Electrochemical Investigation of Cyproconazole as Corrosion Inhibitor for Copper in Synthetic Seawater

2013 ◽  
Vol 763 ◽  
pp. 23-27 ◽  
Author(s):  
Ji Liu ◽  
Li Zheng ◽  
Hai Bo Gan ◽  
Huan Liu ◽  
Zhi Hua Tao ◽  
...  

This paper presents the investigation of cyproconazole,namely2-(4-chlorophenyl)-3-cyclopropyl-1-(1H-1,2,4-triazol-1-yl) butan-2-ol,ascorrosion inhibitor for copper in synthetic seawater (3.5% NaCl solution).The inhibition action of cyproconazole on the corrosion of copper was investigated by electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization.The selective desorption of Cyproconazole from copper surface was also studied by the differential polarization curves.EIS indicates that the inhibition formed an adsorption film on copper surface.The inhibition efficiency increases with increasing concentration.Polarization curves show that Cyproconazole acts as mixed-up inhibitor.

MRS Advances ◽  
2019 ◽  
Vol 4 (44-45) ◽  
pp. 2391-2399
Author(s):  
Pablo Martínez Jiménez ◽  
Araceli Espinoza Vázquez ◽  
Francisco Javier Rodríguez Gómez

AbstractDimethylformamide (DMF) has been tested as corrosion inhibitor in a metallic material like API 5LX70 in a corrosive solution of 3% of NaCl and using electrochemical technique as electrochemical impedance spectroscopy. The results showed that 20 ppm is the best concentration to protect the metallic surface of API 5L X70 with η∼ 94%. Hydrodynamic conditions (100 and 1000 rpm) demonstrated that the DMF at different concentration afforded moderate protection against corrosion with inhibition efficiency ∼70%. Finally, the adsorption of this compound follows the Langmuir isotherm with a chemisorption-physisorption process.


2014 ◽  
Vol 960-961 ◽  
pp. 229-233 ◽  
Author(s):  
Li Zheng ◽  
Ji Liu ◽  
Zhi Hua Tao ◽  
Wei He ◽  
Ding Jun Xiao ◽  
...  

This paper is mainly to discuss that myclobutanil as corrosion inhibitor and its corrosion efficiency were evaluated via electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization. The potentiodynamic polarization measurements showed that the inhibition efficiency increases sharply with the increasing of concentration of myclobutanil, and the highest inhibition efficiency of the myclobutanil reached 84.3% at 3.2×10-4 mol/L in 1 mol/L HCl. The result also indicated that myclobutanil belongs to the mixed type inhibitor. The results obtained from EIS measurements are in good agreement with that obtained from potentiodynamic polarization.


2011 ◽  
Vol 311-313 ◽  
pp. 657-661
Author(s):  
Xiao Hong Huang ◽  
Sheng Tao Zhang ◽  
Lian Yue Hu

This paper investigates the Isoniazid as chemical corrosion inhibitors for brass in 3.0% NaCl solution of different pH, employing polarization curves, electrochemical impedance spectroscopy(EIS), weight loss, and SEM. It is found that the inhibition efficiency of Isoniazid enhances with the increasing of the solution pH, from about 71% at pH 6.5 to 92% at pH 10.5. This improvement is attributed to the stronger adsorption of Isoniazid in alkaline solution, to prevent the occuring of the corrosion reaction of brass.


2021 ◽  
Vol 406 ◽  
pp. 265-273
Author(s):  
Hakima Hachelef ◽  
Abdallah Khelifa ◽  
Abderrahim Benmoussat

The behaviour of a corrosion inhibitor based on proplolis extract via an iron alloy immersed in an electrolyte containing ethylene glycol water in NaCl 0.1 M was evaluated by a stationary technique not destructive which is the technique of electrochemical impedance. The diameter of the Nyquist curves increases with the increase of the concentration of propolis extract and it reaches an optimum concentration at 1.25 g / L, the maximum surface coverage percent at this concentration is 71.98% .The activation parameters reveal that the inhibitor molecules on iron surface are absorbed by physisorption and a chimisorption and obey Langmuir isotherm adsorption. These results were supplemented by Scanning electron microscopy (SEM) and (EDX) spectrum of chemical composition. The metal solution interface is simulated as a physical model by using electrochemical impedance spectroscopy (EIS). Keywords: Iron Alloy, Propolis extract, ethylene glycol;, Lamgmuir isotherm, Electrochemical impedance Spectroscopy (EIS).


2012 ◽  
Vol 585 ◽  
pp. 488-492
Author(s):  
Adeeba F. Khan ◽  
Awanikumar P. Patil ◽  
T. Subba Rao

Cu-10Ni alloy suffers accelerated corrosion in sulfide polluted seawater. As an alternative, a new single phased, Cu-28%Zn-5%Ni-5%Mn-2%Fe alloy (hereby referred as CNZ-alloy) is developed and tested for the corrosion resistance in clean and sulfide polluted synthetic seawater. The CNZ-alloy showed better corrosion resistance than the standard Cu-10Ni alloy in both the test solutions i.e. clean and sulfide polluted synthetic seawater with . The results are discussed on the basis of polarization and electrochemical impedance spectroscopy. The better corrosion resistance of CNZ-alloy is attributed to the formation of protective ZnS and MnS2 films.


2019 ◽  
Vol 43 (16) ◽  
pp. 6303-6313 ◽  
Author(s):  
Ambrish Singh ◽  
K. R. Ansari ◽  
M. A. Quraishi ◽  
Savas Kaya ◽  
Priyabrata Banerjee

The corrosion inhibition behavior of a naphthoxazinone derivative 1-phenyl-1,2-dihydronaphtho[1,2-e][1,3]oxazin-3-one (PNO) on J55 steel in 3.5 wt% NaCl solution saturated with carbon dioxide was evaluated using weight loss, electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization.


2017 ◽  
Vol 744 ◽  
pp. 380-384
Author(s):  
Hui Tong ◽  
Wen Li Han ◽  
Zhong Ping Xu ◽  
Yan Jun Zhang ◽  
Zhu Lin ◽  
...  

Electrochemical impedance spectroscopy (EIS) is a technology of nondestructive electrochemical testing. In this paper, EIS is applied to study the corrosion processes of Al-Mg coatings. In the initial 24 h of immersion in 3.5% NaCl solution, passive films of Al-Mg coatings dissolve quickly. As time passed, corrosion products increase on surface gradually, which can inhibit corrosion. After 480h of immersion, corrosion products fully cover on Al-Mg coatings’ surface. The EIS of different corrosion processes are fitted by three equivalent circuits corresponding to the three corrosion processes. In the test of open circuit potentials (OCP), OCP is instable in the initial 24 h of immersion. As immersion time goes by, OCP tends to stabilization at about -0.90 V. Measurements of scanning electron microscope (SEM) confirm the conclusions of electrochemical measurements.


2009 ◽  
Vol 6 (s1) ◽  
pp. S189-S194 ◽  
Author(s):  
N. S. Patel ◽  
S. Jauhari ◽  
G. N. Mehta

Extract ofFicus exasperataleaves was investigated as corrosion inhibitor of mild steel in 1 N H2SO4using conventional weight loss, electrochemical polarizations, electrochemical impedance spectroscopy and scanning electron microscopic studies. The weight loss results showed that the extract ofFicus exasperatais excellent corrosion inhibitor. Electrochemical polarizations data revealed the mixed mode of inhibition. The results of electrochemical impedance spectroscopy shows that the change in the impedance parameters, charge transfer resistance and double layer capacitance, with the change in concentration of the extract is due to the adsorption of active molecules leading to the formation of a protective layer on the surface of mild steel. Scanning electron microscopic studies provided the confirmatory evidence of improved surface condition, due to the adsorption, for the corrosion protection.


2013 ◽  
Vol 652-654 ◽  
pp. 1432-1435
Author(s):  
Qian Hu ◽  
Jing Liu ◽  
Jie Zhang ◽  
Feng Huang ◽  
Xing Peng Guo

The crevice corrosion behaviors of X52 carbon steel in two typical Cl--containing solutions were investigated by electrochemical noise and electrochemical impedance spectroscopy. Results show that oxygen concentration difference leads to the coupled current in NaCl + NaHCO3 solution while HAc concentration difference causes the coupled current in NaCl solution saturated with CO2 in the presence of HAc. There exists an apparent incubation stage during the crevice corrosion process of X52 carbon steel in the former. However, no obvious incubation period of crevice corrosion can be observed in the latter. Micrography shows that the crevice corrosion occurs indeed and the corrosion inside the crevice is not uniform.


Sign in / Sign up

Export Citation Format

Share Document