The Research of Two Staged Non-Isolated Photovoltaic Grid Connected Inverter Control Method

2013 ◽  
Vol 773 ◽  
pp. 139-142
Author(s):  
Jia Guo ◽  
Zhi Gang Li ◽  
Ya Ping Cheng ◽  
Chun Yan Cui

Grid-connected inverter topologies and control methods are analyzed and compared on the basis of two non-isolated PV grid-connected inverter circuit topology as 3kVA grid connected PV systems. In this paper, the current control method, the DC bus voltage outer grid current inner loop of the dual closed-loop PI control method. Sampled signal through the system circuit for processing, resulting in a SPWM drive signal to control the conduction of the power devices off the grid current control.

2011 ◽  
Vol 347-353 ◽  
pp. 591-600
Author(s):  
Nguyen Viet Ngu ◽  
Hong Hua Wang ◽  
Le Thi Minh Tam

The control objective of three-phase photovoltaic (PV) grid-connected inverter is to generate high quality and stable AC sinusoidal output power with the same phase angle, frequency and amplitude compatible with the grid-connected voltage. To overcome the shortcoming of the normal current PWM control method and traditional PI algorithm, this paper researches a combined control strategy of three phase PV grid-connected inverter based on fuzzy PI controller. The combined control strategy switches different PWM current control method among the hysteretic PWM, SVPWM, hysteretic current SVPWM according to the error between command current and feedback current,and the d-axis command current is output of fuzzy PI controller of DC bus voltage. The simulation model of the combined control strategy for three phase PV grid-connected inverter based on normal PI controller is built with Matlab, simulation results verified the combination control strategy based on fuzzy PI controller has excellent performances.


2012 ◽  
Vol 241-244 ◽  
pp. 636-640
Author(s):  
Wu Wu Tang ◽  
Liang Liang Chen ◽  
Hong Xu Yin ◽  
Hao Dong

This paper developed a mathematical model of three-phase PV grid-connected inverter, and studied the grid-connected current control method based on PI control in synchronous rotating reference frame. Simulation and experimental results from the prototype of 30kW three-phase PV grid-connected inverter proved the correctness and the feasibility of the control strategy, and this grid-connected inverter can operate at the unity power factor state with a nice dynamic performance, and the output current has high sinusoidal and low harmonic content as well as good symmetry.


2019 ◽  
Vol 9 (2) ◽  
pp. 252 ◽  
Author(s):  
Ziqian Zhang ◽  
Cihan Gercek ◽  
Herwig Renner ◽  
Angèle Reinders ◽  
Lothar Fickert

This article presents an in-situ comparative analysis and power quality tests of a newly developed photovoltaic charging system for e-bikes. The various control methods of the inverter are modeled and a single-phase grid-connected inverter is tested under different conditions. Models are constituted for two current control methods; the proportional resonance and the synchronous rotating frames. In order to determine the influence of the control parameters, the system is analyzed analytically in the time domain as well as in the frequency domain by simulation. The tests indicated the resonance instability of the photovoltaic inverter. The passivity impedance-based stability criterion is applied in order to analyze the phenomenon of resonance instability. In conclusion, the phase-locked loop (PLL) bandwidth and control parameters of the current loop have a major effect on the output admittance of the inverter, which should be adjusted to make the system stable.


2013 ◽  
Vol 732-733 ◽  
pp. 1261-1264
Author(s):  
Zhi Lei Yao ◽  
Lan Xiao ◽  
Jing Xu

An improved control strategy for three-phase grid-connected inverters with space vector pulse width modulation (SVPWM) is proposed. When the grid current contains harmonics, the d-and q-axes grid currents is interacted in the traditional control method, and the waveform quality of the grid current is poor. As the reference output voltage cannot directly reflect the change of the reference grid current with the traditional control strategy, the dynamic response of the grid-connected inverter is slow. In order to solve the aforementioned problems, the d-and q-axes grid currents in the decoupled components of the grid current controller are substituted by the d-and q-axes reference grid currents, respectively. The operating principles of the traditional and proposed control methods are illustrated. Experimental results show that the grid-connected inverter with the improved control strategy has high waveform quality of the grid current and fast dynamic response.


2013 ◽  
Vol 416-417 ◽  
pp. 962-967
Author(s):  
Qi Feng Liang ◽  
Hong Fei Liao

As people enter the 21st century, energy problems become one of the important restriction factors which have great influence on sustainable development of human society. So how to develop new energy and effectively use new energy is an important problem which we must face. Under the simulation environment of Matlab/Simulink, the simulation model of the whole system is established, simulation experiments are made on the designed main circuit and control system to test the design. In addition, photovoltaic array simulation model is established to test the performance of the system using perturbation observation MPPT control algorithm.


Sign in / Sign up

Export Citation Format

Share Document