure in the condenser direct air cooling system within the change of internal and external thermal resistances in the range 0-0.001(m2·K)/W due to cooling tube contamination is determined. air condenser steam turbine installation. Conditions, character and features of influence of thermal resistance of pollution in cooling tubes on steam pressure at an exit from them are defined, the basic factors defining steam pressure at an exit, necessity of the organization of control of thermal resistance of pollution in a pipe during unit operation at variable operating conditions and expediency is substantiated. conducting test studies of operating modes while taking into account the influence of thermal resistance of external and internal pollution on the thermal efficiency of the cooling unit. Studies have shown that at a fixed value of the heat load of the exhaust steam, the pressure of the steam outlet increases with increasing ambient temperature and decreasing the speed of the incoming air.


Author(s):  
Christian Vandervort

The power generation industry is facing unprecedented challenges. High fuel costs combined with an increased penetration of renewable power has resulted in greater demand for high efficiency and operational flexibility. Imperative for a reduced carbon footprint places an even higher premium on efficiency. Power producers are seeking highly efficient, reliable, and operationally flexible solutions that provide long-term profitability in a volatile environment. New generation must also be cost-effective to ensure affordability for both domestic and industrial consumers. Gas turbine combined cycle power plants provide reliable, dispatch-able generation with low cost of electricity, reduced environmental impact, and improved flexibility. GE’s air-cooled, H-class gas turbines (7/9HA) are engineered to achieve greater than 63% net, combined cycle efficiency while delivering operational flexibility through deep, emission-compliant turndown and high ramp rates. The largest of these gas turbines, the 9HA.02, exceeds 64% combined cycle efficiency (net, ISO) in a 1 × 1, single-shaft configuration. In parallel, the power plant has been configured for rapid construction and commissioning enabling timely revenue generation for power plant developers and owners. The HA platform is enabled by 1) use of a simple air-cooling system for the turbine section that does not require external heat exchange and the associated cost and complexity, and 2) use of well-known materials and coatings with substantial operating experience at high firing temperatures. Key technology improvements for the HA’s include advanced cooling and sealing, utilization of unsteady aerodynamic methodologies, axially staged combustion and next generation thermal barrier coating (TBC). Validation of the architecture and technology insertion is performed in a dedicated test facility over the full operating range. As of February 2018, a total of 18 HA power plants have achieved COD (Commercial Operation). This paper will address three topics relating to the HA platform: 1) gas turbine product technology, 2) gas turbine validation and 3) integrated power plant commissioning and operating experience.


2018 ◽  
Author(s):  
P. K. Verma ◽  
A. K. Vishnoi ◽  
Naveen Kumar ◽  
Arun K. Nayak ◽  
G. J. Gorade ◽  
...  

Author(s):  
A. Al Bassam ◽  
Y. M. Al Said

This paper summarizes the experiences with the first gas turbine inlet air cooling project in Saudi Arabia. It will cover the feasibility study, cooling system options, overview, system equipment description, process flow diagram, construction, commissioning, start-up and performance of the project which is currently under commissioning and initial start up at Qassim Central Power Plant (QCPP) owned by Saudi Electric Company (S.E.C.) Central Region Branch.


Author(s):  
Kirill Zaharov ◽  
Aleksey Bal'chugov

It is shown that one of the promising methods of heat exchange intensification in the air-cooling unit is the organization of a fluidized layer.


2021 ◽  
Vol 2057 (1) ◽  
pp. 012004
Author(s):  
Yu A Borisov ◽  
V V Volkov-Muzilev ◽  
D A Kalashnikov ◽  
H S Khalife

Abstract The article discusses the issues of reducing the size of the cooling unit of the antenna of a radar station by improving the gas-dynamic processes occurring in the air-cooling unit. The results of the experimental studies of the gas flow in a plate-fin heat exchanger, being blown by one axial fan are presented. The feasibility of changing the number of axial fans for organizing a more uniform flow around the heat-exchange surfaces has been determined by calculation and theoretical methods. The calculation results are confirmed by experimental studies of the air flow in the segment of the heat exchanger, which is provided by a smaller fan.