Study on Bridge Pile Load Test Status and Existing Problems

2013 ◽  
Vol 743 ◽  
pp. 35-38
Author(s):  
Xue Feng Zhang ◽  
Qing Ning Li ◽  
Ye Ma

This paper introduced the relative merits and open questions of common methods of pile foundation static load test. And a revolutionizing foundation testing technology ,Statnamic has been introduced in the paper. The Satanamic load test has been developed to meet the construction industrys demand for an accurate and cost-effective method of determing the load bearing capacity of high capacity piles.

Author(s):  
Daehyeon Kim ◽  
Kyemoon Baek ◽  
Kyungho Park

This study aims to improve the shaft with hexagon joints to be a type not requiring welding or bolts in the static load test . In order to evaluate the bearing capacity of helical piles, two sites were selected to conduct pile installation for the field test and the pile load test. For the pile load test, the static pile load test and the dynamic pile load test were carried out, and torque was measured during pile installation for the field test to compare and analyze expected bearing capacity and thus assess the feasibility of the method for estimating the bearing capacity. The field pile load test revealed the bearing capacity of the gravity grout pile was the same or greater than 600kN in the static pile load test in accordance with AC 358 Code. The non-grout pile showed the bearing capacity the same or smaller than 600kN, suggesting gravity grouting is required. Moreover, the field pile load test was used to establish the bearing capacity equation considering the torque in pile installation, and a small number of samples were used to establish the equation which can be used as a basic data.


Different methods have been used to determine the pile bearing capacity such as static equations, dynamic equations, empirical methods (EMs), numerical methods, computer software programs, and the pile static load test, these methods were giving different values for pile bearing capacity. In this paper, three empirical methods (Ems) have been selected (Brinch-Hansen, Chin-Kondner, and Decourt) and (AllPile 6) software (AP) has been applied to determine the capacity load of piles for six cases study of drilled concrete piles with a diameter ranging from 800 mm to 1500mm and embedded length ranged 10.5m to 26m. Four of those six piles are located at Portsudan city near the red seacoast and two piles are located in Khartoum city. The results of the pile bearing capacity (PC) calculations obtained using the above-mentioned different methods were compared with results produced by the pile load test. In all six cases study, the settlement of piles was limited, settlement failure was not reached. The results show that the AllPile 6 (AP) and the three mentioned empirical methods (Ems) gave reasonable piles bearing capacity, the (AP) and (BHM) gave the better result than the CKM and DM. While (DM) gave results similar to results determined using the (CKM). However, it was not preferred to use the (CKM) and (DM), unless the failure settlement has occurred in the pile load test.


2016 ◽  
Vol 8 (5) ◽  
pp. 495-498
Author(s):  
Tautvydas Statkus

In this article jacked pile installation technology and its current processes, altering the base physical and mechanical characteristics are discussed. For the jacked pile static load test simulation Plax 3D software was selected, the opportunities and developments were described. Model building, materials, models, model geometry, finite elements, boundary conditions and assumptions adopted in addressing problems described in detail. Three different tasks formulated and load-settlement dependence a comparison of the results with the experiment given. Conclusions are formulated according to the modeling results. Šiame straipsnyje aptarta spaustinių polių įrengimo technologija ir ją taikant vykstantys procesai, keičiantys pagrindo fizines ir mechanines charakteristikas. Spaustinio polio bandymui statine apkrova modeliuoti pasirinktas PLAXIS 3D programinis paketas ir aprašytos jo galimybės bei raida. Detaliai nupasakotas modelio kūrimas, medžiagų modeliai, modelio geometrija, baigtiniai elementai, kraštinės sąlygos ir priimamos prielaidos sprendžiant problemą. Suformuluoti trys sprendžiami uždaviniai ir apkrovos bei nuosėdžio priklausomybe pateikiamas rezultatų palyginimas su eksperimentu. Atsižvelgiant į modeliavimo rezultatus suformuluotos išvados.


2013 ◽  
Vol 790 ◽  
pp. 227-230
Author(s):  
Jian Feng Su ◽  
Yu Feng Xu

Floor slab static load test is a important method to judge the performance and carrying capacity of the slab. This paper, with the background of a factory frame-structure slab, introduced the testing scheme, the details of the testing process as well as the test results. The testing cases provide a useful reference for the same type of project.


2014 ◽  
Vol 22 (4) ◽  
pp. 1-10 ◽  
Author(s):  
Michal Hoľko ◽  
Jakub Stacho

Abstract The article deals with numerical analyses of a Continuous Flight Auger (CFA) pile. The analyses include a comparison of calculated and measured load-settlement curves as well as a comparison of the load distribution over a pile's length. The numerical analyses were executed using two types of software, i.e., Ansys and Plaxis, which are based on FEM calculations. Both types of software are different from each other in the way they create numerical models, model the interface between the pile and soil, and use constitutive material models. The analyses have been prepared in the form of a parametric study, where the method of modelling the interface and the material models of the soil are compared and analysed. Our analyses show that both types of software permit the modelling of pile foundations. The Plaxis software uses advanced material models as well as the modelling of the impact of groundwater or overconsolidation. The load-settlement curve calculated using Plaxis is equal to the results of a static load test with a more than 95 % degree of accuracy. In comparison, the load-settlement curve calculated using Ansys allows for the obtaining of only an approximate estimate, but the software allows for the common modelling of large structure systems together with a foundation system.


2018 ◽  
Vol 149 ◽  
pp. 02031
Author(s):  
A. K. Alzo’ubi ◽  
Farid Ibrahim

In the United Arab Emirates, Continuous Flight Auger piles are the most widely used type of deep foundation. To test the pile behaviour, the Static Load Test is routinely conducted in the field by increasing the dead load while monitoring the displacement. Although the test is reliable, it is expensive to conduct. This test is usually conducted in the UAE to verify the pile capacity and displacement as the load increase and decreases in two cycles. In this paper we will utilize the Artificial Neural Network approach to build a model that can predict a complete Static Load Pile test. We will show that by integrating the pile configuration, soil properties, and ground water table in one artificial neural network model, the Static Load Test can be predicted with confidence. We believe that based on this approach, the model is able to predict the entire pile load test from start to end. The suggested approach is an excellent tool to reduce the cost associated with such expensive tests or to predict pile’s performance ahead of the actual test.