Application of Virtual Visualization in Smart Power Distribution System

2012 ◽  
Vol 614-615 ◽  
pp. 1908-1912
Author(s):  
Zhi Gao Liu ◽  
Shou Xiang Wang

With the increasing development of the power system, particularly, with the proposing of smart grid and the applying of distributed generation technology, the traditional geographic information system (GIS) which relies on the tables, graphs, has become more and more difficult to meet the needs of power system equipment management, and planning. Three-dimensional (3D) GIS has developed to meet the requirement appropriately. In this paper, we choose ArcGIS as the development platform, ESRI CityEngine 2011 and Google SketchUp as the 3D modeling software. By combining the virtual reality(VR) technology and image synthesis technology, a 3D power distribution system is established, which realizes the 3D physical simulation of the transmission lines, electrical equipment, power distribution stations, and distributed generators. This methodology provides a new vision for the modernization of the power distribution system management.

2019 ◽  
Vol 217 ◽  
pp. 01020 ◽  
Author(s):  
Margarita Chulyukova ◽  
Nikolai Voropai

The paper considers the possibilities of increasing the flexibility of power distribution systems by real-time load management. The principles of the implementation of special automatic systems for this purpose are proposed. These systems enable some loads of specific consumers of the power distribution system switched to islanded operation to “shift” from the daily maximum to the minimum, which makes some generators available to connect certain essential consumers disconnected earlier by under-frequency load shedding system to the power system. The approach under consideration is illustrated by a power system with distributed generation.


Author(s):  
Zuhaila Mat Yasin ◽  
Izni Nadhirah Sam’ón ◽  
Norziana Aminudin ◽  
Nur Ashida Salim ◽  
Hasmaini Mohamad

<p>Monitoring fault current is very important in power system protection. Therefore, the impact of installing Distributed Generation (DG) on the fault current is investigated in this paper. Three types of fault currents which are single line-to-ground, double line-to-ground and three phase fault are analyzed at various fault locations. The optimal location of DG was identified heuristically using power system simulation program for planning, design and analysis of distribution system (PSS/Adept). The simulation was conducted by observing the power losses of the test system by installing DG at each load buses. Bus with minimum power loss was chosen as the optimal location of DG. In order to study the impact of DG to the fault current, various locations and sizes of DG were also selected. The simulations were conducted on IEEE 33-bus distribution test system and IEEE 69-bus distribution test system. The results showed that the impact of DG to the fault current is significant especially when fault occurs at busses near to DG location.</p>


2013 ◽  
Vol 791-793 ◽  
pp. 1889-1891
Author(s):  
Yan Li Fan ◽  
Qing En Li

The low-voltage distribution system is the key component of the electrical power system. Some analysis and research of the low-voltage distribution system is carried out in this paper, which provides some scientific basis to design the low-voltage distribution system. Firstly, the summarize of low-voltage distribution system is taken. The influence to productions and livings of low-voltage distribution system is introduced. Secondly, the mode of connection and design philosophy of low-voltage distribution system is studied in detail, especially the high-rise buildings low-voltage distribution system is concluded and summarized.


Energies ◽  
2020 ◽  
Vol 13 (18) ◽  
pp. 4826
Author(s):  
Steffen Meinecke ◽  
Leon Thurner ◽  
Martin Braun

Publicly available grid datasets with electric steady-state equivalent circuit models are crucial for the development and comparison of a variety of power system simulation tools and algorithms. Such algorithms are essential to analyze and improve the integration of distributed energy resources (DERs) in electrical power systems. Increased penetration of DERs, new technologies, and changing regulatory frameworks require the continuous development of the grid infrastructure. As a result, the number and versatility of grid datasets, which are required in power system research, increases. Furthermore, the used grids are created by different methods and intentions. This paper gives orientation within these developments: First, a concise overview of well-known, publicly available grid datasets is provided. Second, background information on the compilation of the grid datasets, including different methods, intentions and data origins, is reviewed and characterized. Third, common terms to describe electric steady-state distribution grids, such as representative grid or benchmark grid, are assembled and reviewed. Recommendations for the use of these grid terms are made.


2018 ◽  
Vol 12 (4) ◽  
pp. 244-250 ◽  
Author(s):  
Mohammad Ghiasi

Overall, a power-flow study is a steady-state assessment whose goal is to specify the currents, voltages, and real and reactive flows in a power system under a given load conditions. This paper presents a comparison of common power flow techniques in the Tehran metro power distribution system at the presence of non-linear loads. Moreover, a modelling, simulation and analysis of this power distribution system is implemented with the Electrical Transient Analyser Program (ETAP) software. In this assessment, common power flow techniques including the Newton-Raphson (NR), Fast Decoupled (FD), and Accelerated Gauss-Seidel (AGS) techniques are provided and compared. The obtained results (total generation, loading, demand, system losses, and critical report of the power flow) are analysed. In this paper, we focus on the detailed assessment and monitoring by using the most modern ETAP software, which performs numerical calculations of a large integrated power system with fabulous speed and also generates output reports. The capability and effectiveness of the power flow analysis are demonstrated according to the simulation results obtained with ETAP by applying it to the power distribution system of the Tehran metro. In developing countries such as Iran, off-line modelling and simulation of power grids by a powerful software are beneficial and helpful for the best usage of the electrical energy.


2014 ◽  
Vol 529 ◽  
pp. 511-515
Author(s):  
Han Mei Hu ◽  
Qin Feng Li ◽  
Bo Hong ◽  
Nian Fang

Small current neutral grounding system is widely used in 3~66 kV power distribution system in China. In this power system, the single-phase to-earth fault occurs frequently in distribution, thus how to detect the fault line with great accuracy and high efficiency is an important subject in protective relaying of power system. According to a variety of existing theories of fault line selection for small-current neutral grounding system, this paper presents a new design based on integrated criterion, which has been applied in actual production.